    Installation

14

Attaching and aligning the appliance

1.

First, remove the protective foil from the back of the 

appliance and, following installation, remove the foil 

completely.

2.

When attaching the appliance, ensure that it 

engages firmly with the brackets. 

«

3.

Align the appliance horizontally by turning the 

brackets. If required, the appliance can be moved to 

the right or left. 

¬

4.

Firmly tighten the screws for the brackets. When 

doing so, hold the brackets securely in place. 

®

5.

Firmly tighten the knurled nuts. 

¯

Connecting the pipes

Note: 

If using an aluminium pipe, smooth the 

connection area beforehand.

Exhaust-air pipe Ø 150 mm (recommended size)

Attach the exhaust-air pipe directly to the air-pipe 

connector and seal.

Exhaust-air pipe Ø 120 mm

1.

Attach the reducing connector directly to the air-pipe 

connector.

2.

Attach the exhaust air pipe to the reducing 

connector. 

3.

Seal both joints appropriately.

Attaching the flue duct

:

Warning

Risk of injury!

From sharp edges during installation. Always wear 

protective gloves while installing the appliance.

1.

Separate the flue ducts. 

To do this, remove the adhesive tape.

2.

Remove the protective foil from both flue ducts.

3.

Push one flue duct into the other.

Notes

– To prevent scratches, lay paper over the edges of 

the lower flue duct to protect the surface.

– Slots of the inner flue duct point downwards.

4.

Place flue ducts on the appliance.

5.

Push the inner flue duct upwards and attach it to the 

fixing brackets on the left and right. 

¨

6.

Press the flue duct downwards until it engages. 

©

7.

Screw the flue duct to the sides of the fixing bracket 

using two screws. 

ª

'

(

)

*

[

$

%

&

Содержание D86ER22N0B/02

Страница 1: ...en Instructions for installation and use Extractor hood...

Страница 2: ...ocation This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufact...

Страница 3: ...oming exhaust air wall boxes or by other technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest the suitab...

Страница 4: ...les replaced by one of our trained after sales technicians If the appliance is defective unplug the appliance from the mains or switch off the circuit breaker in the fuse box Contact the after sales s...

Страница 5: ...ated carbon filter The different options for operating the appliance in circulating air mode can be found in the brochure Alternatively ask your dealer The required accessories are available from spec...

Страница 6: ...switch off the circuit breaker in the fuse box Warning Risk of electric shock Do not use any high pressure cleaners or steam cleaners which can result in an electric shock Warning Risk of injury Comp...

Страница 7: ...together with utensils Place the metal mesh grease filters loosely in the dishwasher The metal mesh grease filters must not be wedged in Removing metal grease filter 1 Open the lock and fold down the...

Страница 8: ...and wattage Note When inserting halogen bulbs do not touch the glass bulb Use a clean cloth to insert the halogen bulbs 1 Carefully remove the bulb ring using a suitable tool 2 Remove the bulb and rep...

Страница 9: ...ir is carried out by trained service technicians who carry original spare parts for your appliances Accessories for circulating air mode not included in the delivery Notes Follow the installation inst...

Страница 10: ...extractor hood must correspond at least with the width of the hob For the installation observe the currently valid building regulations and the regulations of the local electricity and gas suppliers W...

Страница 11: ...ance connected to a chimney flue the electricity supply to the hood must be equipped with a suitable safety switch Warning Risk of fire Grease deposits in the grease filter may catch fire The specifie...

Страница 12: ...of the round pipes dia 150 mm ca 177 cm2 dia 120 mm ca 113 cm2 Flat ducts should not have any sharp deflections Use sealing strips for deviating pipe diameters Checking the wall The wall must be leve...

Страница 13: ...extractor hood 2 Mark positions for the screws and the contour of the attachment area 3 Drill five 8 mm diameter holes to a depth of 80 mm for the attachments and press in the wall plugs flush with t...

Страница 14: ...connector and seal Exhaust air pipe 120 mm 1 Attach the reducing connector directly to the air pipe connector 2 Attach the exhaust air pipe to the reducing connector 3 Seal both joints appropriately A...

Страница 15: ...6...

Страница 16: ...www neff international com 9001028102 9001028102 961015 Constructa Neff Vertriebs GmbH Carl Wery Stra e 34 D 81739 M nchen Register your product online...

Отзывы: