background image

 

WIZORD 2 

Electric Fence Energizer

 

 

 

Installer Manual 

Содержание WIZORD 2

Страница 1: ...WIZORD 2 Electric Fence Energizer Installer Manual ...

Страница 2: ...nting Battery Replacement 5 Connection to the Fence 6 Connections Configuration Diagram 7 PC Board Replacement Procedures 8 Service Conditions 9 Appendix 10 Installation notes 13 IEC Safety Information 14 Document revision history 14 Table of Contents 2 ...

Страница 3: ...azards See APPENDIX at the end of this manual and warn the user to avoid head contact with the fence DISCLAIMER NEMTEK Holdings Pty Ltd or any of its subsidiary companies does not guarantee that the operation of the product will be uninterrupted or totally error free Energizer specifications may be altered without prior notification The installer is referred to the definitions and general requirem...

Страница 4: ...h Africa CAPE TOWN Tel 27 0 21 386 3742 27B Concord Crescent Airport City Fax 27 0 21 386 5573 Cape Town South Africa NELSPRUIT Tel 27 0 13 752 2187 Waterval Ave Riverside Industrial Fax 27 0 13 752 2188 Nelspruit South Africa KWAZULU NATAL Tel 27 0 31 701 2125 19 Henwood Road Fax 27 0 31 701 2125 Pinetown South Africa AUSTRALIA Tel 08 9303 9855 Unit 5 19 Innovation Circuit Email nemtek bigpond ne...

Страница 5: ...t Insert the plastic sleeve of the nail in anchor into the wall then hammer the screw in with a screwdriver and hammer NB Always insert the plastic sleeve from the inside of the box STEP 5 Insert battery with the positive terminal to the top STEP 6 Place the battery bracket back with plastic offsets at the top and fasten the screws into place STEP 7 Connect battery wires Close the lid by hooking t...

Страница 6: ...fications OPTION 2 EARTH LOOP MONITORING GOOD SOIL EARTHING This earth wire is not coupled to the fence earth at any other point OPTION 3 EARTH LOOP MONITORING POOR SOIL EARTHING Earth wire connection Live wire connection Earth wire connection Live wire connection Earth wire connection Live wire connection Earth spikes as per SANS 10222 3 or local specifications ...

Страница 7: ...n only Panic Alarm out out out Switched Input instantaneous panic alarm with energizer On or Off High Low Voltage Mode in in out Switched Input toggles the energizer between High Voltage and Low Voltage mode Remote On Off out out in Switched Input acts as remote On Off switch Remote On Off indication and Gate alarm in out in Strobe indicates fence is On or Off Switched Input delayed for 4 minutes ...

Страница 8: ...ove connections are on the back side of the PC Board REPLACEMENT STEP 5 Gently push PC Board back into place Take care that the spade connectors are correctly positioned before pushing the PC Board into place Also ensure that the opto coupler looks like LED is correctly positioned before pushing the PC Board into place STEP 6 Reconnect all connectors to the PC Board STEP 8 Reconnect the battery te...

Страница 9: ...2 AMPERE FAST BLOW SUPPLY The power LED does not illuminate when the mains power is present AUX The siren and strobe does not function BATTERY The energizer switches off in the absence of mains power FUSE DESCRIPTION FAULT SYMPTOMS SUPPLY BATTERY AUX ...

Страница 10: ...arated from pulse conductors below 1 5m by a physical barrier General requirements for electric security fences Electric fences shall be installed and operated so that they cause no electrical hazard to persons animals or their surroundings Electric fence constructions which are likely to lead to the entanglement of animals or persons shall be avoided as entrapment can be lethal An electric fence ...

Страница 11: ...e ground to a depth of at least 1m The distance between any electric security fence earth electrode and other earth systems shall not be less than 2m Connecting leads that are run inside buildings shall be effectively insulated from the earthed structural parts of the building This may be achieved by using insulated high voltage cable Connecting leads that are run underground shall be run in a con...

Страница 12: ...s and reduces the risk of persons receiving an electric shock unless they attempt to penetrate the physical barrier or are in a secure area without authority Exposed conductive parts of the physical barrier shall be effectively earthed A spacing of 2 5 m shall be maintained between uninsulated electric fence conductors or uninsulated connecting leads supplied from different energizers This spacing...

Страница 13: ... conduit or through the same hole as the low voltage wiring Always use ferrules or line clamps to connect two high voltage wires together Avoid using dissimilar materials for connections like copper on steel The fence must be earthed properly with three earth electrodes close to the energizer The distance between the fence earth electrode and any other earth systems shall be not less than 2m for a...

Страница 14: ...ded for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Electric fencing can be lethal Avoid head contact with the fence Ask the installer to explain the options of current limiting resistors Rev 1...

Отзывы: