Nedap uPASS TARGET Скачать руководство пользователя страница 1

 

 

  
 

 

uPASS TARGET  

 

  installation guide 

  2016-03-16 | v1.05 | 5481163 

 

 

 

 

Содержание uPASS TARGET

Страница 1: ...uPASS TARGET installation guide 2016 03 16 v1 05 5481163 ...

Страница 2: ..._________________________________________ 19 4 1 TOOLING______________________________________________________ 19 4 2 SWITCH SETTINGS ______________________________________________ 19 5 UHF FREQUENCIES____________________________________________________ 20 6 READER CONFIGURATION______________________________________________ 21 6 1 UHFTOOL SOFTWARE ___________________________________________ 21 6 2...

Страница 3: ... Gen 2 tag is supported by the uPASS Target and will output on the RS 422 RS 485 or Ethernet interfaces Also special formatted Nedap UHF tags are supported for output on special interfaces The following formats are supported Nedap UHF Wiegand tags These tags will contain all Wiegand information including facility code and parity bits All Wiegand formats can be supported The reader transparently se...

Страница 4: ... the EPC manufacturer the value may be factory programmed and locked ensuring that tags have a unique identity and theoretically cannot be cross copied This TID based anti cloning mechanism is not considered to be a strong protection Nedap UHF tags support a locked serialized TID and the uPASS Target reader can be configured to read the TID data field and send its data to the Access Control System...

Страница 5: ...king or changing connections power must be switched OFF To be sure of safety do not modify or add anything to the uPASS Target other than mentioned in this installation guide or indicated by Nedap N V 2 2 MOUNTING INSTRUCTIONS The uPASS Target can be mounted to any surface with the wall mounting bracket and Pole Mounting Set see appendix B for part numbers The uPASS Target can be aimed at the desi...

Страница 6: ...supplied with the uPASS Target reader When the Wall Mounting Bracket is assembled mount it to the wall or the Pole Mounting Set based on the dimension in Figure 2 The uPASS Target can be aimed with the Wall Mounting Bracket and when the bolts are tightened it will stay in place Figure 2 Wall Mounting Bracket ...

Страница 7: ...be ordered separately see appendix B The uPASS Target can be mounted to round poles with maximum diameter of 190 mm 7 48 inches and square poles with maximum diameter of 150 mm 5 90 inches using the Pole Mounting Set The Wall Mounting Bracket is mounted on the Pole Mounting Set Figure 3 Pole Mounting Set ...

Страница 8: ...ction hood if the ambient temperatures are 40 C 104 F or higher and more than 2 hours of direct sunlight on the uPASS Target housing The weather hood can be placed over an already mounted uPASS Target some bolts need to be loosened It is recommended that the connections to uPASS Target are made before mounting the weather protection hood If the weather protection hood is mounted the connectors are...

Страница 9: ...ed outside the security zone Figure 5 uPASS Target connectors Figure 6 shows a simplified schematic overview for most of the uPASS Target connections This figure shows the overview when the reader is in normal UHF not TRANSIT compatible mode determined by SW1 1 see chapter 4 3 Points A B and C control the direction of the serial interface to USB RS 422 RS 485 or one Ethernet channel the other is f...

Страница 10: ...T compatible mode there are three points A B and C that control the direction of the serial interface to USB RS 422 RS 485 or one Ethernet channel the other is fixed to the UHF processor A When the USB cable is connected the USB interface is used B The main comm interface setting see chapter 6 4 1 determines the use of Ethernet or RS 422 RS 485 C Determined by SW1 2 located near the USB port RS 42...

Страница 11: ... The DC power supply is used if its voltage is higher than 13 6V Otherwise the Power of Ethernet is used DC power supply A DC power supply can be connected to the uPASS Target via CONN 5 This DC power supply must be able to deliver 12Vdc 1 5A or 24Vdc 0 75A Figure 8 CONN 5 Pin Function 1 2 Ground 3 DC 4 Table 1 Power supply connection Power over Ethernet Power over Ethernet operates over Ethernet ...

Страница 12: ... This distance can be increased1 by adding termination resistors using twisted cables and or configuring a lower baud rate see chapter 6 3 1 The communication protocol used for the RS 422 and RS 485 can be found in the uPASS firmware guide It isn t possible to use the communication protocol in a bus only point to point communication is possible The default communication settings are 115200 Baud 8 ...

Страница 13: ...nerate a message on this interface unless the Extra output settings are used See chapter 6 4 3 The Wiegand Magstripe output format is determined by the programmed format of the tag Make sure to order the correct tag programming format if you want to use the Wiegand or Magstripe interface See UHF How To Order Guide for more information about ordering the UHF tags Refer to the uPASS firmware guide f...

Страница 14: ... and go to the IP address of the reader Fill in the username and password by default both blank Open Network and select Use the following IP configuration Fill in the required fields Click OK and Apply Settings The communication protocol used for the Ethernet is the same as for RS 422 and can be found in the firmware guide If the baud rate of the reader is changed the Ethernet setting for Channel ...

Страница 15: ...cted to the UHF processor but can be connected to the TRANSIT compatible processor see chapter 4 Figure 12 Mini USB interface with SW1 USB Driver installation Make sure your computer is connected to the internet The driver should install automatically via Windows update when the uPASS Target reader is connected to your PC via the USB cable Follow the driver installation wizard If you do not see th...

Страница 16: ...ormatted UHF tags The uPASS Target can replace the 120 kHz antenna The HF Data must be connected to the ANT connection and the Ground to GND see Figure 13 Figure 13 Replacement of 120 kHz antenna Another possibility is to leave the 120 kHz in place and connect the uPASS Target That way 120 kHz and uPASS Target both can be used see Figure 14 Figure 14 Addition to 120 kHz antenna The Nedap antenna i...

Страница 17: ...trols the UnLock UL color of the LED and input 2 controls the Not Authorized NA color of the LED The relay is by default set to automatic mode The relay is activated for every tag read and stays activated for the tag hold time see chapter 6 3 4 If the automatic mode is switched off the relay is operated by input 1 By default the inputs are at 5V level and are controlled by pulling them to ground T...

Страница 18: ...1 2 3 4 5 RDIS 6 Ground 7 Ground 8 Table 7 Reader disable connection 3 3 3 EXTERNAL ANTENNA It is possible to connect an external Nedap UHF antenna to the uPASS Target reader The external UHF antenna can be used in 3 possible configurations see chapter 6 4 6 1 Internal only This mode is used if no external antenna is connected 2 External only This mode is used if the uPASS reader cannot be mounted...

Страница 19: ...ings of the Ethernet can be changed with the web interface Open the browser and go to the readers IP address Fill in the username and password by default both blank Open Channel 1 Serial Settings Check if the Port Settings match the reader serials settings as for USB or RS 422 RS 485 Click OK and Apply Settings The only UHF tags that are read in TRANSIT compatible mode are Nedap UHF XS and Nedap U...

Страница 20: ...rder Guide Per region a specific frequency band is available This frequency band is divided into frequency channels If local radio regulations require frequency hopping FHSS then the uPASS Target automatically selects and uses the available channels Frequency channel selection If no frequency hopping is required it is still advised to use frequency hopping Frequency hopping is less sensitive for i...

Страница 21: ...communication protocol description in the firmware guide 6 1 UHFTOOL SOFTWARE Figure 19 UHFTOOL software 6 2 CONNECTING To connect to the uPASS reader click File Connect press F2 or click on the connect button This opens the connect panel where the connection settings can be configured In this panel the COM port can be selected or the IP address and port can be typed and the baud rate can be selec...

Страница 22: ...nfiguration sidebar In the sidebar the configuration categories are shown Expand or collapse the setting panels by clicking on it Figure 21 UHFTOOL sidebar 6 3 1 CHANGE BAUD RATE To change the baud rate the Setup baudrate window must be opened This is done by clicking on Option Setup baudrate Select the new baud rate and click OK ...

Страница 23: ...number Select Nedap to read only Nedap tags Nedap DUAL ID enables the uPASS to search for Nedap vehicle id tags When a vehicle id tag is found the uPASS searches for driver id tags Custom enables to specify custom select criteria and the data to be read Example 1 Read only Nedap UHF tags Figure 22 Read data example 1 Example 2 Read only NXP UCODE tags TID starts with E2006 and read 4 words 1 word ...

Страница 24: ...ible processor and the antenna modulation interface are not used Additionally this function can be used to verify or output the customer code Enable the option Allow other tag formats when the reader should also support other formatted tags such as Nedap UHF Wiegand formatted tags and others See the uPASS decode Nedap XS Application Note for more information TRANSIT compatible mode When using the ...

Страница 25: ...ting is the minimum time a tag is remembered During this time the front cover LED indicates a tag read and the relay is switched The Vehicle hold time setting is the time after a vehicle id tag has been found for which the reader will search for driver id tags This setting is only used in the Nedap DUAL ID mode see chapter 6 3 1 The random RF off time parameter can be used to enable multiple Nedap...

Страница 26: ...ed These settings will also be used in TRANSIT compatible mode Figure 26 LED automatic Remote control The LED can be controlled remotely by a connected access control system The UL and NA digital inputs see chapter 3 3 1 determine the color of the LED Figure 27 LED remote control Direct control With direct control the color can be controlled through serial connection The color and brightness are d...

Страница 27: ...ripe or Nedap antenna interface By default the Repeat using hold time interval is disabled The messages on the Wiegand or Magstripe will only be send once when a tag enters the read range If enabled the messages are repeated every hold time configured in chapter 6 3 4 while the tag is within the read range The setting has no effect on the Nedap antenna interface and may have effect on the serial i...

Страница 28: ...or tags that are not programmed by Nedap in a Wiegand Magstripe or Nedap XS format See uPASS Wiegand output Application Note for more information 6 4 4 FREQUENCY These settings show the reader s operating frequency region Select a frequency channel within the available frequency band for systems that do not require frequency hopping With Power on the reader can be enabled or disabled Figure 31 Fre...

Страница 29: ...ng the mode of antenna operation can be selected For the Internal and External antenna the output power can be configured This is the same setting as the Antenna output power from the read range see chapter 6 4 5 With Dwell time the maximum ON time of the antenna is configured The maximum ON time is the time in milliseconds that the antenna is activated during a tag identification round If configu...

Страница 30: ...the dropdown box or type an IP address and port default 10002 For a successful connection via RS 422 RS 485 a baud rate of 9600 must be supported This means the PC running the updater and the transport medium cables and converters must at least support a baud rate of 9600 The updater automatically tries a faster baud rate 115200 for a faster upload If this fails it will fall back on 9600 baud Alth...

Страница 31: ...V Active low input 0V 5V Output Wiegand Magstripe clock data Nedap EM4102 Nedap CR LF Other possible in TRANSIT compatible mode see TRANSIT firmware guides Relay 1 relay NO common NC 24VDC 2A Interfaces RS 422 RS 485 Ethernet and USB Air interface ISO18000 6C Polarization Circular Operating frequency Country Frequency Technique Power ETSI 865 7 867 5 MHz FHSS 4ch 2W ERP FCC 902 7 927 2 MHz FHSS 50...

Страница 32: ... 6 1 EN 55022 EN 61000 6 2 EN 61000 6 3 A1 Safety EN 60950 1 Emission EN 302 208 1 v1 4 1 EN 302 208 2 v1 4 1 ERC REC 70 03 FCC 47 CFR part 15 subpart C Section 15 247 Industry Canada RSS 247 Shock IEC 68 2 27 Ea 50 G 6 ms 10x3 dir Bump IEC 68 2 29 Eb 25 G 6ms 1000x3 dir Random vibration EN 50155 5 150Hz 5 G 20 sweeps x 3 dir ...

Страница 33: ...gion 1 EUR 865 868 MHz 9217363 Nedap uPASS Target Region 2 3 USA 902 928 MHz 9217371 Antennas Nedap uPASS Target Region 1 EUR 865 868 MHz 9219021 Nedap uPASS Target Region 2 3 USA 902 928 MHz 9219048 Mounting Wall Mounting Bracket 9984364 Pole Mounting Set 5626595 Weather Protection Hood 5762804 ...

Страница 34: ...etween the antenna and all persons Information to the User Part 15 105 b Note This equipment has been tested and found to comply with the limits for a class B digital devices pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequent energy an...

Страница 35: ... completeness its publication conveys no license under any patent or other right nor does the publisher assume liability for any consequence of its use specifica tions and availability of goods mentioned in it are subject to change without notice it is not to be reproduced in any way in whole or in part without the written consent of the publisher ...

Страница 36: ... Added inch measurements to dimensions drawings Added image of the Ethernet connector Corrected text that mini USB and TNC aren t supplied Added external antenna setting reference to tooling chapter Used correct name for the TRANSIT compatible processor update tool 1 02 2016 01 20 Added Russian frequencies Added FCC IC numbers Added Antenna part numbers Added Antenna images part numbers Added moun...