background image

 General information  

en

13

:

Warning

Risk of fire!

Grease deposits in the grease filter may catch 

fire. The specified safety distances must be 

observed in order to prevent an accumulation 

of heat. Observe the specifications for your 

cooking appliance. If gas and electric hobs 

are operated together, the largest specified 

distance applies.

Only one side of the appliance may be 

installed directly next to a high-sided unit or a 

wall. The distance between the appliance and 

wall or high-sided unit must be at least 50 

mm. 

:

Warning

Risk of injury!

Components inside the appliance may have 

sharp edges. Wear protective gloves.

Risk of injury!

The appliance may fall down if it has not 

been properly fastened in place. All 

fastening components must be fixed firmly 

and securely.

Risk of injury!

The appliance is heavy. To move the 

appliance, 2 people are required. Use only 

suitable tools and equipment.

:

Warning

Risk of electric shock!

Components inside the appliance may have 

sharp edges. These may damage the 

connecting cable. Do not kink or pinch the 

connecting cable during installation.

:

Warning

Risk of electric shock!

It must always be possible to disconnect the 

appliance from the electricity supply. The 

appliance must only be connected to a 

protective contact socket which has been 

correctly installed. If the plug is no longer 

accessible following installation of the 

appliance, or a fixed connection is required, 

an all-pole isolating switch must be present on 

the installation side with a contact gap of at 

least 3 mm. The fixed connection must only be 

installed by an electrician.

:

Warning

Danger of suffocation!

Packaging material is dangerous to children. 

Never allow children to play with packaging 

material.

K

General information

General i

nformatio

n

Exhaust air mode

:

Warning

Risk of death!

Risk of poisoning from flue gases that are drawn back 

in. The exhaust air must not be conveyed into a 

functioning smoke or exhaust gas flue or into a shaft 

which is used to ventilate installation rooms that contain 

heating appliances. If the exhaust air is to be conveyed 

into a non-functioning smoke or exhaust gas flue, you 

must obtain the consent of the heating engineer 

responsible.

If the exhaust air is conveyed through the outer wall, a 

telescopic wall box should be used.

Exhaust duct

Note: 

The appliance manufacturer does not provide any 

warranty for faults attributable to the pipe section.

The appliance achieves its optimum performance by 

means of a short, straight exhaust air pipe and as 

large a pipe diameter as possible.

As a result of long, rough exhaust air pipes, many 

pipe bends or pipe diameters that are smaller than 

150 mm, the optimum extraction performance is not 

achieved and fan noise is increased.

The pipes or hoses for laying the exhaust air line 

must consist of non-combustible material.

Round pipes

 

An inner diameter of 150 mm, but at least 120 mm, is 

recommended.

Flat ducts

 

The inner cross-section must correspond to the 

diameter of the round pipes.

150 mm diameter, approx. 177 cm

2

120 mm diameter, approx. 113 cm

2

Flat ducts should not have any sharp deflections.

Use sealing strips for different pipe diameters.

‘

‘

‘

‘

Содержание D46ML54N0B

Страница 1: ...en Instructions for installation and use Extractor hood...

Страница 2: ...location This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufac...

Страница 3: ...oming exhaust air wall boxes or by other technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest the suitab...

Страница 4: ...les replaced by one of our trained after sales technicians If the appliance is defective unplug the appliance from the mains or switch off the circuit breaker in the fuse box Contact the after sales s...

Страница 5: ...s Operatingmodes Exhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms which contain hea...

Страница 6: ...the AirFresh function press the button Noise reduction function The noise reduction function reduces the fan noise Switching on the appliance Press the 4 button The function is possible in all fan se...

Страница 7: ...sensor setting the fan automatically switches to another fan setting Default sensitivity setting Lowest sensitivity setting Highest sensitivity setting If the sensor control responds too quickly or t...

Страница 8: ...cleaners or steam cleaners which can result in an electric shock Warning Risk of injury Components inside the appliance may have sharp edges Wear protective gloves Cleaning agents Observe the informat...

Страница 9: ...th a brush and then rinse them thoroughly Leave the metal mesh grease filters to drain In the dishwasher Note If the metal mesh grease filters are cleaned in the dishwasher slight discolouration may o...

Страница 10: ...all countries in the enclosed customer service list To book an engineer visit and product advice Rely on the professionalism of the manufacturer You can therefore be sure that the repair is carried ou...

Страница 11: ...dual features are described which do not apply to your appliance This appliance is installed in a upper cabinet Follow the enclosed installation instructions for additional special accessories e g for...

Страница 12: ...pendent heat producing appliance is being operated Room air dependent heat producing appliances e g gas oil wood or coal operated heaters continuous flow heaters or water heaters obtain combustion air...

Страница 13: ...tallation side with a contact gap of at least 3 mm The fixed connection must only be installed by an electrician Warning Danger of suffocation Packaging material is dangerous to children Never allow c...

Страница 14: ...the units The fitted unit must be level and have sufficient load bearing capacity The max weight of the extractor hood is 18 kg Appliance dimensions and safety clearances Observe the appliance s dimen...

Страница 15: ...dle strip must be screwed into the filter pull out This handle strip can be one that is provided with the appliance or one that is available as an accessory 1 Use the screws provided to secure the han...

Страница 16: ...using with the spring 3 Carefully remove the appliance 4 Screw in the filler strip fully 5 Reinsert the springs and fastening bolts Note The mounting pieces on the left and right of the appliance must...

Страница 17: ...slot specified Connecting the pipes Note If an aluminium pipe is used smooth the area where it is to be connected before you connect it Exhaust air pipe dia 150 mm recommended size Fit the exhaust air...

Страница 18: ......

Страница 19: ......

Страница 20: ...www neff international com 9001058693 9001058693 951101 Constructa Neff Vertriebs GmbH Carl Wery Stra e 34 D 81739 M nchen Register your product online...

Отзывы: