TRANSIT Entry Quick Reference 

 

 

2007-06-11 

Part no : ???????

This information is furnished for guidance, and with no guarantee as to its accuracy or completeness; its publication conveys no license 
under any patent or other right, nor does the publisher assume liability for any consequence of its use; specifications and availability of 
goods mentioned in it are subject to change without notice; it is not to be reproduced in any way, in whole or in part, without the written 
consent of the publisher. 

 

SAFETY PRECAUTIONS 
 

The following safety precautions should be observed during normal use, service and repair. 
 
• 

The TRANSIT Entry must be connected with safety ground. 

• 

The TRANSIT Entry may only be installed and serviced by qualified service personnel. 

• 

Disconnect the power supply before removing or installing any parts. 

• 

To be sure of safety, do not modify or add anything to the TRANSIT Entry other than mentioned 
in this installation guide or indicated by NEDAP N.V. 

 

Step 1  Mounting instructions 

 
The TRANSIT Entry can be mounted to any surface, even directly onto metal. Locate an appropriate 
position. Use the enclosed mounting drawing to drill appropriate upper two keyholes (K) to mount the 
reader. Open the service cover to secure the reader using the two lower mounting positions (L).  See 
the mounting sketch for more information. 
 
 

 

service cover 

K

200mm (7.87"

)

 

47mm (1.85")

220m

m (

8

.6

6

")

 

108mm (4.25")

35m

171m

m (

6

.7

3

")

 

(1

.38

")

 

63mm (2.48")

4.5mm (.17")

5mm

(.20")

4.5mm

(.17") 

rear view 

front view 

side view 

 

 
 

Step 2  Opening the service cover 
 

Open the screws on the bottom of the TRANSIT Entry to 
unlock the service cover. Once the service cover is unlocked, 
lift it off.  
 
Make sure the screws are completely opened (and closed 
when replacing the cover). Don’t worry about losing the 
screws, they cannot fall out. 

 

 

 

 

Figure 1: Service cover TRANSIT Entry 

 
Note:  Make sure the screws are completely opened (and closed when placing the cover back on). Don’t 
worry about losing the screws, they cannot fall out. 
 
 
 
 
 
 
 

Содержание TRANSIT Entry

Страница 1: ...Entry other than mentioned in this installation guide or indicated by NEDAP N V Step 1 Mounting instructions The TRANSIT Entry can be mounted to any surface even directly onto metal Locate an appropri...

Страница 2: ...minal connectors 1 Strip wire lead for about 9 mm 0 35 inch 2 Push the screwdriver straight down to release the spring cage Use a slotted narrow head screwdriver 3 Insert the wire lead into the wire t...

Страница 3: ...firmware manual for more details Connections WIEGAND MAGSTRIPE BARCODE OUT1 Card Loaded OUT2 Data 0 green Clock OUT3 Data 1 white Data Data GND Ground black Ground Ground GND OUT3 OUT2 K2 OUT1 GND DA...

Страница 4: ...tem The contacts are normally closed when the cover is in place Tamper switches of multiple TRANSIT Entry reader may be connected in series Connections NC Tamper switch normally closed COM Tamper swit...

Страница 5: ...4 SW1 On board RS422 interface enabled Note The on board RS232 and RS422 interfaces are both disabled when the USB connector is in use or when the TCP IP interface board is installed 6 3 Unused DED SW...

Страница 6: ...ve Abnormal situation SQ ENA Squelch enabled SQ ACT Squelch active DC HI Power supply voltage too high DC LO Power supply voltage too low DC FAIL Internal supply voltage failure T CRIT Temperature cri...

Страница 7: ...Wifi 50 2 4384 60 2 4480 51 2 4390 61 2 4486 52 2 4396 62 2 4492 53 2 4402 63 2 4498 54 2 4408 64 2 4504 55 2 4414 65 2 4510 56 2 4420 CH7 66 2 4516 57 2 4426 67 2 4522 CH9 58 2 4432 68 2 4528 59 2 44...

Отзывы: