Read these instructions carefully. Only then 

will you be able to operate your appliance 

safely and correctly. Retain the instruction 

manual and installation instructions for future 

use or for subsequent owners.
The appliance can only be used safely if it is 

correctly installed according to the safety 

instructions. The installer is responsible for 

ensuring that the appliance works perfectly at 

its installation location.
The width of the extractor hood must 

correspond at least with the width of the hob.
For the installation, observe the currently valid 

building regulations and the regulations of the 

local electricity and gas suppliers.
When conveying the exhaust air, official and 

legal regulations (e.g. state building 

regulations) must be followed.

:

Warning

Risk of death!

Risk of poisoning from flue gases that are 

drawn back in. The exhaust air must not be 

conveyed into a functioning smoke or exhaust 

gas flue or into a shaft which is used to 

ventilate installation rooms that contain 

heating appliances. If the exhaust air is to be 

conveyed into a non-functioning smoke or 

exhaust gas flue, you must obtain the consent 

of the heating engineer responsible.

:

Warning

Danger of death!

Risk of poisoning from flue gases that are 

drawn back in.

Always ensure adequate fresh air in the room 

if the appliance is being operated in exhaust 

air mode at the same time as room air-

dependent heat-producing appliance is being 

operated.

Room air-dependent heat-producing 

appliances (e.g. gas, oil, wood or coal-

operated heaters, continuous flow heaters or 

water heaters) obtain combustion air from the 

room in which they are installed and discharge 

the exhaust gases into the open air through an 

exhaust gas system (e.g. a chimney).

In combination with an activated vapour 

extractor hood, room air is extracted from the 

kitchen and neighbouring rooms - a partial 

vacuum is produced if not enough fresh air is 

supplied. Toxic gases from the chimney or the 

extraction shaft are sucked back into the living 

space.

Adequate incoming air must therefore 

always be ensured.

An incoming/exhaust air wall box alone will 

not ensure compliance with the limit.

Safe operation is possible only when the 

partial vacuum in the place where the heat-

producing appliance is installed does not 

exceed 4 Pa (0.04 mbar). This can be 

achieved when the air needed for combustion 

is able to enter through openings that cannot 

be sealed, for example in doors, windows, 

incoming/exhaust air wall boxes or by other 

technical means.

In any case, consult your responsible Master 

Chimney Sweep. He is able to assess the 

house's entire ventilation setup and will 

suggest the suitable ventilation measures to 

you.

Unrestricted operation is possible if the vapour 

extractor hood is operated exclusively in the 

circulating-air mode.

:

Warning

Danger of death!

Risk of poisoning from flue gases that are 

drawn back in. If installing a ventilation system 

in a room with a heat-producing appliance 

connected to a chimney/flue, the electricity 

supply to the hood must be equipped with a 

suitable safety switch.

Содержание D46ED52X0

Страница 1: ...en Instructions for installation and use Extractor hood...

Страница 2: ...Do not leave the appliance unattended during operation The manufacturer is not liable for damage which is caused by improper use or incorrect operation This appliance is intended for use up to a maxi...

Страница 3: ...e grease filter may catch fire Clean the grease filter at least every 2 months Never operate the appliance without the grease filter Risk of fire Grease deposits in the grease filter may catch fire Ne...

Страница 4: ...nts Risk of damage from returning condensate Install the exhaust duct in such a way that it falls away from the appliance slightly 1 slope 7Environmental protection Environmentalprotection Your new ap...

Страница 5: ...n fumes Control panel Setting the fan Switching on Pull out the filter pull out and press the button The fan starts at setting 2 Press the or button to change the fan strength Switching off Press the...

Страница 6: ...ch fire Clean the grease filter at least every 2 months Never operate the appliance without the grease filter Notes Do not use any aggressive acidic or alkaline cleaning agents When cleaning the metal...

Страница 7: ...ift the glass plate Installing the metal mesh grease filter 1 Insert the metal mesh grease filter While doing this place the other hand under the metal mesh grease filter 2 Fold the metal mesh grease...

Страница 8: ...ate with these numbers can be found inside the appliance remove the metal mesh grease filter to gain access You can make a note of the numbers of your appliance and the telephone number of the after s...

Страница 9: ...dual features are described which do not apply to your appliance This appliance is installed in a upper cabinet Follow the enclosed installation instructions for additional special accessories e g for...

Страница 10: ...pendent heat producing appliance is being operated Room air dependent heat producing appliances e g gas oil wood or coal operated heaters continuous flow heaters or water heaters obtain combustion air...

Страница 11: ...an electrician may install the fixed connection We recommend installing a residual current circuit breaker RCCB in the appliance s power supply circuit Warning Danger of suffocation Packaging material...

Страница 12: ...sufficient load bearing capacity The max weight of the extractor hood is 18 kg Appliance dimensions and safety clearances Observe the appliance s dimensions Comply with the safety clearances If the in...

Страница 13: ...he appliance or one that is available as an accessory 1 Use the screws provided to secure the handle strip to the filter pull out 2 Connect the power cord provided to the appliance 3 Use the strain re...

Страница 14: ...the appliance 4 Screw in the filler strip fully 5 Push in the fastening bolt and turn it 90 Note The fastening pieces on the left and right of the appliance must be able to move Final fitting stage 1...

Страница 15: ...slot specified Connecting the pipes Note If an aluminium pipe is used smooth the area where it is to be connected before you connect it Exhaust air pipe dia 150 mm recommended size Fit the exhaust air...

Страница 16: ...www neff international com 9001058662 9001058662 960211 Constructa Neff Vertriebs GmbH Carl Wery Stra e 34 D 81739 M nchen Register your product online...

Отзывы: