background image

2) Keep machine working under low mist level when room relative humidity is higher than 70% or in an enclosed room space. 

3) Use clean water lower than 40 degree ( pure water is recommended) 

4) Clean water tank and water flume when use again after a long time. 

 

2. 

Operation steps 

1)  Get the water tank out of the machine, unscrew the water tank cover and fill the tank with water, then screw back the water 

tank cover tightly. Put the water tank on the machine base steadily. 

2)  Inspect whether the mist outlet nozzle is put well on the water tank. 

3)  Plug in the power, turn the knob clock wisely ., machine starts to work. To adjust the mist output from minimum to maximum 

by turning the knob clock wisely. To adjust the mist output from maximum to minimum and to turn off the machine by turning 

the knob counter clock wisely.   

4)  When out of water, the indicating light turns red and the machine stops working .Refill the tank then turn on the machine to 

have machine work again. 

5)

 

During the machine working, machine will stop working when take off the tank,put tank the water tank to the machine base, 

machine will continue to work . 

   

 

Cleanness & Maintenance 

 

Before cleaning, turn the functional knob point to “ OFF”, take off the plug  

1) Transducer 

 

The water quality in someplace is too hard so that the transducer surface will be easy to scale fo rmation, The users need to 

clean transducer with cleaning agent . 

Add little cleaning agent on the transducer surface ( More or less depends on the scale ), then infuse water into the sink to  soak 

the sink fully for 10-15 min.

 

Clean with brush until scale disappear.

 

Clean twice with water

 

Don

t clean transducer by any metal or stiffness material or scrape it to avoid any damage

 

2) Water tank inside 

Clean water tank inside and water sink twice per week at least when use machine frequently  

Use soft cloth wipe it when water tank side has scale 

There will be some dirt stick to the tank inside wall, which can be cleaned with soft scour, Clear the scour completely  

Don't put acid, alkalescency, blencher scour into water tank to avoid damage 

3) Water sink inside 

Take out the water in sink, Clean the scale by brush, then wiped by damp cloth

 

Flush it by water

 

Don’t pour water in sink directly when cleaning the water sink inside

 

Don’t use acid scour to wash the water sink inside to avoid damage on transducer

 

(4)Body and water tank outside 

Wipe it with soft cloth, use soft scour when any dirty 

(5) Storage 

Drain out water in tank and body, clean the dirt, wipe out water and airing the machine 

Ensure that no water in the machine and put it to the carton  

Storage the package in dry place 

 

 

 

 

 

 

 

Содержание SP-25W

Страница 1: ...User s Instruction Manual Ultrasonic Humidifier Model SP 25W ...

Страница 2: ...f protection with warning when waterless Automatic shut off protection when take off the water tank Optional demineralization cartridge to prolong useful life Integrated body design for noise suppression super quiet when operating Ceramic glass glaze transducer can resist water scale effectively to prolong useful life Technical Parameters Model SH201 Rated Max Moisture Capacity 300ml h Water Tank ...

Страница 3: ...f the plug 1 Transducer The water quality in someplace is too hard so that the transducer surface will be easy to scale formation The users need to clean transducer with cleaning agent Add little cleaning agent on the transducer surface More or less depends on the scale then infuse water into the sink to soak the sink fully for 10 15 min Clean with brush until scale disappear Clean twice with wate...

Страница 4: ...t it far away from the furniture and electronic appliance The mist spraying from the humidifier should not be face to the furniture and the electronic appliance which directly to avoid being damaged with damp Safety Items Check the voltage carefully to ensure your home power voltage fits the product Ensure the plug exactly inserts to the right socket and only for the plug without others Make sure ...

Страница 5: ...Посібник користувача Ультразвуковий зволожувач Модель SP 25W ...

Страница 6: ...7 Кабель живлення Функція та особливості Регулювання інтенсивності роботи однією кнопкою Функція ароматизації повітря Великий бак для води для зручного очищення вручну Автоматичне вимикання з попередженням при нестачі води Автоматичне вимикання при знятті резервуару для води Картридж для демінералізації щоб продовжити термін служби опція Інтегрований дизайн корпусу для зменшення шумів Керамічна ул...

Страница 7: ...вуару для води Покладіть заповнений резервуар для води на основу приладу робота буде відновлена 3 Догляд та обслуговування Перед очищенням поверніть кнопку керування в положення ВИМК Вимкніть кабель електроживлення 1 Ультразвукова мембрана Якість води в деяких місцях занадто жорстка так що поверхня мембрани може вкриватися шаром накипу В таких випадках користувачам потрібно періодично чистити мемб...

Страница 8: ...е пошкодити 6 Заходи безпеки До початку експлуатації перевірте напругу у побутовій мережі щоб забезпечити її відповідність номінальним параметрам приладів вказаним у технічних характеристиках Переконайтеся що вилка належним чином вставлена у розетку Вмикайте лише у розетку до якої не під єднані інші прилади Переконайтеся якості контакту між вилкою і розеткою Виймаючи мережний шнур з розетки тягніт...

Страница 9: ...ого центру для ремонту Не розбирайте та не складайте пристрій самостійно так ви можете наразитися на небезпеку Цей пристрій не призначається для використання особами включаючи дітей з обмеженими фізичними чутливими або розумовими здібностями які не мають досвіду роботи з такими пристроями до тих пір поки за ними не будуть спостерігати дорослі або поки вони не отримають інструктаж від осіб відповід...

Страница 10: ...ту Міністрів України від 10 березня 2017р 139 Декларації про відповідність можна знайти на сайті www optіm ua у розділі Підтримка Адреса потужностей виробництва Foshan Smillon Electrical Appliance Co Ltd Add 4th Floor the C8 Building New Lighting Source Industrial Base Lucun Shishan Town Nanhai Foshan Guangdong Китай Уповноважений Представник в Україні ТОВ ТОРГОВА КОМПАНІЯ ОПТІМ Україна 03134 м Ки...

Отзывы: