4.2.22 FlushCy2
Menu for setting the amount of time for automatic flushing of the duct system by flushing valve 2 (SFV2).
FlushCy2 is activated by FlushCy1. ‘T’ is how long flushing valve 2 is open.
ESC
OK
FlushCy2
1/1
T
= 10:00s
Ta = 00:00s
T=10:00s: Time flush valve 2 (SFV2) is open. The default setting is 10
seconds.
Ta=00:00: The elapsed time since the flushing cycle started.
4.2.23 OTTmr
Menu for setting the overtime timer. If the unit needs to be used after the weekly timer has expired, the unit
can be turned on for a set number of hours by pressing the external standby button. When the OTTmr expires,
the machine goes back into Off mode.
If the unit is in Off mode and the weekly timer is not used, quickly pressing the external standby button (less
than 2 seconds) puts the unit into Standby mode for the time set in ‘T’, for example, two hours. See the figure
below.
If the unit is in Standby mode and the weekly timer is not used, quickly pressing the external standby button
(less than 2 seconds) puts the unit into Off mode after the time set in ‘T’, for example, two hours. See the figure
below.
If the weekly timer is being used, quickly pressing the external standby button (less than 2 seconds) keeps
the unit in Standby mode for an additional two hours after the closing time set in the weekly timer, see
tion 4.2.2 Set the weekly timer
To reset OTTmr so that the time is not extended, press the external standby button longer than 2 seconds and
then release.
ESC
OK
OTTmr
1/1
T
= 2:00h
Ta = 00:00s
T=02:00h: Extra time before the unit goes into Off mode. The default set-
ting is 2 hours.
Ta=00:00: The elapsed time since the overtime timer started.