background image

USER MANUAL 2AMDI511IPVRDS

www.nectogroup.com

PARAMETERS CONFIGURATION

CLICK ON THE WANTED CONFIGURATION TO VIEW 2AMIN4030000N 

PROGRAMMER IMAGE

Reset

Configuration

A

B

C

D

1

2

3

4

5

6

7

8

9

10

Reset

ON ON ON ON ON ON ON ON ON ON ON ON ON ON

Dimming Curve

Configuration

A

B

C

D

1

2

3

4

5

6

7

8

9

10

Logarithmic

OFF OFF OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF

Linear

OFF OFF OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF ON

PWM

Configuration

A

B

C

D

1

2

3

4

5

6

7

8

9

10

PWM Standard

OFF OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF

PWM Inverted

OFF OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF ON

Fade

Configuration

A

B

C

D

1

2

3

4

5

6

7

8

9

10

Fade Off

OFF OFF ON ON OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF

Fade On

OFF OFF ON ON OFF OFF OFF OFF OFF OFF OFF OFF OFF ON

Current

Configuration

A

B

C

D

1

2

3

4

5

6

7

8

9

10

170 mA

OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF

182 mA

OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF ON

195 mA

OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF ON OFF

210 mA

OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF ON ON

222 mA

OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF ON OFF OFF

235 mA

OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF ON OFF ON

250 mA

OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF ON ON OFF

260 mA

OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF ON ON ON

270 mA

OFF ON OFF OFF OFF OFF OFF OFF OFF OFF ON OFF OFF OFF

290 mA

OFF ON OFF OFF OFF OFF OFF OFF OFF OFF ON OFF OFF ON

300 mA

OFF ON OFF OFF OFF OFF OFF OFF OFF OFF ON OFF ON OFF

315 mA

OFF ON OFF OFF OFF OFF OFF OFF OFF OFF ON OFF ON ON

330 mA

OFF ON OFF OFF OFF OFF OFF OFF OFF OFF ON ON OFF OFF

345 mA

OFF ON OFF OFF OFF OFF OFF OFF OFF OFF ON ON OFF ON

355 mA

OFF ON OFF OFF OFF OFF OFF OFF OFF OFF ON ON ON OFF

370 mA

OFF ON OFF OFF OFF OFF OFF OFF OFF OFF ON ON ON ON

385 mA

OFF ON OFF OFF OFF OFF OFF OFF OFF ON OFF OFF OFF OFF

395 mA

OFF ON OFF OFF OFF OFF OFF OFF OFF ON OFF OFF OFF ON

410 mA

OFF ON OFF OFF OFF OFF OFF OFF OFF ON OFF OFF ON OFF

425 mA

OFF ON OFF OFF OFF OFF OFF OFF OFF ON OFF OFF ON ON

438 mA

OFF ON OFF OFF OFF OFF OFF OFF OFF ON OFF ON OFF OFF

450 mA

OFF ON OFF OFF OFF OFF OFF OFF OFF ON OFF ON OFF ON

465 mA

OFF ON OFF OFF OFF OFF OFF OFF OFF ON OFF ON ON OFF

480 mA

OFF ON OFF OFF OFF OFF OFF OFF OFF ON OFF ON ON ON

490 mA

OFF ON OFF OFF OFF OFF OFF OFF OFF ON ON OFF OFF OFF

500 mA

OFF ON OFF OFF OFF OFF OFF OFF OFF ON ON OFF OFF ON

pag|10

Содержание 2AMDI511IPVRDBS

Страница 1: ...MANUAL 2AMDI511IPVRDS SUBJECT INDEX DESCRIPTION TECHNICAL SPECIFICATION DEVICE POWER SUPPLY AND CONNECTION TO THE LED MODULE OPERATION MODES LINEAR POTENTIOMETER MODE 100KOHM MODE 0 10V 1 10V PASSIVE...

Страница 2: ...s 40x100x24 45 mm Reverse polarity protection Open circuit protection Surge voltage protection Over temperature protection Short circuit protection PULSANTE N O ISOLATO DIMMER MONOCANALE MULTIPROTOCOL...

Страница 3: ...MAX OUTPUT CURRENT n OUTPUT CHANNELS MAX OUTPUT POWER CONTROL INPUTS CASE DIM 2AMDI511IPVRDS 8 53V DC DA 170mA A 1050mA 1 54 6W A 52V DC INSULATED PUSH BUTTON X1 DALI X1 LINEAR POTENTIOMETER 100K X1...

Страница 4: ...G 1 through the DC IN and terminals In case the power supply polarity is inverted no damage will be caused to the device The LED LED PWR positioned on the circuit board indicates the presence of power...

Страница 5: ...ce value of less than 5 Kohm is interpreted as load off The maximum brightness value is reached by exceeding the value of 95 Kohm In case the potentiometer is disconnected the dimmer sets the output t...

Страница 6: ...fault the dimming curve follows a logarithmic trend proportional to the control voltage A voltage value of less than 1V is interpreted as load off In case the 0 10V 1 10V signal is disconnected the di...

Страница 7: ...n N O No polarization is needed for the input signal The maximum current absorbed by the PUSH interface is about 2mA The dimmer saves the output position in order to restore the set level in case of p...

Страница 8: ...the POWER ON LEVEL mode set through DALI bus The maximum current absorbed by the DALI bus is about 2mA Below you can find the implemented standard commands DIRECT ARC POWER OFF UP DOWN STEP UP STEP DO...

Страница 9: ...NUMBER QUERY DEVICE TYPE QUERY PHISICAL MINIMUM LEVEL QUERY POWER FAILURE QUERY CONTENT DTR1 QUERY CONTENT DTR2 QUERY ACTUAL LEVEL QUERY MAX LEVEL QUERY MIN LEVEL QUERY POWER ON LEVEL QUERY SYSTEM FA...

Страница 10: ...OFF OFF OFF OFF OFF OFF OFF ON OFF OFF 235 mA OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF ON OFF ON 250 mA OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF ON ON OFF 260 mA OFF ON OFF OFF OFF OFF OFF OFF OF...

Страница 11: ...OFF ON OFF 748 mA OFF ON OFF OFF OFF OFF OFF OFF ON OFF ON OFF ON ON 761 mA OFF ON OFF OFF OFF OFF OFF OFF ON OFF ON ON OFF OFF 775 mA OFF ON OFF OFF OFF OFF OFF OFF ON OFF ON ON OFF ON 788 mA OFF ON...

Отзывы: