background image

 

Introduction & Company Profile  

 

 

 

 

 

 3 

Guarantee  

 

 

 

 

 

 

 

 

 

 4 

Nemtek Group Outlets  

 

 

 

 

 

 

 

 5 

Symbol Key 

  

 

 

 

 

 

 

 

 

 6 

Energizer Details & Mounting    

 

 

 

 

 

 7 

Energizer Features    

 

 

 

 

 

 

 

 8 

Product Specifications  

 

 

 

 

 

 

 

 9 

Operating the Energizer    

 

 

 

 

 

 

 10 

Using the Nemtek Tag  

 

 

 

 

 

 

 

 10 

Installation Notes 

  

 

 

 

 

 

 

 

 12 

Appendix   

 

 

 

 

 

 

 

 

 

 13 - 16 

Document Revision History  

 

 

 

 

 

 

 17 

 

AGRI Solar 

Table of Contents 

 

General requirements for electric fences 

 

Electric fences shall be installed and operated so that they cause no electrical hazard to persons, animals or 
their surroundings. 
 
Electric fence constructions which are likely to lead to the entanglement of animals or persons shall be 
avoided. 
 
An electric fence shall not be supplied from two different energizers or from independent fence circuits of the 
same energizer. 
 
For any two different electric fences, each supplied from a different energizer with independent timing, the 
distance between the wires of the two electric fences shall be at least 2.5m. If this gap is to be closed, this 
shall be affected by means of electrically nonconductive material or an isolated metal barrier. 
 
Barbed wire or razor wire shall not be electrified by an energizer. 
 
Electric fences and their ancillary equipment shall be installed, operated and maintained in a manner that 
minimizes danger to persons, and reduces the risk of persons receiving an electric shock unless they attempt 
to penetrate the physical barrier, or are in a secure area without authority. Exposed conductive parts of the 
physical barrier shall be effectively earthed. 
 
A spacing of 2.5m shall be maintained between non insulated electric fence conductors or non insulated 
connecting leads supplied from different energizers. This spacing may be less where conductors or 
connecting leads are covered by insulating sleeving, or consist of insulated cables, rated to at least 10kV. 
 
This requirement need not apply where the separately energized conductors are separated by a physical 
barrier, which does not have any openings greater than 50mm. 
 
A vertical separation of not less than 2m shall be maintained between pulsed conductors fed from different 
energizers. 
 
Ensure that all ancillary equipment connected to the electric fence circuit provides a degree of isolation 
between the fence circuit and the supply mains equivalent to that provided by the energizer. Protection from 
the weather shall be provided to the ancillary equipment unless this equipment is certified by the 
manufacturer as being suitable for use outdoors, and is of a type with a minimum degree of protection IPx4. 
 
Connecting leads that are run inside buildings shall be effectively insulated from the earthed structural parts 
of the building. This may be achieved by using insulated high voltage cable. 
 
Connecting leads that are run underground shall be run in a conduit of insulating material or else insulated 
high voltage cable shall be used. Care shall be taken to avoid damage to the connecting leads due to 
external factors. 
 
Connecting leads shall not be installed in the same conduit as the mains supply wiring, communication cables 
or data cables. 

AGRI Solar 

 

Appendix 

14 

 

General requirements for electric fences 

 

Electric fences shall be installed and operated so that they cause no electrical hazard to persons, animals or 
their surroundings. 
 
Electric fence constructions which are likely to lead to the entanglement of animals or persons shall be 
avoided. 
 
An electric fence shall not be supplied from two different energizers or from independent fence circuits of the 
same energizer. 
 
For any two different electric fences, each supplied from a different energizer with independent timing, the 
distance between the wires of the two electric fences shall be at least 2.5m. If this gap is to be closed, this 
shall be affected by means of electrically nonconductive material or an isolated metal barrier. 
 
Barbed wire or razor wire shall not be electrified by an energizer. 
 
Electric fences and their ancillary equipment shall be installed, operated and maintained in a manner that 
minimizes danger to persons, and reduces the risk of persons receiving an electric shock unless they attempt 
to penetrate the physical barrier, or are in a secure area without authority. Exposed conductive parts of the 
physical barrier shall be effectively earthed. 
 
A spacing of 2.5m shall be maintained between non insulated electric fence conductors or non insulated 
connecting leads supplied from different energizers. This spacing may be less where conductors or 
connecting leads are covered by insulating sleeving, or consist of insulated cables, rated to at least 10kV. 
 
This requirement need not apply where the separately energized conductors are separated by a physical 
barrier, which does not have any openings greater than 50mm. 
 
A vertical separation of not less than 2m shall be maintained between pulsed conductors fed from different 
energizers. 
 
Ensure that all ancillary equipment connected to the electric fence circuit provides a degree of isolation 
between the fence circuit and the supply mains equivalent to that provided by the energizer. Protection from 
the weather shall be provided to the ancillary equipment unless this equipment is certified by the 
manufacturer as being suitable for use outdoors, and is of a type with a minimum degree of protection IPx4. 
 
Connecting leads that are run inside buildings shall be effectively insulated from the earthed structural parts 
of the building. This may be achieved by using insulated high voltage cable. 
 
Connecting leads that are run underground shall be run in a conduit of insulating material or else insulated 
high voltage cable shall be used. Care shall be taken to avoid damage to the connecting leads due to 
external factors. 
 
Connecting leads shall not be installed in the same conduit as the mains supply wiring, communication cables 
or data cables. 

AGRI Solar 

 

Appendix 

14 

Содержание Strainrite AGRI Solar

Страница 1: ...security and perimeter control systems and have been involved in the security industry since 1990 We have our own research and development team designing and manufacturing a full range of globally competitive electric fence energizers and related products NEMTEK is continually updating its products according to South African and international standards in order to ensure the highest quality produc...

Страница 2: ...up Outlets 5 Symbol Key 6 Energizer Details Mounting 7 Energizer Features 8 Product Specifications 9 Operating the Energizer 10 Using the Nemtek Tag 10 Installation Notes 12 Appendix 13 16 Document Revision History 17 AGRI Solar Table of Contents 2 3 4 5 6 7 8 9 10 10 12 13 16 Introduction Company Profile Guarantee Strainrite Fencing Systems Symbol Key Energizer Details Mounting Energizer Features...

Страница 3: ...tribute intelligent electronic agricultural fencing systems security and perimeter control systems and have been involved in the security industry since 1990 We have our own research and development team designing and manufacturing a full range of globally competitive electric fence energizers and related products NEMTEK is continually updating its products according to South African and internati...

Страница 4: ...any other legal theory The foregoing guarantee is in lieu of any and all other guarantees whether expressed implied or statutory including but not limited to warranties of merchantability and suitability for a particular purpose AGRI Solar Guarantee 4 GUARANTEE This energizer manufactured by IO Tech Manufacturing Pty Ltd is guaranteed for a period of two years from date of sale against defects due...

Страница 5: ...eration of the energizer AGRI Solar Introduction Company Profile 3 Head Office Address Tel 64 4 524 9027 81 Montgomery Crescent Email sales strainrite co nz Clouston Park Upper Hutt 5018 Wellington New Zealand Export export strainrite co nz POWERED BY NEMTEK Strainrite is proud to bring to the market an energizer range powered by Nemtek A world leading manufacturer of agriculture and security ener...

Страница 6: ...ion History 17 AGRI Solar Table of Contents 2 AGRI Solar Symbol Key 6 Symbols on the energizer body Represents the Nemtek Tag target Represents fence earth connection terminal Represents fence live connection terminal Represents power from solar panel AGRI Solar Symbol Key 6 Symbols on the energizer body Represents the Nemtek Tag target Represents fence earth connection terminal Represents fence l...

Страница 7: ...ral fencing systems security and perimeter control systems and have been involved in the security industry since 1990 We have our own research and development team designing and manufacturing a full range of globally competitive electric fence energizers and related products NEMTEK is continually updating its products according to South African and international standards in order to ensure the hi...

Страница 8: ...zzer beeps when using Nemtek Tag Internal solar regulator Internal long life eco friendly battery Nemtek Tag Used to toggle the energizer active state on off Used to toggle the energizer between high and low power modes AGRI Solar Energizer Features 8 Robust weather resistant housing Power status indication BATTERY green charged red low yellow in between Pulse rate and power level indicator ENERGI...

Страница 9: ... 1 3 5 8 Battery 12 8V 12 8V 12 8V 12 8V Power consumption 111mW 265mW 420mW 625mW Output energy into 500ohm 0 1J 0 25J 0 45J 0 66J Maximum fence voltage 10kV 10kV 10kV 10kV Environmental rating IP65 IP65 IP65 IP65 Maximum fence length optimal fence 1km 3km 5km 8km Recommended PV panel 5W 5W 10W 10W Open circuit voltage max 23V Note All specifications and recommendations based on 1 5 second pulse ...

Страница 10: ...disconnect the battery after a short period of time and can be stored away in this state The battery will automatically get reconnected when solar power is available or the Nemtek tag is presented to the energizer AGRI Solar Operating the Energizer 10 Present the Nemtek Tag Supplied with the energizer Operating the energizer is straightforward Once the energizer is turned on it will pulse the fenc...

Страница 11: ...ble beep when turning off To toggle the low high power operating state of the energizer keep presenting the tag after the initial detection beep After about 1 5 second has passed a long beep will be emitted The tone of this long beep will be low if the energizer has switched to low power mode or high if the energizer has switched to high power mode Once active the ENERGIZER LED will pulse green if...

Страница 12: ...typically a suburban property installation and 10m for an agricultural fence installation typically a rural property installation Refer to the applicable laws concerning the installation of electric fences in your area AGRI Solar Installation Notes 12 Keep the fence separate from the battery wiring Do not try and modify the energizer Any unauthorized modifications will null and void the warranty a...

Страница 13: ...er which includes one or more electric conductors insulated from earth to which electric pulses are applied by an energizer Connecting Lead An electric conductor used to connect the energizer to the electric fence or the earth electrode Electric animal fence An electric fence used to contain animals within or exclude animals from a particular area Public Access Area Any area where persons are prot...

Страница 14: ...e cable shall be used Care shall be taken to avoid damage to the connecting leads due to external factors Connecting leads shall not be installed in the same conduit as the mains supply wiring communication cables or data cables AGRI Solar Appendix 14 General requirements for electric fences Electric fences shall be installed and operated so that they cause no electrical hazard to persons animals ...

Страница 15: ...e power line and as nearly as possible at right angles to it If connecting leads and electric fence wires are installed near an overhead power line the clearances shall not be less than those shown in the table below Power Line Voltage Clearance Equal or less than 1kV 3 meter Greater than 1kV but equal or less than 33kV 4 meter Greater than 33kV 8 meter If connecting leads and electric fence wires...

Страница 16: ...capacity Once the standby time of the energizer is no longer sufficient return the unit to an authorised Nemtek dealer for replacement of the battery Please dispose of this energizer in an eco friendly way at the end of its life AGRI Solar Appendix 16 Warning There are no serviceable parts inside the energizer This appliance is not intended for use by persons including children with reduced physic...

Страница 17: ...curity and perimeter control systems and have been involved in the security industry since 1990 We have our own research and development team designing and manufacturing a full range of globally competitive electric fence energizers and related products NEMTEK is continually updating its products according to South African and international standards in order to ensure the highest quality products...

Отзывы: