background image

11

Removing and installing the grease filters

Activated carbon filters bind the odours in

circulating-air mode.

Installing and removing the activated
carbon filters

1.

Remove the grease filters (see Removing
and installing the metal-mesh grease filters).

2.

Insert the activated carbon filter.

3.

Lock the catch.

4.

Reinsert the grease filters (see Removing
and installing the metal-mesh grease filters).

Changing the activated carbon filter

Under normal operation (daily 1 to 2 hours)

the activated carbon filters must be replaced
approximately 2x year.

The activated carbon filter is available from

specialist outlets, customer service or the
Online Shop (see Optional accessories). Use
original filters only.

Activated carbon filters do not contain any

pollutants. They can be disposed of in the
household refuse.

Before removing and installing the grease

filters, always follow the instructions and
warnings in the chapter entitled ”Safety
instructions”!

Removing and installing the metal-mesh
grease filters

1.

Open the lock and fold down the grease
filters. In doing so, hold the underside of the
grease filters with your other hand.

(for appliances with edge extraction)

2.

Clean the grease filters.

3.

Reinsert the cleaned grease filters.

Содержание D76E21N0GB

Страница 1: ...Installation instructions and how to use and look after your built in cooker hoods NEFF UK Ltd...

Страница 2: ...Abb 1 ELECTRO Fig 1 GAZ 2...

Страница 3: ...installation 7 Operating modes 8 Exhaust air mode 8 Circulating air mode 8 Operation 9 Cleaning and Care 10 Removing and installing the grease filters 11 Removing and installing the metal mesh grease...

Страница 4: ...hazardous for children Therefore keep them outside the reach of children Disposal of the old appliance Old appliances are not worthless rubbish Valuable raw materials can be reclaimed by recycling old...

Страница 5: ...stomer service or a similarly qualified person to prevent hazardous situations Only a qualified technician may install including electrical connection service or repair the extractor hood Always isola...

Страница 6: ...bs observe the appropriate national statutory regulations e g in Germany Technische Regeln Gasinstallation TRGI Observe the currently valid installation regulations and instructions of the gas applian...

Страница 7: ...food with oils or fats e g chips Overheated oils or fats can easily ignite A risk of fire can be prevented by cleaning the grease filters regularly and changing the activated carbon filter in good tim...

Страница 8: ...to the exterior by a pipe system Circulating airmode The air which is drawn in is cleaned by the grease filters and an activated carbon filter and conveyed back into the kitchen An activated carbon f...

Страница 9: ...ting 2 or 3 Switching off the fan Press button 0 Light The light can be switched on and off independently of the fan For appliances with Intensive setting The Intensive setting P generates maximum per...

Страница 10: ...ase particles from the kitchen fumes The filter mats consist of fire proof metal RISK OF FIRE As the filters become more saturated with greasy residue the flammability increases The function of the ex...

Страница 11: ...be replaced approximately 2x year The activated carbon filter is available from specialist outlets customer service or the Online Shop see Optional accessories Use original filters only Activated carb...

Страница 12: ...e chapter entitled Safety instructions The description of changing the bulbs applies to several appliance models NOTE Observe the warranty regulations in the enclosed service booklet Changing the halo...

Страница 13: ...ong rough exhaust air pipes a lot of pipe bends or pipe diameters less than 150 mm are used the air capacity will be less than optimum and there will be an increase in noise Use only pipes or hoses ma...

Страница 14: ...equired connection data can be found on the rating plate inside the appliance when the grease filters have been removed Length of the power cord approx 1 30 m This extractor hood complies with the EC...

Страница 15: ...installation location check for concealed electrical cables and other lines The wall must be level and vertical The enclosed screws and wall plugs are suitable for solid brickwork Use the appropriate...

Страница 16: ...hood 3 Drill 4x 8 mm holes for attachment of the extractor hood and 2x 8 mm holes for the fixing bracket for the flue duct and press in wall plugs flush with the wall 4 Screw on the fixing bracket for...

Страница 17: ...earing protective gloves during installation 1 Separate the flue ducts To do this remove the adhesive tape 2 Remove the protective film from both flue ducts 3 Insert one flue duct into the other NOTE...

Страница 18: ...18 Notes...

Страница 19: ...19 Notes...

Страница 20: ...20 Notes...

Страница 21: ...21 Notes...

Страница 22: ...22 Notes...

Страница 23: ...23 Accessories Z5131X5 Z5132X5 Z5133X5 669419 236 669659 321 669648 281...

Страница 24: ...9000 414 350 Printed in Germany 0109 Es NEFF UK Ltd Grand Union House Old Wolverton Road Old Wolverton Milton Keynes MK12 5PT Tel 01908 328300 Fax 01908 328399...

Отзывы: