24

Before installation

Optimum efficiency of the extractor
hood:

Short, smooth exhaust pipe.

As few bends as possible.

Pipe diameter as large as possible 
(ideally 150 mm dia.) and wide pipe
bends.

If long, rough exhaust-air pipes,
many pipe bends or smaller pipe 
diameters are used, the air extraction
rate will no longer be at an optimum
level and there will be an increase in
noise.

Round pipes
Short exhaust air pipe:

inside diameter

min. 120 mm,

Longer exhaust air pipe:

inside diameter

min. 150 mm.

Flat ducts 

must have an

inside 

cross-section equivalent

to that of the

round pipes.

There should be no sharp bends.

l

120 mm dia. approx. 113 cm

2

l

150 mm dia. approx. 177 cm

2

If pipe diameters differ, 

insert sealing

strip.

Ensure that there is an adequate air
supply for

exhaust air mode.

Exhaust air directed backwards:

Only possible inside tall wall cupboards
depending on the size of the exhaust air
pipe.

Make a hole in the rear panel of the wall
cupboard, cutting out a notch for the
power supply cable.

Circulating-air mode

With activated carbon filter if exhaust-air
mode is not possible.

Exhaust air directed upwards:

The complete

installation set can
be obtained 

from

specialist

outlets.

The corresponding
accessory numbers
can be found at the
end of these opera-
ting instructions.

1.

Make a hole in the top of the wall cupbo-
ard, cutting out a notch for the power
supply cable.
– template 

O

I

enclosed –.

2.

If fitted, cut out the cupboard base to a
min. depth of 270 mm over the entire
width.

Note:

An installation kit is required if the width
of the cupboard is 900 mm.

Connecting a 150 mm exhaust pipe:

Attach the exhaust pipe directly to the air
connector.

Connection of 120 mm 

l

exhaust air

pipe:

Attach enclosed reducing connector to
the air outlet. 
Holes in the air outlet must be sealed.

Attach exhaust air pipe to the reducing
connector.

Содержание D4962X0

Страница 1: ...eanweisung en Operating and installation instructions fr Notice de montage et d utilisation nl Gebruiks en montageaanwijzing it Istruzioni per l uso e l installatore es Instrucciones de uso y montaje...

Страница 2: ...2 de Seite 03 15 en page 16 28 fr page 29 41 nl pagina 42 54 it pagina 55 67 es p gina 68 80 el 81 93 Abb 1 GAS ELEKTRO GAZ ELECTR KAASU ELETT GASS EL...

Страница 3: ...rresponding accessory numbers can be found at the end of these operating instructions The extractor hood fan extracts the kitchen vapours which are purified in the grease filter and activated carbon f...

Страница 4: ...tructions for Use carefully They contain important information concerning your personal safety as well as on use and care of the appliance Please retain the operating and installation instructions for...

Страница 5: ...r to stop Sliding switch remains as selected To switch on the extractor again just pull out the filter unit The extractor hood will start at the most recent fan setting Light The light can be switched...

Страница 6: ...of the extractor hood may be impaired Important Clean the metal mesh grease filters at regular intervals to prevent the risk of fire from the accumulation of heat when deep fat frying or roasting If...

Страница 7: ...ters Disposing of the old activated carbon filter Activated carbon filters do not contain any pollutants and can be disposed of with domestic refuse Filters and maintenance Activated carbon filter For...

Страница 8: ...same direction as it has been ground and polished Do not use any of the following to clean stainless steel surfaces abrasive sponges cleaning agents containing sand soda acid or chloride Aluminium an...

Страница 9: ...ill form on the underside of the extractor hood Old appliances are not worthless rubbish Valuable raw materials can be reclaimed by recycling old appliances Before disposing of your old appliance rend...

Страница 10: ...4 Pa 0 04 mbar This can be achieved if the combustion air is able to flow through non lockable openings e g in doors windows and in conjunction with an air supply air intake wall box or by other tech...

Страница 11: ...possible inside tall wall cupboards depending on the size of the exhaust air pipe Make a hole in the rear panel of the wall cupboard cutting out a notch for the power supply cable Circulating air mode...

Страница 12: ...epth 293 to 350 mm height min 435 mm If the cupboard is deeper than 293 mm the extractor hood can be moved back e g to put a spice rack in front of the extractor hood To do this place the template O I...

Страница 13: ...ove grease filter see Operating instructions 2 Lift the extractor hood into the cupboard from below until both fixing lugs have locked firmly into position Align the extractor hood in the cupboard Car...

Страница 14: ...handle moulding A handle moulding must be attached to the filter drawer This handle moulding may be a wooden strip which matches the kitchen units or a handle moulding available as an optional accesso...

Страница 15: ...or coloured red The extractor hood may be connected to a correctly installed earthed socket only Attach the earthed socket near the extractor hood in an accessible position The earthed socket should...

Страница 16: ...94 Notizen...

Страница 17: ...95 Z5144X5 434229 Aluminium Z5779A0 Metall Z5779N0 1 3 4 2 5 3x...

Страница 18: ...5750 204 891 Printed in Germany 0803 Es Postfach 10 02 50 D 80076 M nchen Fax 0 89 45 90 30 99 Internet http www neff de 1 0 12 min DTAG D4962X0 D4972X0...

Отзывы: