Nectar Sun PVHC-2.01 Скачать руководство пользователя страница 9

 

 

PHOTOVOLTAIC HEAT CONTROLER PVHC – 2.01 

 

CONTROL MANUALLY (NOT CONFIGURED MENU) 

 
Note:  

 

To navigate and go to next screen. 

 

To navigate and go to previous screen. 

 

 

To select or confirm press. 

 
Main screen in various operation modes: 

Display: 

Menu item 

Text 

Explication 

Idle 

 

 

Main display with current water 
temperature 

Active 
status 

 

Auto/Away/No 
grid/Boost 

Shows heating mode status. 

Grid/Sun/Idle 

Grid -  shows power from grid, if uses; 
Sun - displays power from pv, if uses; 
Idle 

 shows nothing. 

Active 
totals 

 

Today XX kWh 
Total XXX kWh 

Today - energy count during the day. 
TOTAL 

 total energy count from start-

up. In kWh, MWh. 

Mode 

 

 

Press to choose the mode  

 

Auto 

 

Auto mode keeps water temperature 
according to day/night temperature 
settings (pls. See settings).  
Uses grid power, if PV power is not 
enough or not available. 

 

Away 

 

Away  mode keeps water temperature 
between 10-

45°C

 

 

No grid 

 

No grid mode uses only PV for water 
heating. When this mode is selected, the 
maximum temperature could reach 75 

°C.

 

Connects to grid, if water temperature is 

< 5°C.

  

 

Boost 

 

Boosts up water temperature to 66°C.  

Connects to grid. 

Settings 

 

Settings 

Select to open settings menu 

 

Day temp. 

Day temp. 

Select the minimum temperature you 
want to heat water in day time. 
Heating from grid is turned on below this 
temperature. 

 

Night 
temp. 

Night temp. 

Select the minimum temperature you 
want to heat water at night time. 
Heating from grid is turned on below this 
temperature. 

 

Max temp. 

Max temp. 

We recommend Set maximum water 
temperature, then heating from sun 
panels. 

Содержание Sun PVHC-2.01

Страница 1: ...PHOTOVOLTAIC HEAT CONTROLER PVHC 2 01 USER MANUAL ...

Страница 2: ... HEAT CONTROLER PVHC 2 01 CONTENT CONTROL ELEMENTS AND CONNECTIONS 3 HOW IT WORKS 4 INSTALLATION PROCEDURE SWITCHING ON THE DEVICE 5 CONNECTION DIAGRAM 6 USER MENU 7 SPECIFICATIONS 11 EU Declaration of Conformity 12 ...

Страница 3: ...s 1 OLED text display 2 Touch sensitive control buttons 3 Photovoltaic modules connection POSITIVE 4 Photovoltaic modules connection NEGATIVE 5 Device connection cable to the water heating element 6 Device connection cable to the main power grid 7 Device connection cable to the temperature sensor 1 2 3 4 7 6 5 ...

Страница 4: ...d snow loads Avoid any shadow areas especially between southeast and southwest Even partialshading will lead to a significant performance reduction Note please check any national regulations for specific countries Durability and Security stands out due to exceptional Nectar Sun functionality The MPPT system inside the controller is always balancing the highest solar power depending on the solar ra...

Страница 5: ...6 Compatibility with hot water tanks please see Specifications Recommended heating element Recommended to have overpressure valve 7 Nectar Sun device must be installed as close to the boiler as possible The installation place must not hinder natural ventilation of the device and be convenient to control it For precise readings we recommend to install temperature sensor on the top of the tank 8 Nec...

Страница 6: ...ble install or perform other connection works when NectarSun device is not completely OFF CAUTION If connection polarity is reversed damage to the device is unavoidable System protection by Switch relays overvoltage and other devices Temperature sensor Power grid Water heating element PV modules ...

Страница 7: ...wing To control and set up please choose if you want to connect the device with internet via wifi and control it with Nectar Sun app For further instructions please see How to connect wifi and control via app if you want to control the device manually For further instructions please see How to control manually Note 30 min after switching on the device your Nectar Sun is ready to be connected to wi...

Страница 8: ...un displays power from pv if uses Idle shows nothing Active totals Today XX kWh Total XXX kWh Today energy from PV count during the day kWh TOTAL total energy count from PV from start up kWh MWh Settings Settings Select to open settings menu Language Language Set display language Back Back Go back to main screen Reset Reset Reset all settings day night time day night temperature time language mode...

Страница 9: ... keeps water temperature according to day night temperature settings pls See settings Uses grid power if PV power is not enough or not available Away Away mode keeps water temperature between 10 45 C No grid No grid mode uses only PV for water heating When this mode is selected the maximum temperature could reach 75 C Connects to grid if water temperature is 5 C Boost Boosts up water temperature t...

Страница 10: ...tarts Night starts Set the end of your day e g 10 30 p m Time Time Set current time Language Language Set display language Pair with wifi Pair with wifi Connect to wifi Back Back Go back to main screen Reset Reset Reset all settings day night time day night temperature time language mode To start your Nectar Sun you need to set a time 30 min after Reset you can pair the device with wifi ...

Страница 11: ...0 V Load heater 16 53 Ω OUTPUT RECOMMENDED HEATING ELEMENT 1 kW 4x250W photovoltaic panels 3 3 5 kW heat element 1 5kW 6x250W photovoltaic panels 2 2 5 kW heat element Max efficiency 99 GENERAL DATA Cooling natural convection Operating temperature range 10 C 30 C Max store humidity 75 non condensing DC connection MC4 Temperature sensor digital WLAN IEEE 802 11b g n client Degree of protection IP20...

Страница 12: ...bility Directive and Directive 2006 95 EC Low Voltage Directive The unit is compliant with the following standards 2006 95 EC Directive relating to electrical equipment designed for use within specific voltage limits 2004 108 EC Directive relating to electromagnetic compatibility Safety of the unit IEC 60950 1 2005 mod IEC 60950 1 2005 A1 2009 mod Electromagnetic disturbances EN 55011 2009 EN 5501...

Страница 13: ...gible Nectar Sun reserves the right to refuse the warranty service This warranty does not cover demage resulting from Normal wear and tear of the equipment Defects and damages due to the equipment being used other than in a normal and customary manner Any unauthorised disassembly repair alteration or modifications being carried out Misuse abuse negligence or accident howsoever caused Defects and d...

Страница 14: ...AC socket remove cover and check main power grid fuse that is shown in the internal connections diagram page 5 Check main power grid wires connection is connected properly Device turns on but sun mode doesn t work Disconnect device from AC socket unplug PV wires remove cover and check PV fuse that is show in the internal connections diagram page 5 Also check if heater wires are connected properly ...

Отзывы: