NEFF DWB9 Series Скачать руководство пользователя страница 13

Installation instructions

 en

13

Connect the appliance to a power supply
with alternating current only via a properly
installed socket with earthing.

The protective conductor system of the do-
mestic electrical installation must be prop-
erly installed.

Never equip the appliance with an external
switching device, e.g. a timer or remote
control.

When the appliance is installed, the mains
plug of the power cord must be freely ac-
cessible. If free access is not possible, an
all-pole isolating switch must be installed in
the permanent electrical installation accord-
ing to the conditions of Overvoltage Cat-
egory III and according to the installation
regulations.

When installing the appliance, check that
the power cable is not trapped or dam-
aged.

13.5 General information

Follow these general instructions during the installation.

¡

For the installation, observe the currently valid build-
ing regulations and the regulations of the local elec-
tricity and gas suppliers.

¡

When discharging the exhaust air, the official and
legal regulations, such as the regional building
code., must be observed.

¡

In order to freely access the appliance for servicing,
select an easy-to-reach installation site.

¡

The surfaces of the appliance are sensitive. Avoid
damaging them during installation.

13.6 Instructions for the electrical
connection

In order to safely connect the appliance to the elec-
trical system, follow these instructions.

WARNING ‒ Risk of electric shock!

It must always be possible to disconnect the appliance
from the electricity supply. The appliance must only be
connected to a protective contact socket that has been
correctly installed.

The mains plug for the mains power cable must be
easily accessible after the appliance is installed.

If this is not possible, an all-pole isolating switch
must be integrated into the permanent electrical in-
stallation according to the conditions of overvoltage
category III and according to the installation regula-
tions.

The permanent electrical installation must only be
wired by a professional electrician. We recommend
installing a residual-current circuit breaker (RCCB)
in the appliance's power supply circuit.

Sharp-edged components inside the appliance may
damage the connecting cable.

Do not kink or trap the connecting cable.

¡

The connection data can be found on the rating
plate. → 

Page 9

¡

The connecting cable is approx. 1.30 m long.

¡

This appliance complies with the EC interference
suppression regulations.

¡

The appliance corresponds to protection class 1.
You should therefore only use the appliance with a
protective earth connection.

¡

Do not connect the appliance to the power supply
during installation.

¡

Ensure that the protection against contact is guaran-
teed during installation.

13.7 Information on the installation situation

¡

Install this appliance on the kitchen wall.

¡

To install additional special accessory parts, ob-
serve the enclosed installation instructions.

¡

The appliance must be installed with no more than
one side directly next to a tall unit, an upper cabinet
or a wall. The distance between the appliance and
the tall cabinet, upper cabinet or the wall must be at
least 50 mm.

¡

The width of the extractor hood must correspond at
least with the width of the hob.

¡

To optimally detect the cooking vapours, install the
appliance in the middle of the hob.

13.8 Instructions for the exhaust air pipe

The appliance manufacturer does not provide any war-
ranty for faults attributable to the pipeline.

¡

Use a short, straight exhaust air pipe with as large a
pipe diameter as possible.

¡

Long, rough exhaust air pipes, many pipe bends or
small pipe diameters reduce the suction power and
increase the fan noise.

¡

Use an exhaust pipe that is made of non-combust-
ible material.

¡

To prevent condensate from returning, fit the ex-
haust pipe with a 1° gradient from the appliance.

13.9 Instructions for the air extraction mode

For air extraction mode, a one-way flap should be in-
stalled.

Notes

¡

If a one-way flap is not included with the appliance,
one can be ordered from a specialist retailer.

¡

If the exhaust air is conveyed through the external
wall, a telescopic duct should be used.

13.10 Installation

Checking the wall

1.

Check whether the wall is vertical and has sufficient
load-bearing capacity.
The maximum weight of the appliance is 40 kg.

2.

Drill the hole depth in accordance with the length of
the screws.

3.

Use the enclosed screws and wall plugs.
The enclosed screws and wall plugs are suitable for
use with solid brickwork. Use suitable fixing material
for other structures, e.g. plasterboard, porous con-
crete, poroton bricks.

Содержание DWB9 Series

Страница 1: ...Register your new device on MyBosch now and get free benefits bosch home com welcome Extractor hood DWB9 DWB7 DWB6 DWQ9 DWQ6 DWG9 DWG6 DWA9 DWA6 en User manual and installation instructions...

Страница 2: ...ely and have understood the resulting dangers Do not let children play with the appliance Children must not perform cleaning or user maintenance unless they are at least 15 years old and are being sup...

Страница 3: ...t during operation Allow the appliance to cool down before cleaning WARNING Risk of injury Components inside the appliance may have sharp edges Carefully clean the appliance interior Items placed on t...

Страница 4: ...off the protective film Remove the protective film from all parts of the ap pliance before using for the first time Painted surfaces are easily damaged Follow the cleaning instructions Cleaning the a...

Страница 5: ...f the exhaust air is conveyed through the external wall a tele scopic duct should be used 4 2 Air recirculation The air which is drawn in is cleaned by the grease fil ters and an odour filter and conv...

Страница 6: ...ing off intensive mode Press or 7 6 Switching on the lighting The lighting can be switched on and off independently of the ventilation system Press Cleaning and servicing 8 Cleaning and servicing To k...

Страница 7: ...g the cleaning agents Cleaning products Page 7 2 Clean using a damp sponge cloth and hot soapy water 3 Dry with a soft cloth 8 4 Removing the grease filter 1 ATTENTION Falling grease filters may damag...

Страница 8: ...ing after sales service This will avoid unnecessary costs WARNING Risk of injury Improper repairs are dangerous Repairs to the appliance should only be carried out by trained specialist staff If the a...

Страница 9: ...of your appliance The contact details for Customer Service can be found in the enclosed Customer Service directory or on our website 11 1 Product number E Nr and production number FD You can find the...

Страница 10: ...tion instructions 10 13 1 Scope of delivery After unpacking all parts check for any damage in transit and completeness of the delivery 13 2 Appliance dimensions You will find the dimensions of the app...

Страница 11: ...eric pressure Toxic gases from the chimney or the extrac tion shaft are sucked back into the living space Always ensure adequate fresh air in the room if the appliance is being operated in exhaust air...

Страница 12: ...tall unit an upper cabinet or a wall The dis tance between the appliance and the tall cabinet an upper cabinet or the wall must be at least 50 mm WARNING Risk of injury Components inside the applianc...

Страница 13: ...he appliance may damage the connecting cable Do not kink or trap the connecting cable The connection data can be found on the rating plate Page 9 The connecting cable is approx 1 30 m long This applia...

Страница 14: ...s or water pipes in the area where holes are to be drilled 2 Mark a vertical centre line on the wall from the ceil ing to the lower edge of the appliance 3 Mark the positions for the screws and the co...

Страница 15: ...ipe to the air pipe connector 2 Establish the connection to the exhaust air opening 3 Seal the joints Establishing the exhaust air connection exhaust pipe 120 mm diameter 1 Secure the reducing connect...

Страница 16: ...e left and right hand sides of the retain ing bracket 7 Engage the flue duct section downwards 8 Screw the flue duct section to the sides of the re taining bracket using two screws 9 Use two screws to...

Страница 17: ......

Страница 18: ......

Страница 19: ......

Страница 20: ...ng for help You ll find it here Expert advice for your Bosch home appliances help with problems or a repair from Bosch experts Find out everything about the many ways Bosch can support you www bosch h...