22
Align method
:
Include left mark camera,nozzle 1-8,right mark camera,choose the alignment method according to the
actual situation,right side will show the real image by mark camera alignment.
Nozzle Down Test
:
When mark cameras are selected as the alignment mode, this function is gray and inoperable.
When selecting nozzle 1-8, this interface turns black and can be operated. The user must first lock the position, enter a
reasonable height value, and then click the nozzle down test button to measure whether the reclaiming height is
reasonable.
(Note: when locking the interface to test the reclaiming height of feeder, feeder will not open automatically. You can
select the material above the edge of the component to measure.)
Point 1, Point 2, Mid-point
:
This operation is used to select the center position of some components.
For example, select " left mark camera" as alignment mode. First select the center of the first pin of the lower left foot
of the chip, click "point 1", then select the pin center of the upper right foot opposite to left 1, click "point 2", and then
click
the middle point. The machine will automatically calculate the center position of the chip.
Light source
: outer ring,middle ring,Inner ring,Mark point generally select to use outer or inner ring,select
corresponding light source according to PCB kind.
Brightness:
Image recognize brightness can be adjusted on the drop-down list.
6. Coordinate information
6.1 PCB Mark setting
Function: After finishing mark setting, when the machine is working, the specific position and direction of PCB can confirm
via setting mark. Only in this way the next step of mounting work can carry out.PCB mark setting interface see below fig.
Содержание NeoDen10
Страница 1: ...1 NeoDen10 High Speed Pick and Place Machine User Manual ...
Страница 2: ...2 Model NeoDen10 High Speed Pick and Place Machine Version V1 0 ...
Страница 11: ...11 ...