  Important safety information   

en

3

(

Important safety 

information

Important

 safety i

nformatio

n

:

Warning

Danger of suffocation!

Packaging material is dangerous to children. 

Never allow children to play with packaging 

material.

:

Warning

Danger of death!

Risk of poisoning from flue gases that are 

drawn back in.

Always ensure adequate fresh air in the room 

if the appliance is being operated in exhaust 

air mode at the same time as room air-

dependent heat-producing appliance is being 

operated.

Room air-dependent heat-producing 

appliances (e.g. gas, oil, wood or coal-

operated heaters, continuous flow heaters or 

water heaters) obtain combustion air from the 

room in which they are installed and discharge 

the exhaust gases into the open air through an 

exhaust gas system (e.g. a chimney).

In combination with an activated vapour 

extractor hood, room air is extracted from the 

kitchen and neighbouring rooms - a partial 

vacuum is produced if not enough fresh air is 

supplied. Toxic gases from the chimney or the 

extraction shaft are sucked back into the living 

space.

Adequate incoming air must therefore 

always be ensured.

An incoming/exhaust air wall box alone will 

not ensure compliance with the limit.

Safe operation is possible only when the 

partial vacuum in the place where the heat-

producing appliance is installed does not 

exceed 4 Pa (0.04 mbar). This can be 

achieved when the air needed for combustion 

is able to enter through openings that cannot 

be sealed, for example in doors, windows, 

incoming/exhaust air wall boxes or by other 

technical means.

In any case, consult your responsible Master 

Chimney Sweep. He is able to assess the 

house's entire ventilation setup and will 

suggest the suitable ventilation measures to 

you.

Unrestricted operation is possible if the vapour 

extractor hood is operated exclusively in the 

circulating-air mode.

:

Warning

Risk of fire!

Grease deposits in the grease filter may 

catch fire.

Clean the grease filter at least every 

2 months. 

Never operate the appliance without the 

grease filter.

Risk of fire!

Grease deposits in the grease filter may 

catch fire. Never work with naked flames 

close to the appliance (e.g. flambéing). Do 

not install the appliance near a heat-

producing appliance for solid fuel (e.g. 

wood or coal) unless a closed, non-

removable cover is available. There must 

be no flying sparks.

Risk of fire!

Hot oil and fat can ignite very quickly. Never 

leave hot fat or oil unattended. Never use 

water to put out burning oil or fat. Switch off 

the hotplate. Extinguish flames carefully 

using a lid, fire blanket or something similar. 

Risk of fire!

When gas burners are in operation without 

any cookware placed on them, they can 

build up a lot of heat. A ventilation 

appliance installed above the cooker may 

become damaged or catch fire. Only 

operate the gas burners with cookware on 

them.

Risk of fire!

Operating several gas burners at the same 

time gives rise to a great deal of heat. A 

ventilation appliance installed above the 

cooker may become damaged or catch fire. 

Never operate two gas burners 

simultaneously on the highest flame for 

longer than 15 minutes. One large burner of 

more than 5 kW (wok) is equivalent to the 

power of two gas burners.

Содержание D76SH52N0B/02

Страница 1: ... en Instructions for installation and use Extractor hood ...

Страница 2: ... appliance works perfectly at its installation location This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufacturer is not liable for damage which is caused by improper use or incorrect operation This appliance may be used by children over the age of 8 years old ...

Страница 3: ...coming exhaust air wall boxes or by other technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest the suitable ventilation measures to you Unrestricted operation is possible if the vapour extractor hood is operated exclusively in the circulating air mode Warning Risk of fire Grease deposits in the grease f...

Страница 4: ...bles replaced by one of our trained after sales technicians If the appliance is defective unplug the appliance from the mains or switch off the circuit breaker in the fuse box Contact the after sales service Risk of electric shock Do not use any high pressure cleaners or steam cleaners which can result in an electric shock Causes of damage Caution Risk of damage due to corrosion Always switch on t...

Страница 5: ...itch it off again several minutes after you have finished cooking This is the most effective way of removing the kitchen fumes Control panel model 1 Control panel Setting the fan Switching on the appliance Press the button The fan starts at setting ƒ Press the or button to change the fan strength Switching off Press the button Intensive setting You can use the intensive setting if there is a large...

Страница 6: ... at setting ƒ Press the or button to change the fan strength Switching off Press the button Intensive setting You can use the intensive setting if there is a large build up of odours and fumes vapours Press the button ƒ appears in the display Press the button to switch back to the intensive setting After approx six minutes the electronics automatically reduce the fan to a lower setting If you want...

Страница 7: ...e cleaners or steam cleaners which can result in an electric shock Warning Risk of injury Components inside the appliance may have sharp edges Wear protective gloves Cleaning agents Observe the information in the table to ensure that the different surfaces are not damaged by using the wrong type of cleaning agent Do not use harsh or abrasive cleaning agents cleaning agents with a high concentratio...

Страница 8: ...sher The metal mesh grease filters must not be wedged in By hand Note You can use a special grease solvent for stubborn dirt It can be ordered via the Online Shop Soak the metal mesh grease filters in a hot soapy solution Clean the filters with a brush and then rinse them thoroughly Leave the metal mesh grease filters to drain Removing metal grease filter 1 Open the lock and fold down the metal gr...

Страница 9: ...hen inserting halogen bulbs do not touch the glass tube Use a clean cloth to insert the halogen bulbs 1 Carefully remove the bulb ring using a suitable tool 2 Pull out the bulb and replace it with a bulb of the same type 3 Insert the bulb cover 4 Insert the mains plug or switch on the fuse again LED lights Defective LED lights may be replaced by the manufacturer their customer service or a qualifi...

Страница 10: ...air is carried out by trained service technicians who carry original spare parts for your appliances Accessories for circulating air mode not included in the delivery Notes Follow the installation instructions supplied with the accessories For appliances with an additional internal filter only the CleanAir recirculation module can be used Basic equipment Starter set for circulating air mode narrow...

Страница 11: ...ructions The installer is responsible for ensuring that the appliance works perfectly at its installation location The width of the extractor hood must correspond at least with the width of the hob For the installation observe the currently valid building regulations and the regulations of the local electricity and gas suppliers When conveying the exhaust air official and legal regulations e g sta...

Страница 12: ... responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest the suitable ventilation measures to you Unrestricted operation is possible if the vapour extractor hood is operated exclusively in the circulating air mode Warning Danger of death Risk of poisoning from flue gases that are drawn back in If installing a ventilation system in a room with a h...

Страница 13: ...erformance is not achieved and fan noise is increased The pipes or hoses for laying the exhaust air line must consist of non combustible material Round pipes An inner diameter of 150 mm but at least 120 mm is recommended Flat ducts The inner cross section must correspond to the diameter of the round pipes dia 150 mm ca 177 cm2 dia 120 mm ca 113 cm2 Flat ducts should not have any sharp deflections ...

Страница 14: ... extractor hood 2 Mark positions for the screws and the contour of the attachment area 3 Drill five 8 mm diameter holes to a depth of 80 mm for the attachments and press in the wall plugs flush with the wall Installation 1 Screw on the fixing bracket for the flue duct 2 Screw on brackets for the extractor hood hand tight Do not firmly tighten the screws 3 Screw in the threaded bolt leaving it prot...

Страница 15: ...connector and seal Exhaust air pipe Ø 120 mm 1 Attach the reducing connector directly to the air pipe connector 2 Attach the exhaust air pipe to the reducing connector 3 Seal both joints appropriately Attaching the flue duct Warning Risk of injury From sharp edges during installation Always wear protective gloves while installing the appliance 1 Separate the flue ducts To do this remove the adhesi...

Страница 16: ...www neff international com 9001028149 9001028149 941103 Constructa Neff Vertriebs GmbH Carl Wery Straße 34 D 81739 München Register your product online ...