Содержание D65IHM1S2B

Страница 1: ...en Instructions for installation and use Extractor hood...

Страница 2: ...on This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufacturer...

Страница 3: ...dows incoming exhaust air wall boxes or by other technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest th...

Страница 4: ...the after sales service Risk of electric shock Incorrect repairs are dangerous Repairs may only be carried out and damaged power cables replaced by one of our trained after sales technicians If the a...

Страница 5: ...des OperatingmodesExhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms which contain he...

Страница 6: ...ol Intensive setting You can use the intensive setting if there is a large build up of odours and fumes vapours Switching on Touch the symbol Note After approx 6 minutes the extractor hood automatical...

Страница 7: ...ote Wash new sponge cloths thoroughly before use Note Follow all instructions and warnings included with the cleaning products Removing metal grease filter 1 Open the glass front slowly and fully Hold...

Страница 8: ...inse them thoroughly Leave the metal grease filters to drain on an absorbent material In the dishwasher Note Slight discolouration may occur if the metal grease filters are cleaned in the dishwasher T...

Страница 9: ...iance You can make a note of the numbers of your appliance and the telephone number of the after sales service in the space below to save time should it be required Please be aware that a visit by an...

Страница 10: ...ilter for starter set Z51AIU0X0 Z51AIA0X0 Starter set for air recirculation mode angled hood without chimney Easy change filter for starter set Z51AIT0X0 Z51AIA0X0 Starter set for air recirculation mo...

Страница 11: ...rated in air recirculation mode an optional accessory must be fitted To do this refer to the installation instructions provided The flue duct does not need to be fitted for air recirculation mode For...

Страница 12: ...n location The surfaces of the appliance are easily damaged Avoid damaging them during installation The width of the extractor hood must correspond at least with the width of the hob For the installat...

Страница 13: ...coming exhaust air wall box alone will not ensure compliance with the limit Safe operation is possible only when the partial vacuum in the place where the heat producing appliance is installed does no...

Страница 14: ...ning Danger of suffocation Packaging material is dangerous to children Never allow children to play with packaging material KGeneral information GeneralinformationChecking the wall The wall must be le...

Страница 15: ...ood should be positioned and lightly mark where the lower edge of the appliance should be on the wall Determine where the middle should be based on the hob Note We recommend fitting the extractor hood...

Страница 16: ...out a flue duct Installation Screw in the mounting supports for the extractor hood until they are hand tight use a spirit level to level the appliance and then screw the mounting supports in fully PP...

Страница 17: ...ints Attaching the flue duct If the extractor hood is to be operated in exhaust air mode a flue duct must be fitted The flue duct does not need to be fitted for air recirculation mode Warning Risk of...

Страница 18: ...6...

Страница 19: ...6...

Страница 20: ...nstructa Neff Vertriebs GmbH Carl Wery Stra e 34 D 81739 M nchen Register your product online Valid within Great Britain Imported to Great Britain by BSH Home Appliances Ltd Grand Union House Old Wolv...

Отзывы: