![NED RMSL4K100CP Скачать руководство пользователя страница 46](http://html1.mh-extra.com/html/ned/rmsl4k100cp/rmsl4k100cp_user-manual_3826618046.webp)
46
NED
RMSL4K100CP
UME-0114-01
4.7 Exposure Mode and Timing Chart
The camera has three exposure modes. The overview of each mode and the
timing are as follows.
4.7.1 Free Run Exposure Mode (When external trigger permission is invalid)
The free-run exposure mode is the mode when external trigger permission is invalid
(Triggermode: off).
Set the camera camera control register with the AciliationLineRate and the
Programmable exposure time (ExposureTime), respectively. Settable line rate and
programmable exposure time are as follows.
Table 4-7-1-1 Programmable Exposure Time
symbol
Item
Time (us)
S
Scan period
[Line Rate = 1/scan]
20.0
~
2000.0
[500
~
50000Hz]
p
Programmable exposure time
3.600
~
1998.000 (*1)
R
Readout time
6.5 (*2)
(*1) S
≧
p+2us
(*2) S
≧
R+0.2us
①
②
③
④
⑤
p
scan
⑥
Figure 4-7-1-1 Free Run Exposure Mode
Exposure