7.4 Bending the line three times
①
For an integration time ratio of 10, use the following settings:
ExposureMode
:「
Multi Slope
」
MultiSlope_Level1
:
4, MultiSlope_Level2
:
8, MultiSlope_Level3
:
12
MultiSlope_Timing1
:
1, MultiSlope_Timing2
:
10, MultiSlope_Timing3
:
100
ExposureTimeDividing
:
16
ExposureTimeCounter
:
1023
The integration time becomes 1000 in the first slope, 100 in the second slope, 10 in the
third and 1 in the fourth. The reset levels become ¼, ½, ¾ of the saturation level, as the
diagram below indicates.
The minimum line period is 823.2us. The dynamic range becomes 284 times 1 (ratio of
saturation exposure amount: 28.4/0.1), i.e. 109dB (60dB + 20log284 = 109)