41
NED
XCM2080SAT4
/
XCM2040SAT4
UME-0006-04
4.9
Exposure Mode and Timing Chart
The camera has three exposure modes. The overview of each mode and the timing
are as follows.
4.9.1 Free Run Exposure Mode (Programming time setting)
In free-run exposure mode, the camera generates its own internal control signal
based on two programmable parameters, exposure time and readout time.
Table 4-9-1-1 Programmable Exposure Time
Item
symbol
XCM2080SAT4
XCM2040SAT4
Programmable
exposure time
P
6.7
~
3276.7(4TAP)
13.4
~
3276.7 (2TAP)
13.4
~
6553.4(4TAP)
26.8
~
6553.4 (2TAP)
Readout time
R
6.4(2K 4TAP,1K 2TAP)
12.8(2K 2TAP)
12.8(2K 4TAP,1K 2TAP)
25.6(2K 2TAP)
Scan Rate
S
8
~
3279.3(4TAP)
14.7
~
3279.3 (2TAP)
16
~
6558.6(4TAP)
29.4
~
6558.6(2TAP)
(unit::
μs)
Figure 4-9-1-1 Free Run Exposure Mode
Note:
The timing of reading out does one scanning delay from the exposure.
Exposure
①
②
③
Readout
LVAL
R
P
S
①
②