NEFF D96IMV1N0 Скачать руководство пользователя страница 15

Installation instructions

 en

15

16.2 Appliance dimensions

You will find the dimensions of the appliance here

16.3 Safety clearances

Comply with the safety clearances for the appliance.

For Australia and New Zealand the minimum safety

clearance above electrical cooktops must be 600 mm.

 16.4 Secure installation

Follow these safety instructions when in-

stalling the appliance.

WARNING ‒ Risk of poisoning!

Risk of poisoning from flue gases being

drawn back in. Room-air-dependent heat-pro-

ducing appliances (e.g. gas, oil, wood or coal-

operated heaters, continuous flow heaters or

water heaters) obtain combustion air from the

room in which they are installed and dis-

charge the exhaust gases into the open

through an exhaust gas system (e.g. a chim-

ney). With the extractor hood switched on, air

is extracted from the kitchen and the adjacent

rooms. Without an adequate supply of air, the

air pressure falls below atmospheric pressure.

Toxic gases from the chimney or the extrac-

tion shaft are sucked back into the living

space. 

Always ensure adequate fresh air in the

room if the appliance is being operated in

exhaust air mode at the same time as a

room-air-dependent heat-producing appli-

ance is being operated.

It is only possible to safely operate the ap-

pliance if the pressure in the room in which

the heating appliance is installed does not

fall below 4 Pa (0.04 mbar). This can be

achieved whenever the air needed for com-

bustion is able to enter through openings

that cannot be sealed, for example in

Содержание D96IMV1N0

Страница 1: ...Extractor hood User manual and installation instructions D95FMV1N0 D95FMW1N0 D96IMW1N0 D96IMV1N0 D96IKW1S0B D96IKW1S0...

Страница 2: ...en suring that the appliance works perfectly at its installation location Only use this appliance For extracting cooking vapour in private households and in enclosed spaces in a domestic environment u...

Страница 3: ...ration is possible if the ap pliance is operated exclusively in circulat ing air mode WARNING Risk of fire Fatty deposits in the grease filters may catch fire Never operate the appliance without a gre...

Страница 4: ...ower cord or switch off the fuse in the fuse box Call customer services Page 12 Improper repairs are dangerous Repairs to the appliance should only be carried out by trained specialist staff Only use...

Страница 5: ...n speed in good time The odours are distributed around the room less Switch off the lighting if it is no longer required When the lighting is switched off it does not con sume any energy Clean or repl...

Страница 6: ...at ing status Switching the appliance on or off Switching noise reduction on or off Switching the AirFresh function on or off Switching the fan run on on or off Decreasing the fan setting Increasing t...

Страница 7: ...switched off 7 10 Switching on automatic mode The optimum fan setting is set automatically using a sensor Press 7 11 Switching off automatic mode Press a The ventilation is automatically ended when th...

Страница 8: ...ur ap pliance to a mobile device lets you control its functions via the Home Connect app adjust its basic settings and monitor its operating status The Home Connect services are not available in every...

Страница 9: ...connect com 8 6 Data protection Please see the information on data protection The first time your appliance is registered on a home network connected to the Internet your appliance will transmit the f...

Страница 10: ...de the appliance may have sharp edges Carefully clean the appliance interior If the appliance is operated by another person via the Home Connect app during cleaning this increases the risk of injury B...

Страница 11: ...g agents Cleaning products Page 9 2 Soak the grease filter in hot soapy water Use special grease solvent for stubborn dirt You can obtain grease solvents from customer service or the online shop 3 Use...

Страница 12: ...na tion does not work The control unit is faulty Call Customer Service Page 12 Home Connect is not working properly Different causes are possible Go to www home connect com The hob based hood control...

Страница 13: ...dard circulated air set angled canopy hood Z51AIU0X0 Standard no flue circu lated air set angled can opy hood Z51AIT0X0 Standard odour filter re placement angled can opy hood Z51AIA0X0 Long Life circu...

Страница 14: ...model identi fier group is seen on the title page The full model iden tifier is made up of the characters before the slash in the product number E no which can be found on the rating plate Alternativ...

Страница 15: ...led and dis charge the exhaust gases into the open through an exhaust gas system e g a chim ney With the extractor hood switched on air is extracted from the kitchen and the adjacent rooms Without an...

Страница 16: ...sparks The specified safety clearances must be complied with in order to prevent a build up of heat Observe the specifications for your cooking appliances If the installation instructions for the cook...

Страница 17: ...he local elec tricity and gas suppliers When discharging the exhaust air the official and legal regulations such as the regional building code must be observed In order to freely access the appliance...

Страница 18: ...solid brickwork Use suitable fixing material for other structures e g plasterboard porous con crete poroton bricks 4 Install the appliance with a fixing material which is sufficiently stable and has...

Страница 19: ...mm Establishing the exhaust air connection exhaust pipe 150 mm diameter 1 Secure the exhaust pipe to the air pipe connector 2 Establish the connection to the exhaust air opening 3 Seal the joints Esta...

Страница 20: ...er te GmbH Carl Wery Stra e 34 81739 M nchen GERMANY 9001641342 9001641342 040212 en Valid within Great Britain Imported to Great Britain by BSH Home Appliances Ltd Grand Union House Old Wolverton Roa...

Отзывы: