CCIS BASIC PROGRAMMING

Sample Data Programming for Open Numbering System

CIC=1

CIC=2

TRK000

TRK001

TRK002

CIC=2

RT11

31xx

CIC=1

RT10

32xx

TRK003

TRK004

TRK005

CIC=2

RT13

CIC=1

RT12

21xx

CIC=1

CIC=2

34xx

35xx

OFFICE C

PC: 00020

OFFICE NO.: 825

CCT1

CCT0

OFFICE A

PC: 00001

OFFICE NO.: 820

OFFICE B

PC: 00010

OFFICE NO.: 822

CONDITIONS:

 Open Numbering (4-digit Station No.)

 Centralized Billing: Not provided

 Trunk Blade No. of CCT on OFFICE A:

EXAMPLE

CCT0: 000

CCT1: 001

CCH00

CCH01

Содержание Univerge SV9300

Страница 1: ...Networking Manual NWA 088654 001 ISSUE 1 0 ...

Страница 2: ...oration has prepared this document for use by its employ ees and customers The information contained herein is the property of NEC Corporation and shall not be reproduced without prior written approval from NEC Corporation Dterm is a registered trademark of NEC Corporation PCPro is a trademark of NEC Corporation Copyright 2014 NEC Corporation ...

Страница 3: ... CCIS 1 7 TIME SLOT ASSIGNMENT CONDITION 1 8 Time Slot Allocation for CCT Blade 1 8 Number of Time Slots Required for CCT Blade 1 9 CCT SPECIFICATIONS 1 10 Transmission Characteristics 1 10 Frame Configuration of 24CCT 1 11 Frame Configuration of 30CCT 1 15 MODEM Specifications 1 16 SERVICES 1 17 NETWORK STRUCTURE CONSIDERATIONS 1 20 Determining System Configuration 1 20 Determining Number of No 7...

Страница 4: ...ALL CALLS CCIS MULTIPLE CALL FORWARDING ALL CALLS CCIS 1 85 CALL FORWARDING BUSY LINE CCIS MULTIPLE CALL FORWARDING BUSY LINE CCIS 1 92 CALL FORWARDING NO ANSWER CCIS MULTIPLE CALL FORWARDING NO ANSWER CCIS 1 99 CALL FORWARDING INTERCEPT CCIS 1 106 CALL FORWARDING OVERRIDE CCIS 1 108 CALL TRANSFER ALL CALLS CCIS 1 109 CALL TRANSFER ATTENDANT CCIS 1 111 CALLING NAME DISPLAY CCIS 1 113 CALLING NUMBE...

Страница 5: ... CCIS 1 206 OUTGOING TRUNK QUEUING CCIS 1 207 PAGING ACCESS CCIS 1 209 RESTRICTION FROM OUTGOING CALLS CCIS 1 222 SINGLE DIGIT STATION CALLING CCIS 1 223 STATION TO STATION CALLING CCIS 1 225 TOLL RESTRICTION 3 6 DIGITS CCIS 1 227 TRUNK ANSWER FROM ANY STATION CCIS 1 232 TRUNK TO TRUNK RESTRICTION CCIS 1 243 UNIFORM NUMBERING PLAN CCIS 1 251 VOICE CALL CCIS 1 253 VOICE MAIL INTEGRATION CCIS 1 254 ...

Страница 6: ...SYSTEM SETUP 3 21 PROGRAMMING PROCEDURE 3 23 SETTING A LAW µ LAW FOR REMOTE UNIT OVER IP 3 26 REMOTE UNIT OVER IP VoIPDB DATA ASSIGNMENT 3 27 REMOTE UNIT OVER IP VLAN DATA ASSIGNMENT 3 29 SURVIVAL MODE ASSIGNMENT 3 30 SETTING SYSTEM DATA COPY 3 31 REMOTE UNIT OVER IP LINK DOWN NOTICE ASSIGNMENT 3 32 TIME ZONE DAYLIGHT SAVING TIME DATA ASSIGNMENT 3 33 USER MOBILITY ASSIGNMENT 3 35 ISDN ALTERNATIVE ...

Страница 7: ...01 Rev 1 0 94ch0001 fm PURPOSE INTRODUCTION PURPOSE This manual explains the programming procedure for providing Common Channel Inter Office Signaling CCIS system Q SIG system and Remote UNIT over IP system to the UNIVERGE SV9300 ...

Страница 8: ...ition system specifications available services with No 7 CCIS network structure consider ations programming procedure and inter office test procedure for CCIS system CHAPTER 2 Q SIG FEATURES This chapter explains the system outline system configuration system conditions and programming procedure for Q SIG system CHAPTER 3 REMOTE UNIT OVER IP FEATURES This chapter explains the system outline system...

Страница 9: ...aw a clear line between the PBX systems they are designated as follows SV9300 UNIVERGE SV9300 SV8300 UNIVERGE SV8300 SV9500 UNIVERGE SV9500 2400 IPX NEAX 2400 IPX Internet Protocol eXchange Attendant Console Name Attendant Console is usually designated as Attendant Console When the console type is limited by a service it is designated as follows DESKCON Desk Console SN716 DESKCON ...

Страница 10: ...lly used together with a smart device The operation and the condition depend on the specifications of application on smart device COMMON TERMS TERMINAL NAMES Multiline Terminal Digital Multiline Terminal Dterm Dterm85 Series i DT400 Series DT410 DT430 DT300 Series DT310 DT330 IP Station IP Multiline Terminal IP Enabled Digital Multiline Terminal Dterm 85 Series i IP Adapter Type Dterm IP INASET Dt...

Страница 11: ...unctions and data required for programming the system Programming Manual Contains procedure for programming each business hotel ISDN and OAI feature System Data Programming Manual Contains the Customer Specifications Sheets and the System Data Programming Sheets System Maintenance Manual Contains the system maintenance services and the recommended troubleshooting procedure System Hardware Manual C...

Страница 12: ...lows 1 1st data 2 2nd data Default With the system data clear command CM00 CM01 the data with this marking is automatically set for each command A reset of the CPU blade is required after data setting Press RESET switch on the CPU blade Command with this marking can be used only under Off Line mode of the CPU blade To set Off Line mode 1 Set SENSE switch on the CPU blade to E or F 2 Press RESET sw...

Страница 13: ...et of CPU blade Changing the CPU blade to Off Line Mode Changing the CPU blade to On Line Mode after system data setting under Off Line Mode In addition the VRS data backup is also required when any data is recorded or changed in the VRS You can execute the system data backup by the following two ways Executing the system data backup once a day at the time set by CM43 Y 5 00 If no data is set the ...

Страница 14: ...8 NWA 088654 001 Rev 1 0 94ch0001 fm THIS PAGE LEFT BLANK INTENTIONALLY ...

Страница 15: ...g Manual Chapter 1 CCIS FEATURES This chapter explains the system outline time slot assignment con dition system specifications available services with No 7 CCIS network structure considerations programming procedure and in ter office test procedure for CCIS system ...

Страница 16: ...ital network a Phase Locked Oscillator PLO for digital network synchronization The system can provide a variety of inter office services such as Centralized Billing To add the Centralized Billing function Built in SMDR of CPU blade is required This figure shows the system outline of No 7 CCIS System Outline of No 7 CCIS SV9300 SV9300 2400 IPX 24 30 CH 24 30 CHANNEL PCM DIGITAL LINE CLOCK SIGNAL CP...

Страница 17: ...lock routes are available one is the route 0 from the source office and the other is a standby route 1 from a sub source office When no clock signals come from either the route 0 or route 1 due to a trans mission line failure the PLO keeps generating the clock signals at the frequency of the last source clock The PLO can receive different frequency of source clocks from the route 0 and route 1 Thi...

Страница 18: ...CCIS The PBX can provide No 7 CCIS via digital network This figure shows the system configuration of No 7 CCIS provided via digital network No 7 CCIS with CCT TDSW SV9300 2400 IPX 24 30 CHANNEL PCM DIGITAL LINE TDSW SV9300 CCT CCIS Trunk PLO Phase Locked Oscillator CPU PLO CPU CCT CCT ...

Страница 19: ...er local offices to the center office SMDR is required for each office SMDR can be accom modated in the Center Office through LAN connection RS 232C connection The following figure shows the system outline of the Centralized Billing System Outline of Centralized Billing RS 232C connection System Outline of Centralized Billing LAN connection Local Office B TDSW Local Office C CPU TDSW CCT Billing I...

Страница 20: ...tored NOTE 1 If the buffer memory on the CPU blade overflows the oldest billing data is discarded and replaced by the newest one NOTE 2 When changing the number of storing records by CM04 Y 01 12 be sure to execute the SRAM memory clear by CM00 02 11 NOTE 3 For details of the programming refer to Station Message Detail Recording SMDR of Programming Manual If the billing information is not sent to ...

Страница 21: ...onditions are the same as Conditions for Local Office Inter Office Digital Data Transmission through No 7 CCIS The PBX can provide Inter Office Digital Data Transmission through No 7 CCIS When the PBX is an end office in the Inter Office Digital Data Transmission through No 7 CCIS the digital signal is transmitted directly A maximum of 64 Kbps digital data transmission is available for the direct ...

Страница 22: ...onsecutive channels the system also allocates time slots to channels not assigned For example as shown below when Channel 1 through Channel 10 have been assigned by system data programming except Channel 5 the system allocates a total of 10 time slots for all ten channels Therefore to avoid allocation of unnecessary time slots it is recommended that consecutive channels be assigned on each CCT bla...

Страница 23: ...xed path between the CCT 2 When the system is serving as a High Hierarchy Office within the network 1 time slot is allocated to the distant Main Office and distant Local Office for the common signaling channel This table shows the number of time slots for the required blade for No 7 CCIS Number of Time Slots Required per CCT Blade for No 7 CCIS BLADE NUMBER OF TIME SLOTS PER BLADE REMARKS GCD CCTA...

Страница 24: ...Pulse Amplitude Base to Peak 3 volts 0 6 volts 2 37 volts nominal Coaxial Cable 3 volts nominal Twisted Pair Cable Pulse Width 324 ns 30 ns 244 ns nominal 2 Input Line Rate 1 544 Mbps 200 bps 130 ppm 2 048 Mbps 50 ppm Pulse Amplitude Base to Peak 1 5 volts 3 volts 1 5 volts 2 7 volts Coaxial Cable 1 5 volts 3 3 volts Twisted Pair Cable Frame Synchronization Pattern 100011011100 Input Jitter ITU T ...

Страница 25: ...d 24 Multi Frame ESF 1 12 Multi Frame D4 The frame has 12 Multi Frames and each Multi Frame has a 24 channel PCM signal 8 bits channel and an S bit Super Frame Bit This figure shows the frame configuration and the table on next page shows frame bit assignment Frame Configuration of 24CCT 12 Multi Frame S CH1 CH2 CH3 CH24 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 FRAME 1 FRAME...

Страница 26: ...01 fm CCT SPECIFICATIONS 12 Multi Frame Bit Assignment The S bit is the first bit in each frame Frames are repeated in the order shown above FRAME No S BIT TERMINAL SYNCHRONIZATION FT SIGNAL SYNCHRONIZATION FS 1 1 2 0 3 0 4 0 5 1 6 1 7 0 8 1 9 1 10 1 11 0 12 0 ...

Страница 27: ...h Multi Frame has a 24 Channel PCM signal 8 bits channel and an S bit Super Frame Bit This figure shows the frame configuration and the table on next page shows frame bit assignment Frame Configuration of 24CCT 24 Multi Frame S CH1 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 CH2 1 2 3 4 5 6 7 8 CH3 1 2 3 4 5 6 7 8 CH24 FRAME 1 FRAME 2 FRAME 3 FRAME 24 125 µs S Superframe Bit ...

Страница 28: ... first bit in each frame Frames are repeated in the order shown above m in the 4 Kbps Data Link column means that the frame is usually assigned to 1 FRAME No S BIT FRAME SYNCHRONI ZATION 4 Kbps DATA LINK CRC 1 m 2 CB1 3 m 4 0 5 m 6 CB2 7 m 8 0 9 m 10 CB3 11 m 12 1 13 m 14 CB4 15 m 16 0 17 m 18 CB5 19 m 20 1 21 m 22 CB6 23 m 24 1 ...

Страница 29: ...hod of ITU T Specification the frame configuration consists of 16 Multi Frame each Multi Frame having 32 time slots This figure shows the frame configuration and the table on next page shows the details of time slot assign ment Frame Configuration of 30CCT TS0 TS1 TS15 TS16 TS17 TS30 TS31 TS2 FRAME 0 FRAME 15 FRAME 2 FRAME 3 FRAME 14 FRAME 1 125 µs ...

Страница 30: ...00 bps Transmission Mode Full Duplex Line 2 4 wire Common Signaling Data Link via MODEM Connection Type Leased Interface Condition ITU T V24 and V28 TIME SLOT No EVEN No FRAME ODD No FRAME TS0 Frame Alignment Signal FAS TS1 TS15 Voice Channel CH1 CH15 TS16 No 7 CCIS To be used as a Common Signaling Data Channel TS17 TS31 Voice Channel CH17 CH31 b0 x 1 1 0 1 1 0 0 b 6 5 4 3 2 1 7 FAS CRC BIT b0 x 1...

Страница 31: ...All Calls CCIS Call Forwarding Busy Line CCIS Call Forwarding No Answer CCIS Call Forwarding Intercept CCIS Call Forwarding Override CCIS Call Processing Indication CCIS Call Transfer All Calls CCIS Call Transfer Attendant CCIS Called Station Status Display CCIS Calling Name Display CCIS Calling Number Display CCIS CCIS Networking via IP NOTE 5 Centralized Billing CCIS Centralized Day Night Mode C...

Страница 32: ...xible Numbering of Stations CCIS Hands Free Answerback CCIS Hot Line CCIS House Phone CCIS Incoming Call Identification CCIS Individual Attendant Access CCIS NOTE 4 LDN Night Connection CCIS Link Alarm Display CCIS Link Reconnect CCIS Message Waiting Lamp Setting Attendant CCIS NOTE 3 Message Waiting Lamp Setting Station CCIS NOTE 3 Miscellaneous Trunk Access CCIS Miscellaneous Trunk Restriction C...

Страница 33: ... available only for the SV9300 network not available for the network including the 2400 IPX SERVICES REMARKS Night Connection Fixed CCIS Night Connection Flexible CCIS Outgoing Trunk Queuing CCIS Paging Access CCIS Restriction from Outgoing Calls CCIS Service Display CCIS Single Digit Station Calling CCIS Station Controlled Conference CCIS NOTE 1 Station to Station Calling CCIS Station to Station ...

Страница 34: ...ffic between Office A and Office C is high as shown in the network of the following figure Office A and Office C should be connected by No 7 CCIS directly Network Structuring Determining Number of No 7 CCIS Routes When the system is a Main Office or a Tandem Office two or more routes to other offices are required The maximum number of No 7 CCIS routes is 8 per system Determining Type of Transmissi...

Страница 35: ... s Attendant Console cannot set this feature The SV9300 provides the feature when instructed by the Main Office Centralized Billing CCIS Centralized Fault Message Main office 2400 IPX only The SV9300 can pass information but cannot generate alarm information and send over CCIS Centralized PCPro CCIS Main office 2400 IPX only For Centralized Fault Message the SV9300 cannot generate its own fault me...

Страница 36: ...ired when deciding the Point Code 1 The same Point Code cannot be assigned to more than one office 2 A single Point Code must not be assigned to each CCIS channel in the same system When a system has two or more CCH the same Point Code originating has to be assigned to all CCH in a system 3 The maximum number of Point Codes is 256 Only 256 offices can be connected in the same network Example Point...

Страница 37: ... 00001 00002 00001 00003 Assign the Originating Point Code and the Des tination Point Code for CCH00 Assign the Originating Point Code and the Des tination Point Code for CCH01 Command Code 1st Data 2nd Data Remarks CMA7 Y 01 CMA7 Y 02 00 00 00002 00001 Assign the Originating Point Code and the Des tination Point Code for CCH00 Command Code 1st Data 2nd Data Remarks CMA7 Y 01 00 00 00003 00001 Ass...

Страница 38: ...ed through which CCH This is extremely important not only for where two switches are connected to each other but also for networks in which tandem signaling is used Example 1 Data Assignment of Office A Data Assignment of Office B Command Code 1st Data 2nd Data Remarks CMA8 00002 00003 00004 00 00 00 Assign the data to make a CCH link with Office B via CCH00 Command Code 1st Data 2nd Data Remarks ...

Страница 39: ...set up to call and signal Office B which then routes the call to Office D Data Assignment of Office A Command Code 1st Data 2nd Data Remarks CMA8 00001 00002 00004 01 01 00 Assign the data to make a CCH link with Office D via CCH00 and make a CCH link with Of fice B via CCH01 Command Code 1st Data 2nd Data Remarks CMA8 00001 00002 00003 00 00 00 Assign the data to make a CCH link with Office C via...

Страница 40: ...g station number consists of the office number assigned in CMA7 Y 06 and the station num ber assigned in CM10 Y 00 for the station time slot The terminating station number consists of the dialed number and the data assigned in CM8A any LCR changes to the number dialed Next page shows an example of the Station Number Closed Numbering and Office Code and Station Number Open Numbering respectively Co...

Страница 41: ... Office Code and Station Number Open Numbering 53 53 54 54 52 52 A B C Station Numbering Closed Numbering When originating a call from Office A to Office C 54 Station Number Office Location Number A B C Office Code and Station Number Open Numbering When originating a call from Office A to Office C Station Number Access Code 11 12 13 Office Code 13 8 ...

Страница 42: ...data assign ment of the Originating Office Number CMA7 Y 06 is not necessary because the Originating Of fice Number is included in the originating station number LCR Group 3 CM20 Y 0 3 A129 must be used for assigning an LCR access code 2 Office Code and Station Number Open Numbering The dialing number must be formed as follows a 4 digits a b 4 digits c 8 digits a1 c1 XXXXXXXX Station Number Maximu...

Страница 43: ...inguished by the 1st or 2nd digit of the dialed station number Data Assignment of Office A Command Code 1st Data 2nd Data Remarks CM20 Y 0 CM20 Y 0 CM8A Y A000 CM8A Y 4005 CM8A Y 0000 CM8A Y 5000 CM8A Y 5000 CM10 Y 00 CMA7 Y 06 CM85 Y 5 51 52 3 52 1 100 153 XXXXXX 00 52 804 A129 4005 0000 00000 NONE NONE 51XX NONE 04 4 digit station LCR Group 3 Area code Development Pattern No 5 Route Pattern 000 ...

Страница 44: ... Y 0 CM8A Y A000 CM8A Y 4005 CM8A Y 4005 CM8A Y 0000 CM8A Y 5000 CM8A Y 5000 CM10 Y 00 CMA7 Y 06 CM85 Y 5 5 3 512 513 1 100 153 XXXXXX 00 513 A129 4005 8004 0000 00000 NONE NONE 512X NONE 04 LCR Group 3 Area Code Development Pattern No 5 4 digit Intra Office Station Route Pattern 000 Route 00 access by dialing 52XX No digit addition No digit deletion Originating station number No originating offic...

Страница 45: ...0000 CM8A Y 5000 CM8A Y 5000 CM8A Y 9000 CMA7 Y 06 CM10 Y 00 CM85 Y 5 8 0 20 21 22 1 100 153 0 00 XXXXXX 21 22 A126 4005 8000 0000 0000 00000 00 NONE 8 820 21XX 07 07 LCR Group 00 Area Code Development Pattern No 5 Intra Office Termination Route Pattern No 000 Route Pattern No 000 Route 00 access by dialing 31XX 34XX Digit Addition Pattern No 00 No digit deletion Addition of digit 8 Originating of...

Страница 46: ...005 CM8A Y 0000 CM8A Y 5000 CM8A Y 5000 CMA7 Y 06 CM10 Y 00 CM85 Y 5 8 3 820 821 822 1 100 153 00 XXXXXX 821 822 A129 4005 8000 0000 0000 00000 NONE NONE 820 21XX 07 07 LCR Group 3 Area Code Development Pattern No 5 Intra Office Termination Route Pattern No 000 Route Pattern No 000 Route 00 access by dialing 31XX 34XX No digit addition No digit deletion Originating office number Originating statio...

Страница 47: ...to D 1st Choice A B D 2nd Choice A C B D Data Assignment of Office A Command Code 1st Data 2nd Data Remarks CM20 Y 0 CM8A Y A000 CM8A Y 4005 CM8A Y 0000 CM8A Y 0000 CM8A Y 5000 CM8A Y 5000 CMA7 Y 06 CMA7 Y 06 CM10 Y 00 CM85 Y 5 8 3 823 1 2 100 153 00 01 XXXXXX 823 A129 4005 0000 00000 00001 NONE NONE 820 820 21XX 07 LCR Group 3 Area Code Development Pattern No 5 Route Pattern 000 LCR Pattern 000 R...

Страница 48: ...Y 0000 CM8A Y 0000 CM8A Y 5000 CM8A Y 5000 CM8A Y 5001 CM8A Y 5001 CM8A Y 9000 CMA7 Y 06 CM10 Y 00 CM85 Y 5 CM85 Y 5 8 3 821 1 2 100 153 100 153 0 00 XXXXXX 821 516753 A129 4005 0000 00000 00101 NONE NONE 00 03 516753 821 21XX 07 10 LCR Group 3 Area Code Development Pattern No 5 Route Pattern 000 LCR Pattern 000 Route 00 LCR Pattern 001 Route 01 No digit addition No digit deletion Digit Addition P...

Страница 49: ...line route of the tandem office connected through CCIS are all busy CONDITIONS Tie Line between A and B Idle Tie Line between B and C Busy The other conditions are same as Example 2 Data Assignment of Office A The other data assignments are the same as Example 2 Command Code 1st Data 2nd Data Remarks CM08 372 0 A RT00 20 21 RT01 NO 7 CCIS C O DID LDN 516753 NO 7 CCIS 22 B C ...

Страница 50: ...must be to a tenant number equal to 01 or higher Do not use Tenant 00 2 For Attendant Console calls the tenant number transmitted to the destination SV9300 is equal to the Attendant Group 0 3 to which the attendant is assigned in CM60 Y 00 Remember that Tenant 00 is not available in the 2400 IPX so an Attendant Group of 1 3 must be used 3 For ensuring proper restriction classes throughout the netw...

Страница 51: ...cedure for CCIS You can see the sample data programming shown below Sample Data Programming for Open Numbering System Page 1 54 Sample Data Programming for Closed Numbering System Page 1 59 Page 1 68 END Inter Tenant Connection Assignment Numbering Plan Assignment Digital Trunk Data START Page 1 51 Page 1 46 Page 1 38 CCIS Feature Programming Assignment Page 1 64 Route Advance Assignment ...

Страница 52: ...unk No Assign the destination to receive the synchro nous signal for CCT 1 2 Y 10 59 01 First priority 02 Second priority 01 18 Slot No NONE No data NOTE 1 This data is assigned for the clock synchronization of SV9300 for the opposite office of ISDN network CCIS Digital Tie Line Do not assign this data for ISDN terminals NOTE 2 The second data must be assigned the Slot number to which each interfa...

Страница 53: ...1 NOTE 2 000 127 Trunk Blade No assigned by CM05 Y 1 0 Available Non Transparent 1 Not available Transparent 1 2 Y 19 Selection of cable length for CCT 000 127 Trunk Blade No assigned by CM05 Y 1 0 0 40 m 0 131 2 ft 1 41 81 m 134 5 265 7 ft 2 82 122 m 269 400 2 ft 3 123 162 m 400 4 531 4 ft 4 163 200 m 534 8 656 ft 7 0 40 m 0 131 2 ft 1 2 Y 20 Short Long mode setting of cable CCT 000 127 Trunk Bla...

Страница 54: ...10 not defined 15 0 91 1 70 V Assign a trunk route number to the CCT NOTE 1 The trunk routes used for a common signaling channel must be different from the trunk routes used for voice channels NOTE 2 If channel number 16 is assigned as Common Signaling channel all channels in the CCT must be as signed as No 7 CCIS trunk NOTE 3 The CCT route must be separated from any analog trunk route 1 2 Y 00 00...

Страница 55: ... arrives 1 2 Y 005 00 63 Trunk Route No 1 Release Signal arrives Specify the incoming connection signal 1 2 Y 009 00 63 Trunk Route No 03 Wink Start CCIS Specify the outgoing start condition 1 2 Y 020 00 63 Trunk Route No 00 Wink Start CCIS Specify the trunk seizure sequence for voice channel route 1 2 Y 083 00 63 Trunk Route No 0 As per CM08 078 1 By allotter Specify the trunk seizure sequence wh...

Страница 56: ...ot available Assign a CCH number to each common signal ing channel and voice channel route 1 2 Y 091 00 63 Trunk Route No 00 63 CCH No Assign the kind of CCIS trunk T1 to each common signaling channel and voice channel route NOTE When E1 2 Mbps is used set the second data to default NONE 1 2 Y 100 00 63 Trunk Route No 11 CCIS Trunk T1 NONE No data Assign a Circuit Identification Code CIC to each t...

Страница 57: ...1 00 63 CCH No 00001 16367 Originating Point Code Assign a Destination Point Code DPC to each CCH number NOTE The Destination Point Code is used to designate a terminating office in the No 7 CCIS network Usually a different DPC is assigned to each CCH number in the same system 1 2 Y 02 00 63 CCH No 00001 16367 DPC Assign the Point Code of the Centralized Fault Reporting office if required 1 2 Y 05...

Страница 58: ...H No 0 64 Kbps 1 56 Kbps 2 48 Kbps 1 3 48 Kbps 2 7 64 Kbps Assign the CCH number to which a signaling message is transferred according to the Desti nation Point Code DPC received Up to 256 point codes can be assigned 1 2 Y 0 00001 16367 DPC 00 63 CCH No Specify the type of the CCT blade 1 2 Y 15 000 127 Trunk Blade No by CM05 Y 1 0 E1 2 Mbps 1 T1 1 5 Mbps F CMA7 CMA8 CMAA END ...

Страница 59: ... do the following data programming DESCRIPTION DATA Reassign Highway Channel to the slot accom modated the CCT blade 1 2 Y 9 XX YY XX 01 50 Unit No YY 01 07 13 Lowest Slot No in each Line Trunk chassis 2U XX YY XX 01 50 Unit No YY 06 12 18 Highest Slot No in each Line Trunk chassis 2U Execute the blade reset to all slots of the Unit accommodated the CCT blade 1 2 Y 3 XX YY XX 01 50 Unit No YY 01 1...

Страница 60: ...Route Pattern number to the digits to be dialed in the Area Code Development Pat tern number assigned by CM8A Y A000 1 2 Y 4005 4007 Area Code Development Pattern No 5 7 X X X Area Code 1 8 digits 0000 0255 Route Pattern No 000 255 Assign an area code for intra office termina tion if required 1 2 Y 4005 4007 Area Code Development Pattern No 5 7 X X X Area Code 1 8 digits 8000 Intra Office Terminat...

Страница 61: ...ion 01 10 First 1 10 digits deletion NONE No digit deletion When sharing LCR Pattern number and LCR Pattern number for alternative routing To al low maximum 255 alternative routing offices specify to assign area code addition by CM8A Y 5000 5255 178 1 2 Y 5000 5255 LCR Pattern No 000 255 177 Sharing LCR Pattern No for alterna tive routing 0 Assigned by CM8A Y 5000 5255 178 1 Assigned by CM8A Y 500...

Страница 62: ...9000 9255 Digit Addition Pattern No 000 255 0 Entry of digit code to be added X X X Digits to be added Maximum 32 digits Specify the maximum number of dialed digits sent to the CCIS network 1 2 379 0 15 digits 1 24 digits Specify the maximum number of sending dig its dialed by the calling party The maximum number of sending digits in cluding the area codes should be assigned to each area code 1 2 ...

Страница 63: ...e for access to the desired Route Pattern number 1 2 Y 4005 4007 Area Code Development pattern No 5 7 X X X Area Code 1 8 digits 0000 0255 Route Pattern No 000 255 Assign an area code station number for intra office station if required 1 2 Y 4005 4007 Area Code Development Pattern No 5 7 X X X Area Code 1 8 digits 8001 8008 1 8 digits Intra Office Station Specify the LCR selection priority for the...

Страница 64: ...ion Pattern No 000 255 NONE No digit addition For area code addition designate the digits to be added when CM8A Y 5000 5255 177 2nd data is 0 1 2 Y 5000 5255 LCR Pattern No 000 255 178 Designation of Digit Addition Pattern No 9000 9255 Digit Addition Pattern No 000 255 NONE No digit addition 1 2 Y 9000 9255 Digit Addition Pattern No 000 255 0 Entry of digit code to be added X X X Digits to be adde...

Страница 65: ...k NOTE When linking with the 2400 IPX the tenant number for the SV9300 should be assigned as 01 63 00 is not used 1 2 Y 01 000 511 Trunk No 00 63 Tenant No 00 63 01 Tenant No 01 Specify the inter tenant connection for station to station calling or incoming call termination See Example 1 2 in the following pages 1 2 Y 1 Station to Station Calling XX ZZ XX 00 63 Tenant No of Calling Station ZZ 00 63...

Страница 66: ...on A and Station B the data assignment at Office B is as fol lows NOTE The inter tenant restriction between Trunk B and Station B CM63 Y 2 is ineffective Command Code 1st Data 2nd Data CM63 Y 1 01 02 01 Tenant No of Calling Station Station A 02 Tenant No of Called Station Station B 1 Allow TRUNK A PBX NO 7 CCIS TRUNK B STA B TENANT NO STA A A B OF STA B 02 TENANT NO OF STA A 01 OFFICE OFFICE A B ...

Страница 67: ... C Office A and Station B Office B the data assignment at Office B is as follows NOTE The inter tenant restriction between Trunk B and Station B CM63 Y 2 is ineffective Command Code 1st Data 2nd Data CM63 Y 2 01 02 01 Tenant No of Called Station Station B 02 Tenant No of Trunk Trunk C 1 Allow NO 7 CCIS TRUNK B STA B TENANT NO TENANT NO OF TRUNK C 01 OF STA B 02 TRUNK A TRUNK C OFFICE B OFFICE A ...

Страница 68: ...TRK002 CIC 2 RT11 31xx CIC 1 RT10 32xx TRK003 TRK004 TRK005 CIC 2 RT13 CIC 1 RT12 21xx CIC 1 CIC 2 34xx 35xx OFFICE C PC 00020 OFFICE NO 825 CCT1 CCT0 OFFICE A PC 00001 OFFICE NO 820 OFFICE B PC 00010 OFFICE NO 822 CONDITIONS Open Numbering 4 digit Station No Centralized Billing Not provided Trunk Blade No of CCT on OFFICE A EXAMPLE CCT0 000 CCT1 001 CCH00 CCH01 ...

Страница 69: ...ssignments are only for 24CCT 3 Assign a trunk route number to the CCT trunks Command Code 1st Data 2nd Data 05 Y 0 010101 42 CCT0 010201 42 CCT1 05 Y 1 010101 000 Trunk Blade No 000 010201 001 Trunk Blade No 001 Command Code 1st Data 2nd Data AA Y 00 000 0 001 0 AA Y 01 000 0 1 001 0 1 AA Y 02 000 0 001 0 Command Code 1st Data 2nd Data 30 Y 00 000 10 RT10 001 10 002 11 RT11 003 12 RT12 004 12 005...

Страница 70: ...gnment 11 04 12 04 13 04 35 Y 001 10 7 Dialing signal type 11 7 12 7 13 7 35 Y 004 10 2 Answer Signal 11 2 12 2 13 2 35 Y 005 10 1 Release Signal 11 1 12 1 13 1 35 Y 009 10 03 Incoming connection signal 11 03 12 03 13 03 35 Y 020 10 00 Sender start condition 11 00 12 00 13 00 35 Y 090 10 0 No 7 CCIS facilities assignment 11 0 12 0 13 0 Command Code 1st Data 2nd Data 35 Y 091 10 00 CCH 00 11 00 12 ...

Страница 71: ... 002 CIC2 003 001 CIC1 004 002 CIC2 Command Code 1st Data 2nd Data A7 Y 00 00 002 Common Signaling Channel assignment 01 005 A7 Y 01 00 00001 Originating Point Code OPC assignment 01 00001 A7 Y 02 00 00010 Destination Point Code DPC assignment 01 00020 A7 Y 06 00 0820 Originating Office number assignment 01 0820 A8 Y 0 00010 00 Destination Point Code DPC to which a signaling message is transferred...

Страница 72: ...ill be heard after 8 is dialed 8 will be added and sent to distant PBX Command Code 1st Data 2nd Data 20 Y 0 8 A126 Access Code 8 8A Y A000 0 4005 Area Code Development Pattern No 5 8A Y 4005 22 0000 Route Pattern 000 25 0001 Route Pattern 001 8A Y 0000 1 00010 Trunk Route 10 8A Y 0001 1 00012 Trunk Route 12 8A Y 5000 100 9000 Digit Addition Pattern No 000 8A Y 9000 0 8 Addition of digit 8 85 Y 5 ...

Страница 73: ... 00001 OFFICE NO 21 21xx OFFICE B PC 00010 OFFICE NO 22 CCT0 CCH00 TRK000 TRK001 TRK002 CCT1 CCH01 TRK003 TRK004 TRK005 CIC 1 CIC 2 CIC 1 CIC 2 RT10 RT11 RT12 RT13 CIC 1 CIC 2 CIC 1 CIC 2 22xx 25xx OFFICE C PC 00020 OFFICE NO 25 CONDITIONS Closed Numbering 4 digit Station No Centralized Billing Not provided Trunk Blade No of CCT on OFFICE A CCT0 000 CCT1 001 ...

Страница 74: ...ignments are only for 24CCT 3 Assign a trunk route number to the CCT trunks Command Code 1st Data 2nd Data 05 Y 0 010101 42 CCT0 010201 42 CCT1 05 Y 1 010101 000 Trunk Blade No 000 010201 001 Trunk Blade No 001 Command Code 1st Data 2nd Data AA Y 00 000 0 001 0 AA Y 01 000 0 1 001 0 1 AA Y 02 000 0 1 001 0 1 Command Code 1st Data 2nd Data 30 Y 00 000 10 RT10 001 10 002 11 RT11 003 12 RT12 004 12 0...

Страница 75: ...ssignment 11 04 12 04 13 04 35 Y 001 10 7 Dialing signal type 11 7 12 7 13 7 35 Y 004 10 2 Answer Signal 11 2 12 2 13 2 35 Y 005 10 1 Release Signal 11 1 12 1 13 1 35 Y 009 10 03 Incoming connection signal 11 03 12 03 13 03 35 Y 020 10 00 Sender start condition 11 00 12 00 13 00 35 Y 090 10 0 No 7 CCIS facilities assignment 11 0 12 0 13 0 Command Code 1st Data 2nd Data 35 Y 091 10 00 CCH 00 11 00 ...

Страница 76: ... Data 30 Y 035 000 001 CIC1 001 002 CIC2 003 001 CIC1 004 002 CIC2 Command Code 1st Data 2nd Data A7 Y 00 00 002 Common Signaling Channel assignment 01 005 A7 Y 01 00 00001 Originating Point Code OPC assignment 01 00001 A7 Y 02 00 00010 Destination Point Code DPC assignment 01 00020 A8 Y 0 00010 00 Destination Point Code DPC to which a signaling message is transferred 00020 01 ...

Страница 77: ...ard No digits will be added Command Code 1st Data 2nd Data 20 Y 0 22 A129 Access Code 22 20 Y 0 25 A129 Access Code 25 8A Y A000 3 4007 Area Code Development Pattern No 7 8A Y 4007 22 0000 Route Pattern 000 22XX 25 0001 Route Pattern 001 25XX 8A Y 0000 1 00010 Route 10 access by 22XX 8A Y 0001 1 00012 Route 12 access by 25XX 20 Y 0 21 804 4 digits station for originating station No 85 Y 5 22 04 Ma...

Страница 78: ...ative Routing of CCIS outgoing call when all outgoing trunks of tandem office are busy 1 2 372 0 To provide 1 Not provided Set the PBR timer when establishing a tandem connection NOTE Usually it is recommended to set the second data to 33 33 sec 1 2 Y 0 104 02 99 02 99 seconds 1 second increments If no data is set the default setting is 7 seconds Assign a Numbering Plan Group to each ten ant 1 2 0...

Страница 79: ...Route Pattern No 000 255 Assign a LCR Pattern number to each area code for the Area Code Development Pattern number assigned by CM8A Y A000 1 2 Y 4005 4007 Area Code Development Pattern No 5 7 X X Area Code Maximum 8 digits 5000 5255 LCR Pattern No 000 255 For area code deletion designate the digits to be not deleted 1 2 Y 5000 5255 LCR Pattern No 000 255 152 Deletion of all digits of the area cod...

Страница 80: ...ing digits in cluding the area codes should be assigned to each area code 1 2 Y 5 7 Area Code Development Pattern No 5 7 assigned by CM8A Y A000 X X X Area code dialed Maximum 8 digits 01 24 1 digit 24 digits 25 79 25 digits 79 digits Assign an ACM signal waiting timer after sending IAI signal in the outgoing calls via CCIS to CCH number 1 2 Y 10 00 63 CCH No 01 14 2 28 seconds 2 second increments...

Страница 81: ... this detouring feature for the systems do the following programming to the incoming office In outgoing office program the data for providing the Alternative Routing in advance DESCRIPTION DATA Provide the system with the alternative routing when all outgoing trunks of incoming office is in the make busy condition NOTE The make busy condition means when the CME5 Y 1 is set to 0 1 2 624 0 To provid...

Страница 82: ...owing features require no programming Attendant Controlled Conference CCIS Call Processing Indication CCIS Called Station Status Display CCIS Digital Display Station CCIS Digital Display Trunk CCIS Elapsed Time Display CCIS Hands Free Answerback CCIS Individual Attendant Access CCIS Service Display CCIS Station Controlled Conference CCIS Station to Station Calling Operator Assistance CCIS ...

Страница 83: ...ION DATA Assign the access code for LCR Group 3 NOTE When providing Attendant Camp On with Tone Indication CCIS be sure to set the second data to A129 LCR Group 3 1 2 Y 0 3 Numbering Plan Group 0 3 X XXXX Access Code A129 LCR Group 3 Specify the Camp On Tone sent to busy sta tion 1 2 068 0 Camp on Tone is sent out only the first once 1 Camp on Tone is repeated at 4 second intervals Allow the conne...

Страница 84: ...ation number at another switching office and receive busy tone 2 Press the RELEASE key 3 A Camp On tone is sent to the busy station and Camp On is set To cancel an Attendant Camp On with Tone Indication CCIS from an Attendant Console 1 Press the LOOP key corresponding to the held call and connect to the waiting trunk party 2 Press the DEST key and receive busy tone 3 Press the CANCL key DESCRIPTIO...

Страница 85: ...anual operation is required DESCRIPTION DATA Specify the timing for Automatic Recall If no data is set the following timing will be applied Attendant Recall 31 2 33 6 seconds Non Exclusive Hold 60 64 seconds Exclusive Hold 236 240 seconds Transfer Recall 24 28 seconds Attendant Hold Recall 31 2 33 6 seconds Camp On Recall 24 32 seconds 1 2 1 2 Y 0 00 Attendant Recall 01 14 2 4 33 6 seconds 2 4 sec...

Страница 86: ...t No X XXXXXXXX Virtual Line station No Assign the Hot Line to the Virtual Line stations assigned by CM11 1 2 Y 03 X XXXXXXXX Virtual Line station No 04 Hot Line Allocate the memory area for the Hot Line Outside call For example to assign the 10 Hot Line Out side calls into No 100 through No 109 Mem ory Slots 2nd data is 100010 Abbreviated Codes are automatically assigned as shown be low 1 2 65 Fo...

Страница 87: ...y PCPro CAT Maximum 16 char acters Assign the Hot Line pairs Bidirectional Hot Line should be assigned as follows Hot Line Pair No Calling Side Called Side 00 Station A Station B 01 Station B Station A NOTE 1 Up to 100 Hot Line stations 50 pair can be set 1 2 Y 00 99 Hot Line pair No 0 Calling Station 1 Called Station Station No E00X X 0 7 DESKCON No assigned by CM10 Y 00 CXX For Called Outside pa...

Страница 88: ...r press the Speaker key 2 Press the line feature key associated with the preassigned station The destination station is automatically dialed ring back tone is heard and the destination station answers 3 After completion of conversation hang up or press the Speaker key To make another Brokerage Hot Line CCIS call immediately press another line feature key without going on hook and off hook ...

Страница 89: ...SS key allows a direct access to the preprogrammed station within the CCIS network Station Application All Multiline Terminals with DSS keys and the associated LEDs and DSS BLF Console STATION Office A CCIS SV9300 Office B SV9300 CCIS Office C SV9300 BLF Message Sending Office BLF Message Receiving Office Destination No 1 Destination No 0 DSS Console Multiline Terminal BLF Message BLF Message One ...

Страница 90: ... message via CCIS A maximum of 8 destinations Destination No 0 7 can be set per system 1 2 Y 08 0 7 Destination No 0 7 assigned by CM12 Y 30 37 00001 16367 DPC When the CCIS network adopts Open Num bering system assign the access code and of fice number of own office to be added to the station number for sending the BLF message 1 2 Y 07 0 X XXXX Access Code Originating Of fice No X 0 9 A B NOTE Am...

Страница 91: ...ion number For open numbering system Access code of fice number station number 1 2 0000 0999 Virtual Port No X XXXXXXXX Station No NOTE Amount of Access Code Office No Station No must be no more than 8 digits Specify whether the station number assigned by CM11 is own office station or the other of fice station 1 2 Y 40 X XXXXXXXX Station No assigned by CM11 0 Other office station 1 Own office stat...

Страница 92: ...0 1 Facility for programming the dialed number from the station Effective Ineffec tive NONE No data NOTE For 1000 Slot Memory Block to which any data is not assigned by CM73 Y 0 allocate a station based memory area using this command Specify whether the line lockout indication is available on the DSS Console 1 2 274 0 Available 1 Not available A CM94 0 9 1 Memory Parcel 00 99 01 10 Slot Memory Blo...

Страница 93: ...Operating Procedure To initiate a call 1 Press the desired DSS key 2 Lift the handset and converse when party answers OR 1 Lift the handset and receive dial tone 2 Press the desired DSS key 3 Converse when party answers To display Busy or Line Lockout status No manual operation is required ...

Страница 94: ... burst tone Other than New Zealand One burst tone New Zealand Only 1 2 046 0 Not sent 1 To send Specify the Warning Tone sent to connected parties 1 2 045 0 Only the first once 1 Every 4 seconds Specify whether the Warning Tone is sent to C O line when a station operator overrides a busy station which is connected to a C O line 1 2 076 0 To send 1 Not sent Assign Service Restriction Class A to the...

Страница 95: ...rating Procedure To activates a Busy Verification CCIS 1 Press an idle LOOP key 2 Dial the desired station number and receive busy tone 3 Press the BV key 4 A two burst tone is sent to connected parties 5 The Attendant may monitor or join the conversation 6 Press the RELEASE key to disengage ...

Страница 96: ...ble Programming DESCRIPTION DATA Assign Service Restriction Class A to the re quired stations 1 2 Y 02 X XXXXXXXX Station No XX ZZ XX 00 15 Service Restriction Class A Allow Call Back in Service Restriction Class A assigned by CM12 Y 02 1 2 Y 003 00 15 Service Restriction Class A assigned by CM12 Y 02 1 Allow Assign the access code for Call Back 1 2 Y 0 3 Numbering Plan Group 0 3 X XXXX Access Cod...

Страница 97: ...ng station answers the originally called station will ring To cancel Call Back CCIS from a Single Line Telephone 1 Lift the handset and receive dial tone 2 Dial the Call Back cancellation code and receive Service Set Tone Multiline Terminal To set Call Back CCIS from a Multiline Terminal 1 Dial the desired station number and receive busy tone 2 Press the Call Back feature key and receive Service S...

Страница 98: ... ring 6 The originally called station s LCD shows To cancel a Call Back CCIS from a Multiline Terminal 1 Lift the handset or press the Speaker key and receive dial tone 2 Press the Call Back feature key and receive Service Set Tone The feature is canceled 3 The LCD shows Called station number is displayed XXXX TIME DISPLAY CANCEL XXXX TIME DISPLAY ...

Страница 99: ...iction Class A Allow Call Forwarding All Calls and Call For warding All Calls Outside in Service Restric tion Class A assigned by CM12 Y 02 NOTE When providing Call Forwarding All Calls Outside set 1 Allow for Y 000 Y 026 of CM15 1 2 Y 000 Call Forwarding All Calls Y 026 Call Forwarding All Calls Outside 00 15 Service Restriction Class A assigned by CM12 Y 02 1 Allow Assign an access code for Call...

Страница 100: ...st forwarding number via CCIS 1 The second forwarding number of own office Assign whether an extension can set the desti nation of Call Forwarding All Calls Outside by entering only a trunk access code 1 2 386 0 Restricted 1 Allowed Allow or restrict Multiple Call Forwarding All Calls Busy Line No Answer CCIS for each CCH number 1 2 Y 29 00 63 CCH No 0 Allowed Maximum 7 times 1 Restricted Only onc...

Страница 101: ...CIS DESCRIPTION DATA Select the Dial Tone on setting Call Forward ing All Calls 1 2 Y 2 13 Dial Tone on Setting Call Forwarding All Calls 0 Special Dial Tone 1 Dial Tone Assign the Call Forwarding All Calls key to a Multiline Terminal if desired 1 2 Y 00 My Line No Key No F0010 Call Forwarding All Calls Set Can cel B CM48 CM90 END ...

Страница 102: ...ed on the LCD of the forwarding destination Multiline Terminal To provide this feature do the following programming On the forwarded destination side PBX PBX B DESCRIPTION DATA Assign Service Restriction Class C to the re quired stations 1 2 Y 07 X XXXXXXXX Station No XX 00 15 Service Restriction Class C PBX A PBX B STATION TRUNK CCIS STATION 2000 Kind of Call Forwarding Call Forwarding All Calls ...

Страница 103: ...N DATA Specify to display the first forwarding station number via CCIS or the second forwarding sta tion number of own office on LCD of forward ing destination Multiline Terminal NOTE In the case of not forwarding via CCIS the number to be displayed on LCD is always forwarding number of own office regardless of setting 2nd data 0 1 2 564 0 The first forwarding number via CCIS 1 The second forwardi...

Страница 104: ...Dial the Call Forwarding All Calls cancellation code and receive Service Set Tone Attendant Console To set a Call Forwarding All Calls CCIS from an Attendant Console 1 Press an idle LOOP key 2 Dial the Call Forwarding All Calls feature access code and receive Feature Dial Tone 3 Dial the originating station number 4 Dial the outgoing trunk access code and receive a single burst of Service Set Tone...

Страница 105: ...k using Open Numbering Plan 4 Dial the desired target station number and receive Service Set Tone 5 Wait approximately five seconds and receive Service Set Tone The LED lights and the LCD shows 6 Replace the handset or press the Speaker key To cancel a Call Forwarding All Calls CCIS from a Multiline Terminal 1 Lift the handset or press the Speaker key and receive dial tone 2 Press the Call Forward...

Страница 106: ...ne Outside in Service Re striction Class A assigned by CM12 Y 02 NOTE When providing Call Forwarding Busy Line Outside set 1 Allow for Y 011 Y 028 Y 012 Y 029 of CM15 1 2 Y 011 Call Forwarding Busy Line Y 028 Call Forwarding Busy Line Outside Y 012 Call Forwarding Busy Line No Answer Y 029 Call Forwarding Busy Line Outside No Answer Outside 00 15 Service Restriction Class A assigned by CM12 Y 02 1...

Страница 107: ...unting group is set Do Not Dis turb Specify whether to transfer to the destina tion of Call Forwarding Busy Line or of Do Not Disturb by CM51 Y 10 when the station is set Do Not Disturb during setting Call For warding Busy Line 1 2 240 0 To prioritize Station Hunting To the destination of Call Forwarding Busy Line 1 To prioritize Do Not Disturb To the destination of Do Not Disturb by CM51 Y 10 Ass...

Страница 108: ...1 2 Y 23 Internal Call or ATT assisted call Y 24 C O Incoming Call Y 25 Tie Line Incoming Call 00 63 Tenant No 1 Call Forwarding Busy Line Assign the Call Forwarding Busy Line key to a Multiline Terminal if desired 1 2 Y 00 My Line No Key No F0014 Call Forwarding Busy Line Set Cancel For setting the same key as Call Forwarding No Answer 1 2 My Line No Key No F0012 Call Forwarding No Answer Busy Li...

Страница 109: ...ed on the LCD of the forwarding destination Multiline Terminal To provide this feature do the following programming On the forwarded destination side PBX PBX B DESCRIPTION DATA Assign Service Restriction Class C to the re quired stations 1 2 Y 07 X XXXXXXXX Station No XX 00 15 Service Restriction Class C PBX A PBX B STATION TRUNK CCIS STATION 2000 Kind of Call Forwarding Call Forwarding All Calls ...

Страница 110: ...N DATA Specify to display the first forwarding station number via CCIS or the second forwarding sta tion number of own office on LCD of forward ing destination Multiline Terminal NOTE In the case of not forwarding via CCIS the number to be displayed on LCD is always forwarding number of own office regardless of setting 2nd data 0 1 2 564 0 The first forwarding number via CCIS 1 The second forwardi...

Страница 111: ...al tone 2 Dial the Call Forwarding Busy Line cancellation code and receive Service Set Tone Attendant Console To set a Call Forwarding Busy Line CCIS from an Attendant Console 1 Press an idle LOOP key 2 Dial the Call Forwarding Busy Line feature access code and receive Feature Dial Tone 3 Dial the originating station number 4 Dial the outgoing trunk access code and receive a single burst of Servic...

Страница 112: ...rk using Open Numbering Plan 4 Dial the desired target station number and receive Service Set Tone 5 Wait approximately five seconds and receive Service Set Tone The LED lights and the LCD shows 6 Replace the handset or press the Speaker key To cancel Call Forwarding Busy Line CCIS from a Multiline Terminal 1 Lift the handset or press the Speaker key and receive dial tone 2 Press the Call Forwardi...

Страница 113: ...nswer and Call Forwarding No Answer Outside in Service Restriction Class A assigned by CM12 Y 02 When providing Call Forwarding No Answer Outside set 1 Allow for Y 010 Y 027 of CM15 1 2 Y 010 Call Forwarding No Answer Y 027 Call Forwarding No Answer Outside Y 012 Call Forwarding Busy Line No Answer Y 029 Call Forwarding Busy Line Outside No Answer Outside 00 15 Service Restriction Class A assigned...

Страница 114: ...operation when terminating a DID call to station with Call Forwarding No Answer set to a busy destination station Des tination station has no call forwarding set 1 2 449 0 Ring continuously at forwarded DID station 1 Drop to busy signal after time set by CM41 Y 0 01 Assign whether an extension can set the desti nation of Call Forwarding No Answer Outside by entering only a trunk access code 1 2 38...

Страница 115: ... a trunk incoming call 1 2 Y 0 01 01 30 4 120 seconds 4 second increments If no data is set the default setting is 32 36 sec onds Specify the timing for Call Forwarding No Answer for an internal call or an assisted call 1 2 Y 0 15 01 30 4 120 seconds 4 second increments If no data is set the default setting is 32 36 sec onds Assign the Call Forwarding No Answer key to a Multiline Terminal if desir...

Страница 116: ...ed on the LCD of the forwarding destination Multiline Terminal To provide this feature do the following programming On the forwarded destination side PBX PBX B DESCRIPTION DATA Assign Service Restriction Class C to the re quired stations 1 2 Y 07 X XXXXXXXX Station No XX 00 15 Service Restriction Class C PBX A PBX B STATION TRUNK CCIS STATION 2000 Kind of Call Forwarding Call Forwarding All Calls ...

Страница 117: ...N DATA Specify to display the first forwarding station number via CCIS or the second forwarding sta tion number of own office on LCD of forward ing destination Multiline Terminal NOTE In the case of not forwarding via CCIS the number to be displayed on LCD is always forwarding number of own office regardless of setting 2nd data 0 1 2 564 0 The first forwarding number via CCIS 1 The second forwardi...

Страница 118: ...2 Dial Call Forwarding No Answer cancellation code and receive Service Set Tone Attendant Console To set a Call Forwarding No Answer CCIS from an Attendant Console 1 Press an idle LOOP key 2 Dial the Call Forwarding No Answer feature access code and receive Feature Dial Tone 3 Dial the originating station number 4 Dial the outgoing trunk access code and receive a single burst of Service Set Tone T...

Страница 119: ...ork using Open Numbering Plan 4 Dial the desired target station number and receive Service Set Tone 5 Wait approximately five seconds and receive Service Set Tone The LED lights The LCD shows 6 Replace the handset or press the Speaker key To cancel a Call Forwarding No Answer CCIS from a Multiline Terminal 1 Lift the handset or press the Speaker key and receive dial tone 2 Press the Call Forwardin...

Страница 120: ...alls to an inoperative number through a CCIS trunk to be intercepted and automati cally routed to a recorded announcement informing the caller that an inoperative number was dialed and giving the Listed Directory Number for information TEL PUBLIC NETWORK MAIN OFFICE DIGITAL ANNOUNCEMENT TRUNK BLADE SATELLITE OFFICE TEL TEL PUBLIC NETWORK TRIBUTARY OFFICE C 6789 B 4567 ...

Страница 121: ... Restriction Class A assigned by CM12 Y 02 1 Allow Set the function to each Voice Response Sys tem accommodated into the system For Intercept Announcement only 1 2 Y 00 000 015 VRS No 0A00 Call Forwarding Intercept Announcement Assign a destination for the intercepted call for each tenant 1 2 Y 07 00 63 Tenant No EB000 EB015 Voice Response System No X XXXXXXXX Station No E000 Attendant Console To ...

Страница 122: ...General Description This feature allows a target station user Station A to call a station Station B which has Call Forwarding All Calls CCIS set Programming Operating Procedure No manual operation is required DESCRIPTION DATA Assign Call Forwarding Override CCIS 1 2 371 0 Not available BT connection 1 Available START CM08 END ...

Страница 123: ...riction Class A assigned by CM12 Y 02 1 2 Y 022 00 15 Service Restriction Class A assigned by CM12 Y 02 1 Allow Assign Service Restriction Class C to the required stations 1 2 Y 07 X XXXXXXXX Station No XX 00 15 Service Restriction Class C Allow switch hook flash capability during C O line connection in Service Restriction Class C assigned by CM12 Y 07 1 2 Y 090 091 00 15 Service Restriction Class...

Страница 124: ...rd party and receive ringback tone 3 Wait for the third party to answer and announce the transfer while keeping the first party on Con sultation Hold All Calls CCIS When the station user hangs up the first and third parties will be automatically connected DESCRIPTION DATA Specify Call Transfer from a station before a called station answers 1 2 062 0 Not available 1 Available When a station that ha...

Страница 125: ...nk to Trunk Transfer in Service Restriction Class A assigned by CM12 Y 02 1 2 Y 022 00 15 Service Restriction Class A assigned by CM12 Y 02 1 Allow Assign Service Restriction Class C to the required stations 1 2 Y 07 X XXXXXXXX Station No XX 00 15 Service Restriction Class C Allow switch hook flash capability during C O line connection in Service Restriction Class C assigned by CM12 Y 07 1 2 Y 090...

Страница 126: ...cess code 3 The ATND lamp on the Attendant Console flashes and the buzzer sounds The station receives ringback tone To answer from the Attendant Console 1 Refer to the Attendant Console User s Guide If the station wishes to return to the Central Office trunk call while the Attendant Console is being called 2 Press the hookswitch momentarily The ATND lamp on the Attendant Console goes out and the b...

Страница 127: ...later 1 6 seconds later Specify the duration to display the name 1 2 121 0 Until call finished 1 As per CM08 120 Specify the duration of displaying the caller in formation when the incoming outgoing call is answered by the destination via CCIS 1 2 580 0 6 seconds 1 Until call is finished Assign the access code for station user name entry from an individual station 1 2 Y 0 3 Numbering Plan Group 0 ...

Страница 128: ...rting a blank space as the first character will cancel the existing name DESCRIPTION DATA Enter the desired user s name to each station number with Character Codes or characters 1 2 Y 0 By Character Code X XXXXXXXX Station No assigned by CM10 Virtual station No assigned by CM11 20 7F Character Code Maximum 32 digits See CM77 in the Command Manual NONE No data 1 2 Y 1 By Character X XXXXXXXX Statio...

Страница 129: ...Chapter 1 CCIS FEATURES 1 115 NWA 088654 001 Rev 1 0 94ch1003 fm CALLING NAME DISPLAY CCIS Operating Procedure No manual operation is required ...

Страница 130: ...ber sent from the network over CCIS can be displayed on the LCD of the station of another office over CCIS and can be sent to the SMDR It can also be sent to the MCI if the system pro vides the MCI with ANI Programming DESCRIPTION DATA Provide the system with Caller ID Display fea ture for CCIS calls for Office A and B 1 2 379 1 To provide Specify the duration of displaying the caller in formation...

Страница 131: ...mber with Name Dis play CCIS feature for Office A and B 1 2 Y 26 00 63 CCH No 1 To provide Provide the CCH number with Calling Party Information transferring service for Office A and B 1 2 Y 28 00 63 CCH No 1 To provide Provide the sending of calling station number or calling party number to the analog telephone for Caller ID Station when an incoming call is terminated via CCIS NOTE The sending of...

Страница 132: ... number will be displayed on the Station 301 When the call from the network terminates to the Station 200 on the Office A and be forwarded to the Sta tion 300 on Office B the calling party number will be displayed on the Station 300 ISDN CPN Caller ID T1 ANI Office A Office B Calling Party Number CCIS 300 200 The calling party number can be displayed Transfer ISDN CPN Caller ID T1 ANI Office A Off...

Страница 133: ...k are not available for the sending number 1 2 Y 12 X XXXXXXXX Station No X XXXX Sending No Assign the Local Office Code Table number 1 2 Y 13 X XXXXXXXX Station No 00 14 Local Office Code Table No 00 14 Assign the Local Office Code sent to the net work is not available for the sending number 1 2 Y 05 00 14 Local Office Code Table No 00 14 X XXX Local Office Code Maximum 12 digits Office B Office ...

Страница 134: ...e LCR Add the calling party number for ISDN calls via CCIS route 1 2 Y 5000 5255 LCR Pattern No 000 255 165 Caller ID of outgoing call by CCIS 0 To add Provide the system with Caller ID Display fea ture for CCIS calls 1 2 379 1 To provide Provide each CCH number with Name Display CCIS feature 1 2 Y 26 00 63 CCH No 1 To provide Provide the CCH number with Calling Party Information transferring serv...

Страница 135: ...h Caller ID Display fea ture for CCIS calls 1 2 379 1 To provide Provide each CCH number with Name Dis play CCIS feature 1 2 Y 26 00 63 CCH No 1 To provide Provide the CCH number with Calling Party Information transferring service 1 2 Y 28 00 63 CCH No 1 To provide Provide the Calling Party Information transfer ring service to the ISDN route 1 2 Y 145 00 63 Trunk Route No 0 To provide START CM08 C...

Страница 136: ... to direct it to the associated center office Billing information is then forwarded to the central billing center via RS 232C interface or LAN interface SMDR on RS 232C connection SMDR on IP connection CCT LOCAL OFFICE TANDEM OFFICE CCT CCT CENTER OFFICE CCT CPU BUILT IN SMDR CPU BUILT IN SMDR CPU SMDR TERMINAL CCT LOCAL OFFICE TANDEM OFFICE CCT CCT CENTER OFFICE LAN CCT CPU BUILT IN SMDR CPU BUIL...

Страница 137: ...Programming Summary END Page 1 124 Page 1 130 LAN Interface RS 232C Interface RS 232C Interface or LAN Interface START Center Office Local Office Tandem Office or Center Office Local Office Tandem Office SMDR on Programming SMDR on IP Programming RS 232C Built in SMDR Programming Page 1 127 ...

Страница 138: ...system clock data 1 2 0 Calendar Year 2014 2099 Ex 2014 1 2 1 Date MM DD WW MM 01 12 Month DD 01 31 Date WW 00 Sun 01 Mon 02 Tue 03 Wed 04 Thu 05 Fri 06 Sat 1 2 2 Time HH MM SS HH 00 23 Hour MM 00 59 Minute SS 00 59 Second Provide the system with Centralized Billing CCIS for Center Office 1 2 368 0 To provide Do not provide the system with Centralized Billing CCIS for Local Office 1 2 378 1 Not pr...

Страница 139: ...CPU blade RS port NOTE Only Unit01 can be assigned for built in SMDR 1 2 Y 00 0 Unit01 Port 1 1 Unit01 Port 2 14 Built in SMDR To change the interface condition of each port set by CM40 Y 00 assign the attribute data according to the SMDR terminal specifica tions 1 2 Y 01 Data Length 0 Unit01 Port 1 1 Unit01 Port 2 0 7 bits 1 8 bits 1 2 Y 02 Parity Check 0 Unit01 Port 1 1 Unit01 Port 2 0 Effective...

Страница 140: ...0 94ch1004 fm CENTRALIZED BILLING CCIS DESCRIPTION DATA 1 2 Y 06 RTS Signal 0 Unit01 Port 1 1 Unit01 Port 2 0 Low 1 High 1 2 Y 08 Data Speed 0 Unit01 Port 1 1 Unit01 Port 2 1 1200 bps 2 2400 bps 3 4800 bps 4 9600 bps 5 19200 bps NONE 9600 bps B CM40 END ...

Страница 141: ...anual DESCRIPTION DATA Assign the system clock data 1 2 0 Calendar Year 2014 2099 Ex 2014 1 2 1 Date MM DD WW MM 01 12 Month DD 01 31 Date WW 00 Sun 01 Mon 02 Tue 03 Wed 04 Thu 05 Fri 06 Sat 1 2 2 Time HH MM SS HH 00 23 Hour MM 00 59 Minute SS 00 59 Second Assign the IP Address for the system NOTE The second data must be entered including the periods 1 2 Y 0XX Maintenance Port 0 Unit No 01 50 1XX ...

Страница 142: ...when setting the Default Gateway Address by this command Only one Default Gateway Address can be set for the system Set the Default Gateway Address to the Maintenance port Y 0XX when not using VoIPDB Set the Default Gateway Address to the VOIP port Y 1XX when using VoIPDB 1 2 Y 0XX Maintenance Port 0 Unit No 01 50 1XX VOIP Port 1 Unit No 01 50 02 XXX XXX XXX XXX 0 0 0 1 255 255 255 254 Default Gat...

Страница 143: ...al Office Assign the billing office number if required 1 2 Y 07 00 63 CCIS channel No 0 9999 Billing Office No Provide the destination to send a billing infor mation which received from Local Office 1 2 Y 01 06 0 SMDR terminal via LAN port Specify whether the parity check is provided 1 2 827 0 Not Provided None parity 1 To provide Parity as for CM08 828 Specify the kind of parity 1 2 828 0 Odd par...

Страница 144: ...ed Billing CCIS NOTE When the network adopts Open Numbering Plan set the office num ber by CMA7 Y 06 1 2 801 0 To send 1 Not sent Specify the Kind of Center Office for Central ized Billing CCIS NOTE This command is available in fol lowing conditions Output Message Format of SMDR NEAX 2400 IMS Extended Format Local Office SV8300 SV9300 1 2 830 0 SV8300 SV9300 1 2400 IPX Assign the data as follows 1...

Страница 145: ...ndem Call through CCIS Page 1 133 1 2 377 0 Station No and Office No 1 Trunk Route No Specify the station number sent to the 2400 IPX through CCIS for SMDR NOTE 1 If the Center Office is the 2400 IPX CM65 Y 26 is required NOTE 2 When setting Name Display to Sub Line whether to display My Line No Name or Sub Line No Name depends on CM08 502 Set this data to the same setting of CM08 502 ex When CM65...

Страница 146: ...Code Provide SMDR service for incoming calls to the required trunk routes 1 2 Y 049 00 63 Trunk Route No 0 To provide DESCRIPTION DATA Specify the SRAM billing information which is sent to a destination SMDR terminal 1 2 Y 65 00 Trunk Route No 01 Station to station call 02 Outgoing trunk call 03 Abandoned outgoing trunk call 04 Incoming trunk call 05 Abandoned incoming trunk call 06 Abandoned inco...

Страница 147: ... made the call in Office A Data Assignment of Office B CM08 040 1 Provides SMDR service for tandem calls CM08 377 0 Provides office number and station number from the tandem office CM35 Y 014 C O Route No 1 To provide Data Assignment of Office A CM35 Y 014 CCIS Route No 0 Not provided CMA7 Y 06 CCH No 0000 9999 Originating Office Number Data Assignment of Office A ARTD CDN 10 CCIS Route No 0 C O S...

Страница 148: ...A CM08 040 1 Provides SMDR service for tandem calls CM08 377 0 Provides office number and station number from the tandem office CM35 Y 014 C O Route No 0 Not provided Data Assignment of Office A ARTD CDN 10 CCIS Route No 0 ARTD CDN 16 CCIS Route No 0 Data Assignment of Office B CM08 378 1 Not provided C O SMDR Terminal Office B SV8300 SV9300 Office A SV8300 SV9300 2400 IPX ...

Страница 149: ...Command Code 1st Data 2nd Data Remarks CMA7 Y 03 CMA7 Y 04 00 00 0 00003 To Center Office Command Code 1st Data 2nd Data Remarks CMA7 Y 03 CMA7 Y 04 00 00 1 00003 To Local Office CMA7 Y 03 CMA7 Y 04 01 01 0 00003 To Center Office OFFICE A OFFICE B OFFICE C CCH00 CCH00 CCH01 SMDR PC 00001 OFFICE NO 821 PC 00002 OFFICE NO 822 PC 00003 OFFICE NO 823 PC Point Code CCH Common Channel Handler ...

Страница 150: ...erating Procedure No manual operation is required The call record outputs are produced automatically Command Code 1st Data 2nd Data Remarks CMA7 Y 06 00 821 Command Code 1st Data 2nd Data Remarks CMA7 Y 06 CMA7 Y 06 00 01 822 822 OFFICE A OFFICE B OFFICE C CCH00 CCH00 CCH01 SMDR PC 00001 OFFICE NO 821 PC 00002 OFFICE NO 822 PC 00003 OFFICE NO 823 PC Point Code CCH Common Channel Handler ...

Страница 151: ...ramming is required DESCRIPTION DATA Assign as ineffective Trunk Restriction Class change by NT Night switch on DESKCON NOTE A reset by CM60 Y 90 0 0 is required after this data setting 1 2 Y 02 0 7 DESKCON No 1 Ineffective Assign as ineffective outgoing call restriction on Night Mode by NT switch on DESKCON NOTE A reset by CM60 Y 90 0 0 is required after this data setting 1 2 Y 04 0 7 DESKCON No ...

Страница 152: ... XX 01 50 Unit No YY 01 18 Slot No ZZ 01 32 Circuit No X XXXXXXXX Station No Assign the Kind of PGD 2 U10 station NOTE 1 Set the second data to 1 when combining external relay with pag ing Set the second data to 3 only when using this feature NOTE 2 When this command is set PGD 2 U10 needs to reset Blade Reset or pull out and reconnect the modular connector of the Multiline Termi nal 1 2 Y 65 X XX...

Страница 153: ...wing equipment can be accommodated to the same DLC blade or not de pends on this data When the second data is set to 0 Accommodatable DT300 DT400 Dterm85 PGD 2 U10 ADP Unaccommodatable DESKCON DSS Console When the second data is set to 1 Accommodatable DT300 DT400 Dterm85 DESKCON DSS Console Unaccommodatable PGD 2 U10 ADP NOTE 3 When the second data is set to 0 and accommodating DT300 DT400 Series...

Страница 154: ...r For cross connection of the External Indicator refer to the System Hardware Manual Operating Procedure Main Office 1 The Attendant executes Day Night Mode changeover operation using the normal Attendant Con soles no master method or the master Attendant Console method 2 After a specified time the Day Night Mode at the remote office is changed over Remote Office No manual operation required ...

Страница 155: ...Office A DESCRIPTION DATA Assign the calling party number sent to the net work are not available for the sending number 1 2 Y 12 X XXXXXXXX Station No X XXXX Sending No Assign the Local Office Code Table number 1 2 Y 13 X XXXXXXXX Station No 00 14 Local Office Code Table No 00 14 Assign the Local Office Code sent to the net work is not available for the sending number 1 2 Y 05 00 14 Local Office C...

Страница 156: ...Add the calling party number for Enhanced 911 calls via CCIS route 1 2 Y 5000 5255 LCR Pattern No 000 255 165 Caller ID of outgoing call by CCIS 0 To add Provide the system with Caller ID Display fea ture for CCIS calls 1 2 379 1 To provide Provide each CCH number with Name Display CCIS feature 1 2 Y 26 00 63 CCH No 1 To provide Provide the CCH number with Calling Party Information transferring se...

Страница 157: ...s the pre assigned number calling area code calling station number DESCRIPTION DATA Provide the system with Caller ID Display fea ture for CCIS calls 1 2 379 1 To provide Provide each CCH number with Name Dis play CCIS feature 1 2 Y 26 00 63 CCH No 1 To provide Provide the CCH number with Calling Party Information transferring service 1 2 Y 28 00 63 CCH No 1 To provide Provide the Calling Party In...

Страница 158: ...he original call is placed on hold and receives Music On Hold if provided 3 Dial the second station number and receive ringback tone 4 The second station answers The original call is now on Consultation Hold All Calls CCIS DESCRIPTION DATA Assign Service Restriction Class C to the re quired stations 1 2 Y 07 X XXXXXXXX Station No XX 00 15 Service Restriction Class C Allow the Switch Hook Flash cap...

Страница 159: ... key and receive Feature Dial Tone 2 The original call is placed on hold and receives Music On Hold if provided 3 Dial the second station number and receive ringback tone 4 The second station answers The original call is now on Consultation Hold All Calls CCIS To return to the original call from a Multiline Terminal 1 In any of the following cases the calling station can return to the original cal...

Страница 160: ...S Executive Right of Way and Attendant Override Programming Operating Procedure No manual operation is required DESCRIPTION DATA Assign the function of Analog Data station Single Line Station with FAX or MODEM to required stations 1 2 Y 07 X XXXXXXXX Station No 0 Data station NOTE Ringing interval depends on as follows when the second data is set as 0 The ringing interval for the FAX station is as...

Страница 161: ... Mark Restriction Route Restriction Numbering Restriction Programming DESCRIPTION DATA Assign a Trunk Restriction Class to the re quired stations 1 2 Y 01 Trunk Restriction Class X XXXXXXXX Station No X Z Route Restriction Class X 1 8 Trunk Restriction Class in Day Mode Z 1 8 Trunk Restriction Class in Night Mode 1 Unrestricted RCA 2 Non Restricted 1 RCB 3 Non Restricted 2 RCC 4 Semi Restricted 1 ...

Страница 162: ... Y 051 RCA Y 052 RCB Y 053 RCC Y 054 RCD Y 055 RCE Y 056 RCF Y 057 RCG Y 058 RCH Y 061 RCA Y 062 RCB Y 063 RCC Y 064 RCD Y 065 RCE Y 066 RCF Y 067 RCG Y 068 RCH 00 63 Trunk Route No 0 Restricted 1 Allow To deny access to particular trunk groups from dial repeating Tie trunks specify the combina tion of trunk route restricting the Trunk to Trunk Connection 1 2 Y 0 XX ZZ XX 00 63 Incoming Trunk Tie ...

Страница 163: ...iction Class 7 RCG 27 SV9300 TRK Restriction Class 8 RCH 00 15 2400 IPX TRK Restriction Class 0 15 Assign the SV9300 Trunk Restriction Class to each 2400 IPX Trunk Restriction Class for the restriction class conversion from the 2400 IPX to the SV9300 if required 1 2 30 2400 IPX TRK Restriction Class 0 31 2400 IPX TRK Restriction Class 1 32 2400 IPX TRK Restriction Class 2 33 2400 IPX TRK Restricti...

Страница 164: ...ass 3 04 2400 IPX TRK Restriction Class 4 05 2400 IPX TRK Restriction Class 5 06 2400 IPX TRK Restriction Class 6 07 2400 IPX TRK Restriction Class 7 08 2400 IPX TRK Restriction Class 8 1ST DATA 2ND DATA 30 2400 IPX TRK Restriction Class 0 31 2400 IPX TRK Restriction Class 1 32 2400 IPX TRK Restriction Class 2 33 2400 IPX TRK Restriction Class 3 34 2400 IPX TRK Restriction Class 4 35 2400 IPX TRK ...

Страница 165: ...th the 2400 IPX Tenant number should be assigned as 01 63 not 00 NOTE 2 A reset by CM60 Y 90 0 0 is required after this data setting 1 2 Y 0 3 ATT Group 0 3 assigned by CM60 Y 00 00 63 Tenant No 0 To handle 1 Not handled Assign the access code for LCR Group 3 A129 1 2 Y 0 Number Plan Group 0 3 X XXXX A129 Assign an area code table to be used to select a route pattern table 1 2 Y A000 3 LCR Group 3...

Страница 166: ... 0255 Route Pattern No 000 255 0 Designation of next table 0000 0255 Next Route Pattern No 000 255 Assign the intra office station to the Area Code Development Pattern number assigned by CM8A Y A000 1 2 Y 4005 4007 Area Code Development Pattern No 5 7 X X X Area Code Maximum 8 digits 8001 8008 1 8 digits Intra Office Station Assign the route pattern table with the desired properties and selection ...

Страница 167: ...ttern number assigned by CM8A Y 4005 4007 NOTE This data is required to expand the order of LCR selection that is assigned by CM8A Y 0000 0255 The order of LCR selection can be expand to the maximum seventh 1 2 Y 0000 0255 Route Pattern No 000 255 0 Designation of next table 0000 0255 Next Route Pattern No 000 255 Assign the intra office station to the Area Code Development Pattern number assigned...

Страница 168: ...ENDANT CCIS Operating Procedure To call an Attendant Console 1 The station user dials the operator call code of a master office or a slave office and receives ringback tone 2 The ATND lamp for Incoming Call Identification flashes on the Attendant Console The Attendant answers the call ...

Страница 169: ...e can mask the entered ID code with asterisk on the LCD of Multiline Ter minal to conceal the ID code Programming Operating Procedure No manual operation is required DESCRIPTION DATA Assign Service Restriction Class C to the required stations 1 2 Y 07 X XXXXXXXX Station No XX 00 15 Service Restriction Class C Allow Dial Mask on LCD during talking with trunk in Service Restriction Class C assigned ...

Страница 170: ...0 511 Trunk No 04 Direct In Termination Assign the Abbreviated Code of a station number for the Direct In Termination to originate a call to the destination via CCIS in Day Mode Night Mode Mode A and Mode B respectively 1 2 Y 04 Day Mode Y 05 Night Mode Y 42 Mode A Y 43 Mode B 000 511 Trunk No CXX XX 00 99 Abbreviated Code of Station number for Direct In Termina tion in Day Mode assigned by CM71 6...

Страница 171: ...Allow Assign the Destination Number memory area used exclusively for DIT Outside 1 2 66 Exclusive for DIT Outside XXX YYY XXX 000 299 Starting Memory Slot No in Block YYY 001 300 Number of Slots to be assigned in Block NONE No data Set the stored Destination Number to the Memory Slot number allocated by CM71 1 2 Y 0 000 299 Memory Slot No XXXX YY Y XXXX Access Code Maximum 4 digits Separator Mark ...

Страница 172: ...02 Day Mode Y 03 Night Mode Y 40 Mode A Y 41 Mode B 000 511 Trunk No 04 Direct In Termination Assign the Abbreviated Code of a station number for the Direct In Termination to originate a call to the destination via CCIS in Day Mode Night Mode Mode A and Mode B respectively 1 2 Y 04 Day Mode Y 05 Night Mode Y 42 Mode A Y 43 Mode B 000 511 Trunk No CXX XX 00 99 Abbreviated Code of Station number for...

Страница 173: ...ing Trunk Route ZZ 00 63 Outgoing Trunk Route 0 Allow Assign the Destination Number memory area used exclusively for DIT Outside 1 2 66 Exclusive for DIT Outside XXX YYY XXX 000 299 Starting Memory Slot No in Block YYY 001 300 Number of Slots to be assigned in Block NONE No data Set the stored Destination Number to the Memory Slot number allocated by CM71 1 2 Y 0 000 299 Memory Slot No XXXX YY Y X...

Страница 174: ... between incoming internal and external calls Programming 1 When the ringing cadence on incoming CCIS call by CM35 Y 033 034 is not provided CM08 1209 1 DESCRIPTION DATA Specify the ringing tone interval of Single Line Telephone on incoming calls from station through the CCIS 1 2 Y 00 06 See Interval of Ringing Tones for Single Line Telephone by CM04 Y 00 05 06 07 Page 1 168 RINGING The ringing pa...

Страница 175: ...ond ON 2 seconds OFF For calls from C O Tie Line through CCIS When the CM08 1203 is set to 0 in the opposite office 2 seconds ON 4 seconds OFF When the CM35 Y 000 is set to 04 Tie Line in the opposite office 2 seconds ON 4 seconds OFF 1 second ON 2 seconds OFF When the CM35 Y 000 is set to 00 01 02 03 DDD FX WATS CCSA in the opposite office For calls from C O Tie Line through CCIS When the CM08 12...

Страница 176: ... 392 When the CM08 138 is set to 0 in the opposite office As per CM08 396 For calls from C O Tie Line through CCIS When the CM08 1203 is set to 0 in the opposite office As per CM08 392 When the CM35 Y 000 is set to 04 Tie Line in the opposite office As per CM08 392 As per CM08 396 When the CM35 Y 000 is set to 00 DDD in the opposite office For calls from C O Tie Line through CCIS When the CM08 120...

Страница 177: ...nce on incoming CCIS call by CM35 Y 033 034 1 2 1209 1 Not provided C CM35 Default Y 034 Y 164 0 Y 164 1 0 Ringer Tone Pattern 3 Ringer Tone Pattern 0 1 Ringer Tone Pattern 6 Ringer Tone Pattern 1 2 Ringer Tone Pattern 5 Ringer Tone Pattern 2 3 Ringer Tone Pattern 4 Ringer Tone Pattern 7 CM65 Default Ringer Tone Pattern No Y 40 0 Y 40 1 1 Ringer Tone 1 520 660 Hz 8 Hz Modulating Signal 2 Ringer To...

Страница 178: ...station on incoming calls 1 2 Y 033 00 63 Trunk Route No See the table below North America Only NOTE See Interval of Ringing Tones for Single Line Telephone by CM04 Y 00 05 06 07 Page 1 168 START CM08 CM35 Default CM35 Y 033 2nd Data Ringing Cadence Multiline Terminal Single Line Telephone NOTE 0 0 5 seconds ON 0 5 seconds OFF As per CM04 Y 00 05 1 0 5 seconds ON 0 5 seconds OFF 0 5 seconds ON 1 5...

Страница 179: ... ON 0 25 seconds OFF 0 25 seconds ON 0 25 seconds OFF For EMEA is applied Specify the ringing tone interval of Multiline Terminal to each trunk route 1 2 Y 034 164 00 63 Trunk Route No See the table below A CM35 Default CM35 Y 033 2nd Data Ringing Cadence Multiline Terminal NOTE 1 Single Line Telephone NOTE 2 0 Ringing NOTE 3 As per CM04 Y 00 05 1 Special Ringing As per CM04 Y 00 07 2 Internal Rin...

Страница 180: ...00 63 Tenant No assigned by CM30 Y 01 CM12 Y 04 See the table below B CM65 Default Ringer Tone Pattern No Y 40 0 Y 40 1 1 Ringer Tone 1 520 660 Hz 8 Hz Modulating Signal 2 Ringer Tone 2 660 760 Hz 16 Hz Modulating Signal 3 Ringer Tone 3 1100 Hz Envelop 4 Ringer Tone 4 540 Hz 5 Ringer Tone 5 1100 Hz 6 Not used 1400 1100 Hz 7 Not used 520 660 Hz 16 Hz Modulating Signal END ...

Страница 181: ...al Ringing 1 ON 2 OFF 1 ON 2 OFF 2 ON 4 OFF 2 ON 4 OFF 0 375 ON 0 25 OFF 0 375 ON 2 OFF 0 375 ON 0 25 OFF 0 375 ON 2 OFF 1 ON 4 OFF 0 25 ON 0 25 OFF 0 25 ON 4 25 OFF External Ringing 0 375 ON 0 25 OFF 0 375 ON 2 OFF 2 ON 4 OFF 0 375 ON 0 25 OFF 0 375 ON 2 OFF 2 ON 4 OFF 2 ON 4 OFF 2 ON 4 OFF 0 25 ON 0 25 OFF 0 25 ON 4 25 OFF 1 ON 4 OFF Special Ringing 0 25 ON 0 125 OFF 0 25 ON 0 125 OFF 0 25 ON 2 ...

Страница 182: ...onds ON 5 25 seconds OFF 0 25 seconds ON 0 25 seconds OFF 0 25 seconds ON 5 25 seconds OFF 0 25 seconds ON 0 25 seconds OFF 0 25 seconds ON 5 25 seconds OFF 08 0 375 seconds ON 0 25 seconds OFF 0 375 seconds ON 2 seconds OFF 0 375 seconds ON 0 25 seconds OFF 0 375 seconds ON 2 seconds OFF 0 375 seconds ON 0 25 seconds OFF 0 375 seconds ON 2 seconds OFF 09 0 25 seconds ON 0 125 seconds OFF 0 25 sec...

Страница 183: ...rvice Restriction Class A Allow Do Not Disturb in Service Restriction Class A assigned by CM12 Y 02 1 2 Y 019 00 15 Service Restriction Class A assigned by CM12 Y 02 1 Allow Assign the Do Not Disturb group of stations Do Not Disturb is set simultaneously for the stations assigned by this command by opera tion from the Attendant Console 1 2 Y 00 X XXXXXXXX Station No 0 To provide Assign the access ...

Страница 184: ...nting over Do Not Disturb at receiving an internal incoming call when the Pilot station of a Station Hunting group is set Do Not Dis turb Specify whether to transfer to the destina tion of Call Forwarding Busy Line or of Do Not Disturb by CM51 Y 10 when the station is set Do Not Disturb during setting Call For warding Busy Line 1 2 240 0 To prioritize Station Hunting To the destination of Call For...

Страница 185: ...26 00 15 Service Restriction Class A assigned by CM12 Y 02 1 Allowed Assign Call Forwarding All Calls Outside to the Virtual Line station number assigned by CM11 1 2 Y 00 Call Forwarding All Calls X XXXXXXXX Virtual Line Station No assigned by CM11 Destination No X XXXX YY Y X XXXX Outgoing Trunk 1 4 digits Separate Mark YY Y Called No Maximum 26 dig its NONE No data For system with multiple tenan...

Страница 186: ...the Multiline Terminal DESKCON calls a station set the DND over CCIS 1 2 669 0 To send Do Not Disturb setting 1 To send the restriction Assign the key of Do Not Disturb Override to a Multiline Terminal 1 2 Y 00 My Line Number Key No F1080 Do Not Disturb Override Assign the key of Do Not Disturb Override to a DESKCON 1 2 Y 00 DESKCON No E030 E037 Key No F6108 Do Not Disturb Override START CM08 CM90...

Страница 187: ...T 3 Press the Speaker key To cancel Do Not Disturb CCIS from a Multiline Terminal 1 Press the Speaker key and receive dial tone 2 Press the Do Not Disturb feature key and the associated LED goes out If the Multiline Terminal is equipped with an LCD the display will indicate CNCL 3 Press the Speaker key To operate Do Not Disturb Override CCIS from a Multiline Terminal 1 Lift the handset and receive...

Страница 188: ...To operate Dual Hold CCIS from a Multiline Terminal 1 The user at Station A presses the Hold key the user at Station B is placed on hold 2 The user at Station B presses the Hold key the user at Station A is placed on hold 3 Dual Hold CCIS is now in progress DESCRIPTION DATA Assign Service Restriction Class B to the re quired stations 1 2 Y 02 X XXXXXXXX Station No XX ZZ ZZ 00 15 Service Restrictio...

Страница 189: ...eneral Description This feature allows voice and data station numbers to be assigned to any instrument in the CCIS network based solely on numbering plan limitations PUBLIC NETWORK MAIN OFFICE 4XXXX 51XX 6XXXX 6XXXX 52XX 53XX TRIBUTARY OFFICE PUBLIC NETWORK SATELLITE OFFICE Office location is indicated by all digits of the station number ...

Страница 190: ...m of 6 digits station number should be assigned when providing PMS 1 2 Y 0 3 Numbering Plan Group 0 3 X 1st digit of station No 801 1 digit 802 2 digits 803 3 digits 804 4 digits 805 5 digits 806 6 digits 807 7 digits 808 8 digits Assign a Unit number and Slot number to the LC DLC blade 1 2 Y 0 XX ZZ XX 01 50 Unit No ZZ 01 18 Slot No 10 DLC blade 20 LC blade Assign station number to the required P...

Страница 191: ...o 100 through No 109 Memory Slots 2nd data is 100010 Abbreviated Codes are automatically assigned as shown be low 1 2 65 For Hot Line Outside XXX ZZZ XXX 000 299 Stating Memory Slot No in Block ZZZ 001 300 Number of Slots to be as signed in Block Assign the Called Party number to each Memory Slot number for Hotline 1 2 Y 0 000 299 Memory Slot No XXXX YY Y XXXX Access Code Maximum 4 digits Separato...

Страница 192: ...line to the required sta tions 1 2 Y 03 X XXXXXXXX Station No 09 Delayed Hotline Specify the Delayed Hotline activation timer 1 2 Y 0 119 01 30 1 30 seconds 1 second increment If no data is set the default setting is 10 seconds Define the Delayed Hotline pairs NOTE Do not assign station number with first digit 0 1 2 1 2 Y 00 99 Delayed Hotline Pair No 0 Calling Side X XXXXXXXX Station No 1 Called ...

Страница 193: ... each Memory Slot number for Delayed Hotline 1 2 Y 0 000 299 Memory Slot No XXXX YY Y Called Party No XXXX Access Code Maximum 4 dig its Separator Mark YY Y Called Party No Maximum 26 digits NONE No data 1 2 Y 1 000 299 Memory Slot No XXX X Called Party Name Character Code Maximum 32 digits 16 characters NONE No data See Command Manual 1 2 Y 2 000 299 Memory Slot No XXX X Called Party Name Charact...

Страница 194: ...A 088654 001 Rev 1 0 94ch1005 fm HOT LINE CCIS Operating Procedure To place a Hot Line CCIS call 1 The user at Station A lifts the handset 2 Station B is rung 3 The user at Station B lifts the handset and the connection is established ...

Страница 195: ... 100010 Abbreviated Codes are automatically assigned as shown be low 1 2 65 For Hot Line Outside XXX ZZZ XXX 000 299 Starting Memory Slot No in blocks ZZZ 001 300 No of Memory Slots to be assigned in blocks Assign the Called Party number to each Memory Slot number for Hotline 1 2 Y 0 000 299 Memory Slot No XXXX YY Y XXXX Access Code Maximum 4 digits Separator Mark YY Y Called Party No Maximum 26 d...

Страница 196: ...05 fm HOUSE PHONE CCIS Operating Procedure To call an Attendant in another office 1 The House Phone CCIS user lifts the handset 2 The Attendant in another office is automatically called The ATND lamps on the Attendant Console flash and the console buzzer sounds ...

Страница 197: ...g to be answered at the Attendant Console through the CCIS network Programming DESCRIPTION DATA Specify the ICI key to which an incoming call from each trunk route terminates 1 2 Y 015 00 63 Trunk Route No 75 No 7 CCIS Call Assign the required Attendant Call Selection keys and DESKCON Function keys to each DESKCON according to the Key label 1 2 Y 00 DESKCON No E000 E007 Key No F6000 F6068 Type of ...

Страница 198: ... 94 Release 97 Cancel Talk Position Busy Volume Night 15 01 02 03 04 13 16 17 18 19 20 21 22 14 23 24 26 27 31 32 LDN TIE Busy ATND NANS Recall BV Call Park SC Mute PAGE Start Key No Data Description Key Label 13 14 15 16 17 18 21 24 90 91 93 94 95 96 97 F6000 F6040 F6064 F6060 F6063 F6061 F6150 F6107 F6200 F6201 F6203 F6204 F6202 F6252 F6253 C O Incoming 0 LDN Tie Line Incoming 0 TIE Call Forward...

Страница 199: ...provide Specify the Incoming Call Identification ICI key to which each LDN call from each trunk route will terminate 1 2 Y 015 00 63 Trunk Route No 00 07 C O Incoming Call 0 7 Assign the required number of LDN keys as ICI keys 1 2 Y 00 E00X 13 18 Key No X DESKCON No F6000 F6007 LDN 0 7 Assign the indialed number to each LDN key assigned by CM90 The indialed number should be different from any numb...

Страница 200: ...l is diverted to LDN 0 7 keys as specified by CM58 Y 02 07 even if CM50 Y 01 1 8 has already been set 1 2 Y 01 TAS Group No assigned by CM44 13 Same as CM58 Y 00 00 63 TAS Group No 1 2 Y 02 Day Mode destination of the LDN Same as CM58 Y 00 00 07 LDN key 0 7 08 To TAS 09 To station outside party assigned by CM58 Y 08 1 2 Y 03 Night Mode destination Same as CM58 Y 00 00 07 LDN key 0 7 08 To TAS 09 T...

Страница 201: ...n No CXX Abbreviated Code for Outside Party XX 00 31 Abbreviated Code 1 2 Y 09 Night Mode destination station outside party Same as CM58 Y 00 X XXXXXXXX Station No CXX Abbreviated Code for Outside Party XX 00 31 Abbreviated Code If the 2nd data CXX is designated by CM58 Y 08 09 specify the combination of trunk routes allowing the Tandem connection 1 2 Y 0 XX ZZ XX 00 63 Incoming Trunk Route ZZ 00 ...

Страница 202: ...ION CCIS Operating Procedure No manual operation is required DESCRIPTION DATA Set the stored number to the Memory Slot number allocated by CM71 1 2 Y 0 000 299 Memory Slot No XXXX YY Y XXXX Access Code Maximum 4 digits Separator Mark YY Y Called Party No Maximum 26 digits B CM72 END ...

Страница 203: ...Unit No ZZ 01 18 Slot No 10 DLC blade Assign the station number connected to PGD 2 U10 ADP to its associated Physical Port number 1 2 Y 00 XX YY ZZ Physical Port No XX 01 50 Unit No YY 01 18 Slot No ZZ 01 32 Circuit No X XXXXXXXX Station No Assign the Kind of PGD 2 U10 station NOTE 1 Set the second data to 1 when combining external relay with pag ing Set the second data to 3 only when using this f...

Страница 204: ... PGD 2 U10 ADP set the call history not to be stored when handling an unanswered trunk call 1 2 Y 61 X XXXXXXXX Station No 1 Not stored Allow the accommodation of PGD 2 U10 ADP 1 2 Y 63 X XXXXXXXX Station No 0 To accommodate 1 Not accommodated NOTE 1 Set this data only for a Base Port of DLC blade NOTE 2 Whether the following equipment can be accommodated to the same DLC blade or not de pends on t...

Страница 205: ... Indicator refer to System Hardware Manual Operating Procedure No manual operation is required DESCRIPTION DATA Assign the function of CCIS Link Alarm Indi cation to the PGD 2 U10 ADP 1 2 Y 00 XX Y XX 00 31 Relay Group No Y 0 3 Circuit No 35 XX XX 00 15 CCIS CH No Associate the PGD 2 U10 station number with the Relay Group number 1 2 Y 01 00 31 Relay Group No X XXXXXXXX PGD 2 U10 Station No NONE N...

Страница 206: ...he CCIS link reconnection when a call is connected to the UCD Delay Announce ment for incoming trunk call via CCIS 1 2 607 0 To provide Provide the Link Reconnect Peer to Peer CCIS 1 2 628 1 To provide NOTE The validity of the Link Reconnect CCIS by the combination of CM08 606 607 and 628 is as follows For No 7 CCIS network START CM08 Default CM08 606 CM08 607 To provide Link Reconnect CCIS only 1...

Страница 207: ...IS network A CM08 Default CM08 606 CM08 607 CM08 628 To provide Link Reconnect CCIS only 1 1 1 To provide Link Reconnect CCIS and Link Reconnect CCIS in UCD Delay Announcement for incoming trunk call via CCIS 1 0 1 Not to provide Link Reconnect CCIS and Link Reconnect CCIS in UCD Delay Announcement for incoming trunk call via CCIS 0 Setting invalid Setting invalid END ...

Страница 208: ...e Line Telephone with Message Waiting lamp and a Multiline Terminal LC GCD 4LCF GCD 8LCF blade DESCRIPTION DATA Provide each station with Message Waiting service 1 2 Y 03 X XXXXXXXX Station No 0 To provide NOTE This command is effective only when using a Single Line Telephone with MW lamp Stan dard SIP Terminal Assign Service Restriction Class C to each sta tion 1 2 Y 07 X XXXXXXXX Station No 00 1...

Страница 209: ...Feature Dial Tone 3 Dial the station number and receive Service Set Tone 4 Message Waiting indication is set 5 Press the RELEASE key to return to an idle condition To cancel a Message Waiting indication 1 Press an idle LOOP key and receive dial tone 2 Dial the Message Waiting cancellation code maximum of three digits and receive Feature Dial Tone 3 Dial the station number and receive Service Set T...

Страница 210: ...Telephone with Message Waiting lamp and a Multiline Terminal LC GCD 4LCF GCD 8LCF blade DESCRIPTION DATA Provide each station with Message Waiting service 1 2 Y 03 X XXXXXXXX Station No 0 To provide NOTE This command is effective only when using a Single Line Telephone with MW lamp Stan dard SIP Terminal Assign Service Restriction Class C to each sta tion 1 2 Y 07 X XXXXXXXX Station No 00 15 Servi...

Страница 211: ...mum of three digits and receive Feature Dial Tone 3 Dial the desired station number and receive Service Set Tone 4 Message Waiting indication is set at the station To cancel a Message Waiting indication 1 Lift the handset and receive dial tone 2 Dial the Message Waiting cancellation code maximum of three digits and receive Feature Dial Tone 3 Dial the desired station number and receive Service Set...

Страница 212: ...re provides access to all types of external and customer provided equipment facilities such as Tie Line and exchange network along with Dictation Paging Access CCIS and Code Calling through the CCIS network Programming Refer to Numbering Plan Assignment and assign the trunk access code using the LCR feature Operating Procedure No manual operation is required ...

Страница 213: ...his feature denies certain stations and dial repeating tie trunks access to specific trunk groups such as Tie Line exchange network Dictation or Paging Access CCIS through the CCIS network Programming Assign 1 Restricted as the 2nd Data of CM36 when programming the DELUXE TRAVELING CLASS MARK CCIS Page 1 147 Operating Procedure No manual operation is required ...

Страница 214: ... maximum of 2 Attendant Consoles can be accommodated per DLC blade A maximum of 8 Attendant Consoles can be accommodated in system 1 2 Y 0 XX ZZ XX 01 Unit No ZZ 01 18 Slot No 10 DLC blade Assign the DESKCON No for the appropriate Physical Port number NOTE 1 A blade reset is also required when adding Attendant Consoles to the existing DLC blade NOTE 2 If the PGD 2 U10 ADP is accom modated to the D...

Страница 215: ...ESKCON 1 2 Y 02 Day Mode Y 03 Night Mode Y 40 Mode A Y 41 Mode B 000 511 Trunk No 14 Attendant Console Assign the required Attendant Call Selection keys and Function keys to each DESKCON If no data is set the default setting is as next page 1 2 Y 00 DESKCON No E000 E007 Key No F6000 F6068 Type of Calls to be assigned F6100 F6245 Functions to be assigned A CM30 CM90 B ...

Страница 216: ...ncel Talk Position Busy Volume Night 15 01 02 03 04 13 16 17 18 19 20 21 22 14 23 24 26 27 31 32 LDN TIE Busy ATND NANS Recall BV Call Park SC Mute PAGE Start Key No Data Description Key Label 13 14 15 16 17 18 21 24 90 91 93 94 95 96 97 F6000 F6040 F6064 F6060 F6063 F6061 F6150 F6107 F6200 F6201 F6203 F6204 F6202 F6252 F6253 C O Incoming 0 LDN Tie Line Incoming 0 TIE Call Forwarding Busy Line Bus...

Страница 217: ... 90 0 0 is required after this data setting 1 2 Y 01 0 7 DESKCON No 0 Master ATT 1 Not Master ATT When providing 2nd Ringing feature on the DESKCON make Off Hook Ringing effec tive NOTE A reset by CM60 Y 90 0 0 is required after this data setting 1 2 Y 16 0 7 DESKCON No 0 Effective Allow or restrict the system to keep the volume level changed by the volume button on DESKCON after the call is finis...

Страница 218: ...d data 16 cannot be displayed on DESKCON LCD 1 2 Y 00 00 00 Japanese 01 English 02 French Canadian French 03 Spanish Latin Spanish 04 Portuguese Brazilian Portuguese 05 German 06 Italian 07 Netherlandish 08 French Europe 09 Spanish Europe 10 Portuguese Europe 11 Swedish 12 Danish 13 Catalan 15 Russian 16 Turkish 31 English Make the LCD display settings to be applied to each Multiline Terminal in t...

Страница 219: ...e Night mode has been entered Programming Refer to DIRECT IN TERMINATION CCIS Page 1 156 Operating Procedure To answer a Night Connection Fixed CCIS call 1 An incoming call to the Attendant Console in Night mode is automatically transferred to a prese lected Night Connection station belonging to a different office 2 The calling party hears ring back tone 3 Ring signal is sent to the Night Connecti...

Страница 220: ...ng Procedure To set the Night Connection Flexible CCIS 1 The Attendant or fixed night station user in the destination office sets Call Forwarding All Calls CCIS to a station in another office To answer Night Connection Flexible CCIS calls 1 In the Night mode incoming calls to the Attendant Console are automatically transferred to a pre selected Night Connection station belonging to a different off...

Страница 221: ...e remote PBX Programming DESCRIPTION DATA Assign Service Restriction Class A to the re quired stations 1 2 Y 02 X XXXXXXXX Station No XX ZZ XX 00 15 Service Restriction Class A Allow Outgoing Trunk Queuing in Service Re striction Class A assigned by CM12 Y 02 1 2 Y 002 00 15 Service Restriction Class A as signed by CM12 Y 02 1 Allow Assign access code for setting and resetting this service 1 2 Y 0...

Страница 222: ...ss code and receive dial tone 2 Dial the desired number and receive busy tone 3 Press the hookswitch momentarily and receive Feature Dial Tone 4 Dial the Outgoing Trunk Queuing CCIS feature access code and receive Service Set Tone 5 Replace the handset To cancel Outgoing Trunk Queuing CCIS 1 Dial the Outgoing Trunk Queuing CCIS cancellation code and receive Service Set Tone ...

Страница 223: ...XX 01 50 Unit No ZZ 01 18 Slot No 10 DLC blade Assign the station number connected to PGD 2 U10 ADP to its associated Physical Port number 1 2 Y 00 XX YY ZZ Physical Port No XX 01 50 Unit No YY 01 18 Slot No ZZ 01 16 Circuit No FX FXXXXXXXX Station No For the station connected to PGD 2 U10 ADP set the Message Waiting Stored Call Record lamps not to be lit 1 2 Y 03 X XXXXXXXX Station No 1 Not provi...

Страница 224: ...ated to the same DLC blade or not depends on this data When the second data is set to 0 Accommodatable DT300 DT400 Dterm 85 PGD 2 U10 ADP Unaccommodatable DESKCON DSS Console When the second data is set to 1 Accommodatable DT300 DT400 Dterm 85 DESKCON DSS Console Unaccommodatable PGD 2 U10 ADP NOTE 3 When the second data is set to 0 and accommodating DT300 DT400 Series DESI less to the same DLC bl...

Страница 225: ...No assigned by CM20 Y 0 3 A070 A079 NONE No data Specify whether the SST is sent to a paging station PGD 2 U10 when a speaker paging is seized 1 2 732 0 To send 1 Not sent Specify whether to provide the Paging Answer by PGD 2 U10 Station Dialing only in the case of Delay and Non delay answer NOTE The Paging Answer by the following methods is applied depending on the setting of this command When th...

Страница 226: ...o NONE No data Assign Service Restriction Class A for Paging Access to the required stations 1 2 Y 02 X XXXXXXXX Station No XX ZZ XX 00 15 Service Restriction Class A Allow Paging Access in Service Restriction Class A assigned by CM12 Y 02 1 2 Y 08 00 15 Service Restriction Class A as signed by CM12 Y 02 1 Allow Assign the forced release timer when the Pag ing Trunk is not released after seizing t...

Страница 227: ...lamps not to be lit 1 2 Y 03 X XXXXXXXX Station No 1 Not provided For the station connected to PGD 2 U10 ADP set the call history not to be stored when answering a station call 1 2 Y 41 X XXXXXXXX Station No 1 Not stored For the station connected to PGD 2 U10 ADP set the call history not to be stored when handling an unanswered station call 1 2 Y 49 X XXXXXXXX Station No 1 Not stored For the stati...

Страница 228: ...079 NONE No data Assign the access code for Paging Answer 1 2 Y 0 3 Numbering Plan Group 0 3 X XXXX Access Code A070 A079 For Paging Answer Zone 0 9 Assign the paging function to the PGD 2 U10 ADP 1 2 Y 00 XX Y XX 00 31 Relay Group No Y 0 3 Circuit No of PGD 2 U10 ADP 02XX Speaker Paging Start XX 00 09 Speaker Paging Zone 0 9 Associate the PGD 2 U10 station number with the Relay Group number 1 2 Y...

Страница 229: ...006 fm PAGING ACCESS CCIS DESCRIPTION DATA Assign the station connected to Dual port mode of the PGD 2 U10 ADP CH2 1 2 Y 34 X XXXXXXXX Station No 0 Station connected to Dual port mode of the PGD 2 U10 ADP 1 Station not connected to the PGD 2 U10 ADP B CM13 END ...

Страница 230: ...13 49 350 1 Set the call history not to be stored when handling an unanswered station call 13 60 350 1 Set the call history not to be stored when answering a trunk call 13 61 350 1 Set the call history not to be stored when handling an unanswered trunk call 13 63 350 0 Allow the accommodation of PGD 2 U10 ADP NOTE Set this data only for a Base Port of DLC blade 12 65 350 1 Assign the kind of PGD 2...

Страница 231: ...ay answer or Non delay and delay answer 08 157 0 1 Specify whether provide the Paging Answer by dialing PGD 2 U10 station number 20 0 3 803 Assign the Access Code for Paging NOTE This Access Code is used for Paging Paging Answer when providing the Paging Answer with PGD 2 U10 station number CM08 157 0 20 0 XX NOTE 2 A070 Assign the Access Code for Paging Answer Paging Zone 0 NOTE 1 Assign this dat...

Страница 232: ...g a station call 13 49 350 1 Set the call history not to be stored when handling an unanswered station call 13 60 350 1 Set the call history not to be stored when answering a trunk call 13 61 350 1 Set the call history not to be stored when handling an unanswered trunk call 13 63 350 0 Allow the accommodation of PGD 2 U10 ADP NOTE Set this data only for a Base Port of DLC blade 12 65 350 1 Assign ...

Страница 233: ... Non delay and delay answer 08 157 0 1 Specify whether provide the Paging Answer by dialing PGD 2 U10 station number 20 0 3 803 Assign the Access Code for Paging NOTE This Access Code is used for Paging Paging Answer when providing the Paging Answer with PGD 2 U10 station number CM08 157 0 20 0 XX NOTE 2 A070 Assign the Access Code for Paging Answer Paging Zone 0 NOTE 1 Assign this data when not p...

Страница 234: ...ll history not to be stored when handling an unanswered trunk call 12 65 370 1 Assign the kind of PGD 2 U10 station CH2 to Paging 12 68 370 01 Assign the Paging Zone No to 01 44 00 011 0201 Assign the Speaker Paging Zone 1 44 01 01 370 Assign the PGD 2 U10 station number to Relay Group number 13 32 350 0 Provide the connection with dual port mode to the PGD 2 U10 station number CH1 13 33 350 0 Ass...

Страница 235: ... connection to paging equipment is established CM Y No 1 ST DATA 2ND DATA REMARKS When using the Paging Answer 12 67 370 1 2 Assign the kind of paging to Non delay answer or Non delay and delay answer 20 0 3 803 Assign the Access Code for Paging NOTE This Access Code is used for Paging Paging Answer when providing the Paging Answer with PGD 2 U10 station number CM08 157 0 20 0 XX NOTE 2 A071 Assig...

Страница 236: ...G CALLS CCIS General Description This feature automatically restricts users of preselected stations from placing outgoing calls and or certain miscellaneous trunk calls through CCIS without Attendant assistance Programming Refer to DELUXE TRAVELING CLASS MARK CCIS Page 1 147 Operating Procedure No manual operation is required ...

Страница 237: ... 1 0 94ch1006 fm SINGLE DIGIT STATION CALLING CCIS SINGLE DIGIT STATION CALLING CCIS General Description This feature allows the assignment of Single Digit Station numbers Programming DIAL X SATELLITE OFFICE MAIN OFFICE PBX PBX NO 7 CCIS STATION NO X ...

Страница 238: ...No 5 7 Assign the same digit which was assigned as the access code in CM20 into the selected area code table 1 2 Y 4005 4007 X XXXX Access Code 0000 0255 Route Pattern No 000 255 Assign the next Route Pattern number to the Route Pattern number assigned CM8A Y 4005 4007 NOTE This data is required to expand the order of LCR selection that is as signed by CM8A Y 0000 0255 The order of LCR selection c...

Страница 239: ...he LC DLC blade 1 2 Y 0 XX ZZ XX 01 50 Unit No ZZ 01 18 Slot No 10 DLC blade 20 LC blade Assign a station number to each Physical Port number NOTE To the following stations 5 or more digits station number must not be assigned Stations observed by SMDR PMS OAI Front Desk Terminal Digital Multiline Terminal TIMS CIS 1 2 Y 00 XX YY ZZ Physical Port No XX 01 50 Unit No YY 01 18 Slot No ZZ 01 32 Circui...

Страница 240: ...IS FEATURES 1 226 NWA 088654 001 Rev 1 0 94ch1006 fm STATION TO STATION CALLING CCIS Operating Procedure To place a Station to Station call 1 Lift the handset and receive dial tone 2 Dial the desired station number ...

Страница 241: ...eature for an outgoing call by System Speed Dialing Station Speed Dialing if desired 1 2 035 Station Speed Dialing 0 Not provided 1 To provide 1 2 044 System Speed Dialing 0 Not provided 1 To provide Provide the system with Toll Diversion or Toll Denial 1 2 119 0 Toll Diversion Routed to ICPT key on DESKCON 1 Toll Denial Routed to Reorder Tone Assign a Trunk Restriction Class to each sta tion 1 2 ...

Страница 242: ...signed by CM35 Y 097 Toll Restriction Pattern 00 15 have already been programmed as shown be low If a new Restriction Pattern is required change the data for Restriction Patterns 01 13 00 14 and 15 are fixed 1 2 Y 01 13 Toll Restriction Pattern No 01 13 1 8 Trunk Restriction Class 0 Restricted 3 Allowed A CM35 CM81 0 Restricted 3 Allowed TRUNK RESTRICTION CLASS Y 01 02 03 04 05 06 07 08 09 10 11 1...

Страница 243: ...Code Development Pattern number assigned by CM35 Y 076 For exam ple to provide the Trunk Restriction Class RCB RCC RCD RCE RCF RCG and RCH with the Toll Restriction for Area Code 00 Area Code 00 Toll Restriction Pattern 05 See Toll Restriction Pattern Table on CM81 If the Toll Restriction Pattern for the same area code is changed according to the Tenant Date and Time add the required patterns Tena...

Страница 244: ...1 2 Y 0000 0255 Route Pattern No 000 255 1 XXX 00 XXX 000 255 TR Pattern No STEP 4 Assign a Toll Restriction Pattern number assigned by CM81 to the TR Pattern number assigned by Step 3 1 2 Y 5000 5255 TR Pattern No 000 255 000 00 15 Toll Restriction Pattern No 00 15 To add the Time and Data Pattern STEP 1 Assign an area code to be restricted and a Date Pattern number to the Area Code Development P...

Страница 245: ...y one 0700 7 00 AM 7 30 AM 0730 7 30 AM 8 00 AM 0800 8 00 AM 8 30 AM 2030 8 30 PM 9 00 PM 1 2 Y 2000 2007 Time Pattern No 0 7 XX ZZ Starting Time XX 00 23 Hours ZZ 00 30 Minutes 0000 0255 Route Pattern No 000 255 If Tenant Pattern is required set 1000 1015 Tenant Pattern No 0 15 STEP 4 Assign a TR Pattern number to the Route Pattern number assigned by Step 3 1 2 Y 0000 0255 Route Pattern No 000 25...

Страница 246: ...in Night mode When this feature is activated incoming exchange network calls will activate a common alert Trunk An swer from Any Station TAS signal at the customer premises By dialing a specified code any station may answer the call and extend it to any other station through the CCIS network using Call Transfer All Calls CCIS Programming SATELLITE OFFICE TAS NO 7CCIS MAIN OFFICE COT DID CO PBX PBX...

Страница 247: ...ass B to the re quired stations 1 2 Y 02 X XXXXXXXX Station No XX ZZ ZZ 00 15 Service Restriction Class B Allow Trunk Answer From Any Station TAS in Service Restriction Class B assigned by CM12 Y 02 1 2 Y 053 00 15 Service Restriction Class B as signed by CM12 Y 02 1 Allow Provide the system with the Diversion Display and the LDN Diversion features 1 2 204 Diversion Display 0 To provide 1 2 205 LD...

Страница 248: ...Destination Same as CM58 Y 00 08 To TAS Specify the function of each type of TAS with in a system 1 2 Y 0 4 TAS Answer A E 1 Tie Line DID 0 Cannot be answered 1 Can be answered 1 2 7 A call terminated to a different tenant 0 Can be answered 1 Cannot be answered Assign the access code for each type of TAS TAS Answer A E assigned by CM53 1 2 Y 0 3 Numbering Plan Group 0 3 X XXXX Access Code A047 TAS...

Страница 249: ...01 Rev 1 0 94ch1006 fm TRUNK ANSWER FROM ANY STATION CCIS DESCRIPTION DATA Specify the tenants allowing TAS Answer be tween them 1 2 Y 0 XX ZZ XX 00 63 Tenant No of TAS Answer station ZZ 00 63 Tenant No of Trunk 0 Allow 1 Restricted B CM63 END ...

Страница 250: ... 1 2 Y 13 Day Mode 14 Night Mode 000 511 Trunk No 01 TAS BUZZER Assign the TAS Group number assigned by CM30 Y 17 to a circuit number of the Exter nal Relay Interface on CPU 1 2 Y 00 312 313 External Relay Interface on CPU 13 XX XX 00 63 TAS Group No assigned by CM30 Y 17 Specify the indication pattern for the External TAS Indicator 1 2 00 01 30 IPM 02 60 IPM 03 120 IPM 07 Steady on NONE 120 IPM 0...

Страница 251: ... ZZ 01 18 Slot No 10 DLC blade Assign the station number connected to PGD 2 U10 ADP to its associated Physical Port number 1 2 Y 00 XX YY ZZ Physical Port No XX 01 50 Unit No YY 01 18 Slot No ZZ 01 32 Circuit No X XXXXXXXX Station No Assign the Kind of PGD 2 U10 station NOTE 1 Set the second data to 1 when combining external relay with pag ing Set the second data to 3 only when using this feature ...

Страница 252: ...ed to PGD 2 U10 ADP set the call history not to be stored when handling an unanswered trunk call 1 2 Y 61 X XXXXXXXX Station No 1 Not stored Allow the accommodation of PGD 2 U10 ADP 1 2 Y 63 X XXXXXXXX Station No 0 To accommodate 1 Not accommodated NOTE 1 Set this data only for a Base Port of DLC blade NOTE 2 Whether the following equipment can be accommodated to the same DLC blade or not de pends...

Страница 253: ... 00 XX Y Circuit No XX 00 31 Relay Group No Y 0 3 Circuit No 13 XX XX 00 63 TAS Group No assigned by CM30 Y 17 Associate the PGD 2 U10 station number with the Relay Group number 1 2 Y 01 00 31 Relay Group No X XXXXXXXX PGD 2 U10 Station No NONE No data Specify the indication pattern for the External TAS Indicator 1 2 00 01 30 IPM 02 60 IPM 03 120 IPM 07 Steady on NONE 120 IPM 0 25 seconds ON OFF B...

Страница 254: ...bering Plan Assignment Pattern 2 When an incoming LDN call is diverted to a Satellite Office in either Day Mode or Night Mode not both the following programming for the LDN Diversion Outside feature is required DESCRIPTION DATA Provide the system with the Diversion Display and the LDN Diversion features 1 2 204 Diversion Display 0 To provide 1 2 205 LDN Diversion 0 To provide Assign the indialed n...

Страница 255: ...m Speed Dialing Assigned by CM71 66 Assign the System Speed Dialing memory area exclusively for LDN Diversion Outside 1 2 66 Exclusive for LDN Diversion Outside XXX YYY XXX 000 299 Starting Memory Slot No in Block YYY 001 300 Number of Slots to be as signed in Block NONE No data Set the stored number into the Memory Slot number allocated by CM71 1 2 000 299 Memory Slot No XXXX YY Y XXXX Access Cod...

Страница 256: ... Type Visual and or Audible type with volume control For cross connection of the TAS indicator refer to the System Hardware Manual To provide the telephone set for TAS Indication GCD 4LCF GCD 8LCF blade Two telephone sets per blade can be equipped Conventional telephone sets Operating Procedure To answer an incoming call in Night mode 1 The TAS signal bell buzzer etc sounds indicate an incoming ca...

Страница 257: ...onnection at the following office can be restricted by Trunk Restriction Class of Trunk A and Outgoing Connection Restriction data of Trunk B Case 2 When Station B transfers an Incoming Call through CCIS to Trunk C a Trunk to Trunk con nection can be restricted by Trunk Restriction Class of Trunk A and Outgoing Connection Re striction data of Trunk C INCOMING TRUNK Trunk A Office B Office A OUTGOI...

Страница 258: ...Y 097 00 63 Route No X Z X 1 8 Day Class Z 1 8 Night Class 1 Unrestricted RCA 2 Non Restricted 1 RCB 3 Non Restricted 2 RCC 4 Semi Restricted 1 RCE 5 Semi Restricted 2 RCE 6 Restricted 1 RCF 7 Restricted 2 RCG 8 Fully Restricted RCH Assign the Area Code Development Pattern number to the required trunk route 1 2 Y 076 00 63 Trunk Route No 00 07 Area Code Development Pattern No 0 7 START CM35 A ...

Страница 259: ...ty The maximum number of sending digits including the area codes should be assigned to each area code 1 2 Y 0 7 Area Code Development Pattern No 0 7 assigned by CM8A Y A000 X X X Area Code dialed Maximum 8 digits 01 24 1 24 digits 25 79 25 79 digits A CM81 0 Restricted 3 Allowed TRUNK RESTRICTION CLASS Y 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 00 TOLL RESTRICTION PATTERN NUMBER ON EACH TRUNK ...

Страница 260: ...Restriction for Area Code 00 Area Code 00 Toll Restriction Pattern 05 See Toll Restriction Pattern Table on CM81 1 2 Y 4000 4004 Area Code Development No 0 4 X X X Area Code Maximum 8 digits B000 B015 Toll Restriction Pattern 00 15 If the Toll Restriction Pattern for the same area code is changed according to the Tenant Date and Time add the required patterns Tenant Date and Time to the area code ...

Страница 261: ...5 Route Pattern No 000 255 1 XXX 00 XXX 000 255 TR Pattern No 000 255 STEP 4 Assign the Toll Restriction Pattern number assigned by CM81 to TR Pattern number assigned by Step 3 1 2 Y 5000 5255 TR Pattern No 000 255 000 00 15 Toll Restriction Pattern No 00 15 To add the Time and Date Pattern STEP 1 Assign the area code to be restrict ed and the Date Pattern number to the Area Code Development Pat t...

Страница 262: ...730 7 30 AM 8 00 AM 0800 8 00 AM 8 30 AM 2030 8 30 PM 9 00 PM 1 2 Y 2000 2007 Time Pattern No 00 07 XX ZZ Starting Time XX 00 23 Hours ZZ 00 30 Minutes 0000 0255 Route Pattern No 000 255 If Tenant Pattern is required set 1000 1015 Tenant Pattern No 00 15 STEP 4 Assign the TR Pattern number to the Route Pattern number assigned by Step 3 1 2 Y 0000 0255 Route Pattern No 000 255 1 XXX 00 XXX 000 255 ...

Страница 263: ...ass 7 RCG 27 SV9300 TRK Restriction Class 8 RCH 00 15 2400 IPX TRK Restriction Class 0 15 Assign the SV9300 Trunk Restriction Class to each 2400 IPX Trunk Restriction Class for the restriction class conversion from 2400 IPX to SV9300 if required 1 2 30 2400 IPX TRK Restriction Class 0 31 2400 IPX TRK Restriction Class 1 32 2400 IPX TRK Restriction Class 2 33 2400 IPX TRK Restriction Class 3 34 240...

Страница 264: ... Class 3 04 2400 IPX TRK Restriction Class 4 05 2400 IPX TRK Restriction Class 5 06 2400 IPX TRK Restriction Class 6 07 2400 IPX TRK Restriction Class 7 08 2400 IPX TRK Restriction Class 8 1ST DATA 2ND DATA 30 2400 IPX TRK Restriction Class 0 31 2400 IPX TRK Restriction Class 1 32 2400 IPX TRK Restriction Class 2 33 2400 IPX TRK Restriction Class 3 34 2400 IPX TRK Restriction Class 4 35 2400 IPX T...

Страница 265: ...two to eight Programming In addition to the programming of Numbering Plan Assignment to assign the Own Office number for 5 digits do the following programming Operating Procedure To call a station located in another office by using Numbering Plan 1 1 Lift the handset and receive dial tone 2 Dial any digit station number from three to eight digits 3 The call is routed to another office according to...

Страница 266: ...sing Numbering Plan 2 1 Lift the handset and receive dial tone 2 Dial the access code for CCIS 3 Dial the one two or three digit office code and any digit station number from two to eight digits 4 The call is routed to the office designated by the office code The called station rings 5 The called station answers and the parties are connected ...

Страница 267: ...ating Procedure From a Multiline Terminal to another Multiline Terminal 1 The originating Multiline Terminal user dials the desired station number in another office and re ceives ring back tone 2 The calling party presses the Voice Call feature key A signal tone is transmitted over the CCIS network to the called party s speaker The calling party s LCD shows 3 The called party presses the MIC key i...

Страница 268: ...CI Programming Refer to Programming Manual Operating Procedure To record a message into the VMS 1 Lift the handset and receive dial tone 2 Dial the voice mail station number and receive ringback tone 3 Follow the instructions given by the VMS To retrieve a message from the VMS 1 Lift the handset and receive dial tone 2 Dial the voice mail station number and receive ringback tone The LCD shows xxx ...

Страница 269: ... handset and receive dial tone 2 Dial the Call Forwarding or Split Call Forwarding feature access code and receive Special Dial Tone 3 Dial the voice mail station number and receive Service Set Tone The LCD shows SET xxxx VMS Voice mail station number To call a station number whose call forwarding is set to the VMS 1 Lift the handset and receive dial tone 2 Dial the desired station number and rece...

Страница 270: ...for Voice Mail Live Record CCIS to a Multiline Terminal 1 2 Y 00 My Line Number Key No F5026 Record F5027 End F5028 Play Specify the use of Record key assigned by CM90 Y 00 F5026 for Voice Mail Live Re cord CCIS 1 2 578 0 Used as Record key and End key 1 Used as Record key Specify the Mail Box number to hear a mes sage when the Play key for Voice Mail Live Record CCIS is pressed while seizing a Su...

Страница 271: ...usive for Voice mail station No XXX YYY XXX 000 299 Starting Memory Slot No in Block YYY 001 099 Number of Memory Slots to be assigned in Block Assign the Voice mail station number to the memory slot number in slot allocated by CM71 NOTE If the Voice mail station number is set in open numbering system you should set Access Code Area Code of the Voice mail station the Voice mail station number 1 2 ...

Страница 272: ... Specify whether a Live Record start signal that includes caller information such as station number and a kind of calling party is sent to the VMS 1 2 702 0 To send 1 Not sent Specify whether a release signal is sent to the VMS when a station trunk hangs up while ac cessing the VMS 1 2 704 0 To send 1 Not sent Specify whether MW lamp control on a station of an opposite office from the VMS via CCIS...

Страница 273: ...NOTE 1 While recording the operations such as hooking holding is not available at both sides NOTE 2 Though the opposite side releases the line the recording continues as long as the recording side doesn t stop recording To play a record from the VMS There are two ways to play it One way is the same as VOICE MAIL INTEGRATION CCIS See that of Operating Procedure Page 1 254 The other way is as follow...

Страница 274: ...ming For VMS office DESCRIPTION DATA Assign Service Restriction Class A to the VMS stations NOTE 1 This Service Restriction Class set to the VMS station is sent to the calling office when the VMS answers the call via CCIS The calling office judges the called party as the VMS by the Service Re striction Class sent from the VMS office NOTE 2 VMS pilot and ports must be in a dif ferent Service Restri...

Страница 275: ...Voice Mail System DESCRIPTION DATA Allow Voice Mail Private Password CCIS to Service Restriction Class A of the VMS on the opposite office NOTE CM15 Y 147 is not effective for the Service Restriction Class of own office 1 2 Y 147 00 15 Service Restriction Class A 0 Allow Allow Voice Mail Private Password to each tenant 1 2 Y 30 00 63 Tenant No 0 Allow START CM15 CM65 END ...

Страница 276: ...1 262 NWA 088654 001 Rev 1 0 94ch1006 fm THIS PAGE LEFT BLANK INTENTIONALLY ...

Страница 277: ...Rev 1 0 94ch2001 fm UNIVERGE SV9300 Networking Manual Chapter 2 Q SIG FEATURES This chapter explains the system outline system configuration sys tem conditions available services and programming procedure for Q SIG system ...

Страница 278: ...s Inter exchange signaling protocol for circuit mode basic services by European Telecommuni cation Standards Institute ETSI The Q SIG protocol creates Layer 3 messages between Q reference points expected as conceptual point for inter office signalling System Outline of Q SIG NOTE Conforming to Q921 a PBX PBX Interface PBX PRT Data Link Layer Physical Layer Call Control Protocol Control Q PBX DTI D...

Страница 279: ...f 23 B channels Physical Interface of 24PRT Physical Interface of 30PRT On the Q SIG system with 30PRT a 2 Mbps primary rate interface is used for the interface trunk The PRT provides a built in D channel handler A single data link channel can control a maximum of 30 B channels Physical Interface of 30PRT Physical Interface D channel B channel PRT PBX PRT Physical Interface Maximum 23B D Maximum 2...

Страница 280: ... Other Network The PBX can be connected with the other manufacturer s PBX by the Q SIG interface and the Q SIG network can interwork with the other network Interworking with Other Network SV9300 ISDN Q SIG Network ACIS Existing Office Existing Office CCIS Q SIG interface Other Manufacturer Network ...

Страница 281: ...RATION The following figure shows the system configuration of the Q SIG system System Configuration of Q SIG 1 5M 2M PCM DIGITAL LINE 23B 30B D CLOCK SIGNAL PBX 23B 30B SLT CPU PRT 24 30 Channel Primary Rate Interface PLO Phase Locked Oscillator D TDSW PRT LC NETWORK Multiline Terminal DLC Q SIG PLO ...

Страница 282: ... Unipolar Bipolar Conversion AMI B8ZS Format Alarm Detection Insertion Loopback Test Local Loopback Cyclic Redundancy Checking based on ITU T Rec G704 For 30PRT Unipolar Bipolar Conversion HDB3 Format Alarm Detection Insertion Loopback Test Local Loopback Cyclic Redundancy Checking based on ITU T Rec G704 For connection of a 24PRT and transmission line twisted pair cable can be used For connection...

Страница 283: ...k routes are available one is the route 0 to receive clock signals from PRT0 and the other is a standby route 1 PRT1 to receive clock signals when no clock signals appear on the route 0 When no clock signals come from either route 0 or route 1 the PLO keeps generating the clock signals at the frequency of the last source clock The PLO can receive different frequency of source clocks from the route...

Страница 284: ...e the system also allocates time slots to channels not assigned For example as shown below even when Channel 1 through Channel 10 have been assigned by the system data programming CM10 Y 00 excepting Channel 5 the system allocates a total of 10 time slots for all the ten channels Therefore to avoid allocation of unnecessary time slots it is recommended that consec utive channels are assigned on ea...

Страница 285: ...LCD of calling party and the calling party number name sent from the opposite office can be indicated on the LCD of called party Also if you do not need the indications above mentioned restriction of them to each station is possible Connected Destination Indication Calling Party Information Indication STATION No 200 USER S NAME KEN OFFICE 10 Q SIG NETWORK STATION No 300 USER S NAME JOHN OFFICE 20 ...

Страница 286: ... is an ISDN telephone or a terminal which has no indicator the station number user s name cannot be indicated There are following conditions for Attendant Console in this feature If the station number exceeds 6 digits the last 6 digits are indicated on the LCD Attendant Console number cannot be sent Attendant Console user s name cannot be sent received It can be specified to each station Single li...

Страница 287: ... state of consultation hold call transfer the called station user s name is sent to the calling station If the called station is in the state of call holding the station user s name is not sent Since a user s name of calling station is sent to the opposite office if the called station provides the Call Forwarding All Calls feature the calling user s name is indicated on the LCD of terminated sta t...

Страница 288: ...om mand is set to NONE No data the PRT blade for ISDN data communi cation must be accommodated to the base slot Slot No 01 07 13 of each line trunk module In this case the available Highway Channels for data communication are the only first 16 channels NOTE 2 When this command is set additional chassis time slots are used Example CM05 Y 2 0101 12 will use 12 chassis time slots 1 2 Y 2 XX ZZ XX 01 ...

Страница 289: ...nk No Assign the destination to receive the synchro nous signal for PRT 1 2 Y 10 59 01 First priority 02 Second priority 01 18 Slot No NOTE 1 This data is assigned for the clock synchronization of SV9300 for the opposite office of ISDN network CCIS Digital Tie Line Do not assign this data for ISDN terminals NOTE 2 The second data must be assigned the Slot number to which each interface blade PRT B...

Страница 290: ... Mode Y 03 Night Mode 000 511 Trunk No assigned by CM10 Y 00 31 Handling of busy Assign the trunk route data to the B channel trunk route number assigned by CM30 Y 00 NOTE CM35 Y 000 004 005 009 and 020 should be assigned to only the B channel trunk routes For D channel trunk route no data setting is required 1 2 Y 000 Kind of Trunk Route 00 63 B channel Trunk Route No 04 Tie Line trunk 1 2 Y 004 ...

Страница 291: ...annel trunk route 1 2 Y 091 00 63 B channel Trunk Route No 00 63 CCH No 1 2 Y 091 00 63 D channel Trunk Route No 00 63 CCH No Assign the D channel number to the B channel trunk routes 1 2 Y 093 00 63 B channel Trunk Route No 00 31 D channel No Assign the LAPD mode of the D channel trunk route This data setting must not be identical with the opposite PBX If the opposite PBX is defined as a Network ...

Страница 292: ...n Signaling Channel NOTE 2 This command must be assigned after CM35 Y 090 and CM35 Y 091 are assigned 1 2 Y 35 000 511 Trunk No 001 127 CIC Assign the trunk number to be used as the com mon signaling channel 1 2 Y 00 00 63 CCH No 000 511 Trunk No assigned by CM10 Y 00 Assign an Originating Point Code OPC to each CCH number NOTE The Originating Point Code OPC is used to designate an originating off...

Страница 293: ...el path between PRT 1 2 Y 00 00 31 D channel No 000 511 Trunk No assigned by CM10 Y 00 Specify the function of Analog Data station Single Line Station with FAX or MODEM 1 2 Y 07 X XXXXXXXX Station No 0 Data station 3 1 kHz audio 1 Ordinary station voice NOTE 1 This command is used to specify the information transfer capability of bearer capability NOTE 2 When the second data is set to 0 3 1 kHz au...

Страница 294: ...k PRT ON 1 2 Y 22 Loopback setting 000 127 Trunk Blade No assigned by CM05 Y 1 1 Remote Loop Back for PRT FIFO unavailable 2 Payload Loop Back for PRT maintenance bit unavailable 3 Remote Loop Back for PRT FIFO available 4 Payload Loop Back for PRT maintenance bit available 7 Loop Back OFF for PRT DESCRIPTION DATA Reassign Highway Channel 1 2 Y 9 XX YY XX 01 50 Unit No YY 01 07 13 Lowest Slot No w...

Страница 295: ...XXXXXX Station No XX ZZ XX 00 15 Service Restriction Class A ZZ 00 15 Service Restriction Class B Allow or Restrict Connected Destination Number Indication Calling Party Number In dication in Service Restriction Class B as signed by CM12 Y 02 1 2 Y 151 00 15 Service Restriction Class B assigned by CM12 Y 02 0 Restricted 1 Allow Allow Calling Number Display for incoming calls in Service Restriction...

Страница 296: ... No assigned by CM12 Y 12 1 4 digits ISDN Local Office Code assigned by CM50 Y 05 1 12 digits This number must be in the indial range assigned by Telecom for the ISDN line For example National Destination Code for Dallas 214 Local Code for a station 518 5000 In this case the ISDN Number is National Destination Code Local Code 214518 5000 That is ISDN Subscribers No assigned by CM12 Y 12 is 5000 IS...

Страница 297: ...ection priority for the Route Pattern number assigned by CM8A Y 4005 4007 1 2 Y 0000 0255 Route Pattern No 000 255 1 1st priority 2 2nd priority 3 3rd priority 4 4th priority XXX ZZ XXX 000 255 LCR Pattern No ZZ 00 63 Trunk Route No Add the Calling Party Number for ISDN calls via CCIS Q SIG route 1 2 Y 5000 5255 LCR Pattern No 000 255 165 Caller ID of outgoing call by CCIS Q SIG 0 To add Provide t...

Страница 298: ...triction Class B Allow or Restrict Connected Destination Name Indication Calling Party Name Indica tion in Service Restriction Class B assigned by CM12 Y 02 1 2 Y 152 00 15 Service Restriction Class B assigned by CM12 Y 02 0 Restricted 1 Allow Allow Calling Name Display for incoming calls in Service Restriction Class A assigned by CM12 Y 02 1 2 Y 136 00 15 Service Restriction Class A assigned by C...

Страница 299: ...or the calling party user s name setting use A Z capital 0 9 or spaces NOTE 2 There are two ways to change a name that currently programmed By overwriting with a new name or by inserting a blank space as the first character will cancel existing name 1 2 Y 0 By Character Code X XXXXXXXX Station No Character Code 20 7F Maximum 32 digits See CM77 in the Command Manual 1 2 Y 1 By Character X XXXXXXXX ...

Страница 300: ... be dialed in the Area Code Development Pat tern number assigned by CM8A Y A000 1 2 Y 4005 4007 Area Code Development Pattern No 5 7 X X X Area Code 1 8 digits 0000 0255 Route Pattern No 000 255 Specify the LCR selection priority for the Route Pattern number assigned by CM8A Y 4005 4007 1 2 Y 0000 0255 Route Pattern No 000 255 1 1st priority 2 2nd priority 3 3rd priority 4 4th priority XXX ZZ XXX ...

Страница 301: ...tion designate the digits to be added if required 1 2 Y 5000 5255 100 Designation of Digit Addition Pattern No 9000 9255 Digit Addition Pattern No 000 255 NONE No digit addition 1 2 Y 9000 9255 Digit Addition Pattern No 000 255 0 Entry of digit code to be added X X X Digits to be added Maximum 32 digits Specify the maximum number of sending dig its dialed by the calling party The maximum number of...

Страница 302: ...00 255 157 Type of Number of Called Party Num ber 00 Unknown 01 International number 02 National number 03 Not used 04 Subscriber num ber 05 Not used 06 Not used 07 Not used NONE Unknown 00 Unknown 01 Level 2 regional number 02 Level 1 regional number 03 PSTN specific number 04 Local number 05 Not used 06 Abbreviated number 07 Not used NONE Unknown B CM8A For E 164 For private numbering plan C ...

Страница 303: ...bering Plan Iden tifier 1 2 Y 5000 5255 LCR TR Pattern No 000 255 158 Called Party Numbering Plan Identifier 00 Unknown 01 ISDN Telephone Numbering Plan E 164 02 Not used 03 Data Numbering Plan X 121 04 Telex Numbering Plan F 69 05 Not used 06 Not used 07 Not used 08 National Numbering Plan 09 Private Numbering Plan NONE No data C CM8A END ...

Страница 304: ...r 2 Q SIG FEATURES 2 28 NWA 088654 001 Rev 1 0 94ch2001 fm Q SIG FEATURE PROGRAMMING Q SIG FEATURE PROGRAMMING Overlap Sending Q SIG For EMEA Russia Page 2 29 Overlap Receiving Q SIG For EMEA Russia Page 2 32 ...

Страница 305: ...on procedure 1 2 Y 206 00 63 Trunk Route No 0 En bloc call origination and overlap call origination 1 En bloc call origination only Assign the number of division digits 1 2 Y 207 00 63 Trunk Route No 00 31 0 digit 31 digits 63 No data Specify the maximum number of sending dig its to be dialed by Calling Party The maximum number of sending digits in cluding the area codes should be assigned to each...

Страница 306: ... does not contain a called party number message is not enabled assign the second data to 0 NOTE 2 This command should be assigned to incoming trunk route when send ing DT to calling party NOTE 3 This command should be assigned to both incoming trunk route and outgoing trunk when the message does not contain a called party num ber is not enabled 1 2 Y 244 00 63 Trunk Route 0 To send DT of own offic...

Страница 307: ...ion is same as the Progress Description 2 To send DT from opposite office own office Not sent when DT is not sent from opposite office 3 Not sent Assign Progress Description by Overlap Send ing Q SIG NOTE 1 This command is effective when the second data of CM35 Y 270 is as signed to 1 NOTE 2 This command should be assigned to outgoing trunk route 1 2 Y 271 00 63 Trunk Route 1 4 8 Progress Descript...

Страница 308: ...n No 806 6 digits Station No 807 7 digits Station No 808 8 digits Station No Assign the access code for LCR Group 0 3 1 2 Y 0 3 Numbering Plan Group 0 3 X XXXX Access code A126 LCR Group 0 A127 LCR Group 1 A128 LCR Group 2 A129 LCR Group 3 Assign an Area Code Development Pattern number to each LCR Group 1 2 Y A000 0 3 LCR Group 0 3 4000 4007 Area Code Development Pat tern No 0 7 Assign a Route Pat...

Страница 309: ...ONE No digit addition 1 2 Y 9000 9255 Digit Addition Pattern No 000 255 0 X X X Digits to be added Maximum 32 digits X 0 9 A B C Fixed Pause D Programmable Pause For area code deletion designate the digits to be deleted 1 2 Y 5000 5255 LCR Pattern No 000 255 152 Deletion of all digits of the area code assigned by CM8A Y 4000 4007 0 To delete 1 Not deleted To distinguish the maximum number of digit...

Страница 310: ...ed to each area code 1 2 Y 0 7 Area Code Development Pattern No 0 7 assigned by CM8A Y A000 X X X Area code dialed Maximum 8 digits 01 24 1 digit 24 digits 25 79 25 digits 79 digits Specify the system operation when the PBR T302 time out occurs 1 2 655 0 Stop connecting 1 Keep connecting Specify the timing for the PBR timer and T302 timer 1 2 Y 0 112 03 99 3 99 seconds 1 second increments If no da...

Страница 311: ...e does not con tain a called party number mes sage is not enabled assign the second data to 0 NOTE 2 This command should be assigned to incoming trunk route when send ing DT to calling party NOTE 3 This command should be assigned to both incoming trunk route and outgoing trunk when the message does not contain a called party num ber is not enabled 1 2 Y 244 00 63 Trunk Route 0 To send DT of own of...

Страница 312: ...tion is same as the Progress Description 2 To send DT from opposite office own office Not sent when DT is not sent from opposite office 3 Not sent Assign Progress Description by Overlap Send ing Q SIG NOTE 1 This command is effective when the second data of CM35 Y 270 is as signed to 1 NOTE 2 This command should be assigned to outgoing trunk route 1 2 Y 271 00 63 Trunk Route 1 4 8 Progress Descrip...

Страница 313: ...ev 1 0 94ch3001 fm UNIVERGE SV9300 Networking Manual Chapter 3 REMOTE UNIT OVER IP FEATURES This chapter explains the system outline system conditions pro gramming procedure and sample setup for Remote UNIT over IP system ...

Страница 314: ...s and maintains the operation of Remote Units as one single system If a communica tion failure occurs between the Main Unit and Remote Unit the Remote Unit automatically changes over to a survival mode and operates as a stand alone system Following figure shows an image of Remote UNIT over IP system System Outline of Remote UNIT over IP Main Unit PSTN GSTN Remote Unit 2 Remote Unit 3 IP Network LA...

Страница 315: ...onnected via Peer to Peer or VoIPDB If the communications between Main Unit and Remote Unit are interrupted the Remote Unit starts a survival mode operation after the system reset Outline of Survival Mode Operation Remote Unit system watches a Keep Alive signal sent from Main Unit regularly If a line failure occurs Keep Alive signal is not received Remote Unit resets the own system and starts surv...

Страница 316: ...4ch3001 fm SYSTEM OUTLINE Survival Mode Operation Outline Router PSTN GSTN Main 3 Auto registration of IP Multiline Terminal to Remote Unit 1 Detect link down to Main Unit Remote Router IP Network DOWN 2 System reset and change over to survival mode Multiline Terminal ...

Страница 317: ...a Remote UNIT over IP system when an IP Station user and IP Station or only an IP Station user moves to another unit in the destination unit visitor unit this feature allows the IP Station user to use the station number that had been used in the original unit home unit Router PSTN GSTN Main Main Office Administrator Remote Office Administrator 2 Press the button and the message is display on LCD L...

Страница 318: ...cally gets the data from Main Unit when Remote Unit starts In normal operation Main Unit automatically copies the system data to Remote Unit through the network at the time set by CM43 Y 7 once a day This feature is not compatible with Fusion service of 2400 IPX The RUN LED of Remote Units CPU blade flash at 60 IPM in normal mode and 120 IPM in survival mode When the CPU blade VoIPDB IP Station is...

Страница 319: ...The license condition for Remote Unit in survival mode is changed so that the same number of li censes as the Main Unit can be used for a definite period of time from survival mode start By this change of license condition all IP terminals which were registered in the Main Unit in the normal mode can be registered to Remote Unit during the survival mode The functional conditions are as follows Thi...

Страница 320: ...t each Remote Unit is not available because Main Unit corrects all call metering through the whole system If a call is originated from the COT at Remote Unit it is charged as the call originated from the COT at Main Unit The services requiring continuous voice transmission such as Internal Zone Paging should not be used at Remote Unit considering the traffic on the network Multiple line service sh...

Страница 321: ...s if the communications to Main Unit are possible When the Remote Unit regards that the communications are possible Communication er ror restoration between Main Unit and Remote Unit Fault occurrence kind No 052 is registered to the CPU blade of Main Unit at 20 seconds later from the predetermined time set by CM0B Y 1XX 81 When Remote Unit on survival mode regards that the communications to Main U...

Страница 322: ... path connection even if the system data copy is not activated to the Remote Unit After completing all expansions for LC DLC COT blades be sure to execute the system data copy to the Remote Unit CMEC Y 8 Note that the expanded data will not be added if the Remote Unit starts survival mode operation be fore the system data copy Conditions for Link Down Notice Link Down Notice is available only for ...

Страница 323: ...he link between Main Unit and Remote Unit recov ers and the Remote Unit starts subordinate operation to the Main Unit normal mode the flashing lamp of the button goes out COLOR AND STATE OF BUTTON STATE AND OPERATION LCD DISPLAY Red Flashing Momentarily 0 125 seconds ON 0 125 seconds OFF Link Down occurrence Red Flashing Slowly 0 5 seconds ON 0 5 seconds OFF Press the button after Link Down occurr...

Страница 324: ...nge the setting of the primary DRS to the address of the visitor unit You cannot automatically change this setting with SV9300 auto setting is possible if using a DHCP server Also after moving to the visitor unit change the IP address subnet mask and default gateway For the way of setting with IP Station refer to IP Station SETUP in the System Manual Even if you execute the system data backup syst...

Страница 325: ...ion number has been set by CM12 Y 39 50 For the visitor station in the visitor unit the tenant number set by CM0B Y 1XX 11 is effective even if the tenant number has been set by CM12 Y 04 After moving to a Remote Unit the IP Station operates according to the conditions of the Remote Unit The last number redial and stack dial data of IP Station is lost when moving to another unit If only an IP Stat...

Страница 326: ...S address IP address subnet mask and default gateway ad dress with the IP Station or automatically set them with the DHCP server NOTE 4 Do the login operation enter station number password You can log into the visitor unit When only an IP Station user moves to a visitor unit 1 Log out with the logout operation 2 Move to the visitor unit 3 Do the login operation enter station number password at the...

Страница 327: ...is displayed on the LCD of the IP Station 3 Press the Yes key The IP Station at the original unit is logged out You can log into the visitor unit When an IP Station user and IP Station move to a visitor unit and then return to the home unit 1 Log out with the logout operation 2 Move to the home unit 3 Manually change the primary DRS address IP address subnet mask and default gateway ad dress with ...

Страница 328: ... with the DHCP server NOTE 1 3 Do the login operation enter station number password You can log into the home unit When only an IP Station user moves to a visitor unit and then returns to the home unit without doing the logout operation NOTE 2 1 Without doing the logout operation move to the home unit 2 Do the login operation enter station number password with your own IP Station at the home unit ...

Страница 329: ...on within own office When a station places a call on hold and originates a call to another station When a call terminates from DID trunk to a station This service is not available when the destination is a virtual station a station in another office a network station or with trunk origination via other units This service is available when the destination is trunk termination via other units This s...

Страница 330: ...ing station However charging for the Remote Unit in survival mode is not possible ISDN CPN Calling Party Number of ISDN Alternative Routing is as follows When a call originated from a station to other station sends the calling party number of the originated station When a call originated from a trunk to other station sends the calling party number of the terminating station Priority of ISDN CPN Ca...

Страница 331: ...ber setting is required to each tenant of destination station Destination number of each tenant is assigned by CM64 Y 13 If system data of destination number of each tenant is not copied to origination station unit ISDN Alternative Routing is not performed c Destination number setting for each tenant and Subaddress DID number setting to each tenant of the destination station and called party subad...

Страница 332: ...Inter tenant Connection Restriction of Inter tenant Connection Call Forwarding All Calls Split Call Forwarding All Calls Call Forwarding All Calls of Mobility Access Call Forwarding All Calls of Mobility Access Alternative ISDN Connection when Remote Unit in survival mode CID Call Routing per each station Alternative ISDN Connection when Remote Unit in survival mode CID Call Routing per each stati...

Страница 333: ...4 Save the system data of Main Unit by PCPro STEP5 Set the SENSE switch of 0 CPU to E Off line and push the RESET switch of 0 CPU STEP6 Clear the system memory of Remote Unit by CM00 1 STEP7 Load the system data saved in STEP4 to all Remote Units using PCPro STEP8 Assign the Unit numbers for Remote Unit to each CPU blade of Remote Units by CM0B Y 000 90 Page 3 41 STEP9 Set the SENSE switch of 0 CP...

Страница 334: ... STEP5 Clear the system memory of Remote Unit by CM00 1 STEP6 Assign the IP address of Main Unit and own IP address to the CPU blade of Remote Unit to be additionally installed STEP7 Assign own Unit number to the CPU blade of Remote Unit to be additionally installed by CM0B Y 000 90 Page 3 41 STEP8 Execute the system data backup to the Flash ROM of CPU blade of Remote Unit STEP9 Set the SENSE swit...

Страница 335: ...ording to each of programming procedure System data set to the CPU blade of Main Unit 1 Data for Main Unit Operation 2 Data for Remote Unit Operation System data set to the CPU blade of Remote Unit System data set to the CPU blades both of Main Unit and Remote Unit NOTE 1 VoIPDB Data NOTE LAN Data for Main Unit and Remote Unit must be set to the CPU blades both of Main Unit and Remote Unit when an...

Страница 336: ...m the following contents a Remote UNIT over IP system Number of Remote Unit IP network etc b IP address of the Main Unit and Remote Unit Programming Procedure to Main Unit START Remote UNIT over IP VoIPDB Data Assignment END Page 3 27 Remote UNIT over IP VLAN Data Assignment Page 3 29 Survival Mode Assignment Page 3 30 Setting System Data Copy Page 3 31 Remote UNIT over IP Link Down Page 3 32 Noti...

Страница 337: ...m the system data to each CPU blade of Remote Units according to the following procedure Programming Procedure to Remote Unit NOTE Set this data to the CPU blade of Remote Unit only when an additional Remote Unit is installed START END Remote UNIT over IP VoIPDB Data Assignment Page 3 27 NOTE Unit Number for Remote Unit Assignment Page 3 41 NOTE ...

Страница 338: ...Main Unit See Setting A law µ law in the System Manual 2 Setting A law µ law for Remote Unit For EMEA DESCRIPTION DATA Specify the A law µ law for the Main Unit Remote Unit NOTE Set the same value as Main Unit CM04 Y 10 13 You cannot set both of A law and µ law in the same Remote UNIT over IP system 1 2 Y 10 59 Remote Unit01 50 00 0 A law 1 µ law 2 Not used 3 Depends on the CPU START CM04 END ...

Страница 339: ...ds 1 2 Y 1XX VOIP Port 1 Unit No 02 50 01 XXX XXX XXX XXX 255 0 0 0 255 255 255 252 Subnet Mask Maximum 15 digits NONE No data Assign the Default Gateway Address for the VoIPDB NOTE 1 The second data must be entered including the periods NOTE 2 Only one Default Gateway Address can be set for the system 1 2 Y 1XX VOIP Port 1 Unit No 02 50 02 XXX XXX XXX XXX 0 0 0 1 255 255 255 254 Default Gateway A...

Страница 340: ... Re mote Unit Port No for each Remote Unit Common Port Setting Data Remote Unit No And set the port number that is not used by other purposes 1 2 Y 1XX VOIP Port 1 Unit No 02 50 40 01024 65534 DHM Self Port No 1024 65534 NONE 3300 3300 3401 102 ports are used Assign the communication mode and the com munication speed for the LAN Interface of the CPU blade in the Remote Unit NOTE 1 Assign the commu...

Страница 341: ...the Remote Unit NOTE Assign the IP Address and the Subnet Mask that have been set by CM0B Y 0XX 1XX 00 01 1 2 Y 1XX VOIP Port 1 Unit No 02 50 50 0 To provide Specify the priority of the VLANS NOTE The higher number has higher pri ority 1 2 Y 1XX VOIP Port 1 Unit No 02 50 51 0 7 Priority 0 7 NOTE Assign the VLAN ID to the Remote Unit NOTE 1 One VLAN ID can be set per system NOTE 2 VLAN ID 0 is not ...

Страница 342: ... Provide the system with the automatic change over to normal mode from survival mode after the connection between the Main Unit and Re mote Unit returned to normal condition NOTE When providing the system with the automatic changeover to normal mode second data 0 the change over of modes may occur frequently under the heavy traffic network 1 2 Y 1XX VOIP Port 1 Unit No 01 50 83 0 To provide Specif...

Страница 343: ... copy is executed from the low Remote Unit number to high Remote Unit number NOTE 3 The start time for system data copy may gain loss about three minutes from the time you set 1 2 Y 7 00 HH MM HH 00 23 Hour MM 00 59 Minute 9999 Not copy the system data auto matically NONE 0200 2 00 a m DESCRIPTION DATA Specify the unit number that is executed the system data copy read the state of system data copy...

Страница 344: ...F1663 Event Occurrence Notice button No 01 64 NONE No data Specify the start time to notify the link down to the Multiline Terminal after the disconnection between Main Unit and Remote Unit is detect ed NOTE Assign the shorter time than the time for automatic changeover to surviv al mode assigned by CM0B Y 1XX 80 If the longer time is set the link down cannot be notified 1 2 Y 1XX VOIP Port 1 Unit...

Страница 345: ...ime Zone to the location number assigned by CM0B Y 1XX 10 1 2 Y 10 00 63 Location No 00 63 Time Zone See the table below NONE No Time Zone NOTE 1 System clock should be assigned by CM02 NOTE 2 After changing the data system data copying to Remote Unit by CMEC Y 8 is required START CM0B CM67 15 minute increments 2nd Data Time Zone A2345 System Clock 23 45 A2330 System Clock 23 30 A2315 System Clock...

Страница 346: ...SSIGNMENT DESCRIPTION DATA Assign the Daylight Saving Time to the loca tion number assigned by CM0B Y 1XX 10 NOTE After changing the data system data copy to Remote Unit by CMEC Y 8 is required 1 2 Y 30 00 63 Location No 00 63 0 To operate with Daylight Saving Time 1 hour NONE To operate with Standard Time A CM67 END ...

Страница 347: ...ta 0 when making an outgoing call using the trunk route of destination unit visitor unit Also set the second data 1 when making an outgoing call using the trunk route of original unit home unit 1 2 Y 196 00 15 0 Tenant of the visitor unit to which IP Station logged in CM0B Y 1XX 11 1 Station tenant CM12 Y 04 Assign the tenant number for IP Station ac commodated in the Unit when IP Station log in t...

Страница 348: ...attern number assigned by CM8A Y A000 1 2 Y 4000 4007 Area Code Development Pattern No 0 4 X X X Area Code Maximum 8 digits 1000 1015 Tenant Pattern No 00 15 Assign a Tenant number and a Route Pattern number to the Tenant Pattern number assigned by CM8A Y 4000 4007 NOTE Set the tenant number assigned by CM0B Y 1XX 11 or CM12 Y 04 to the first data 1 2 Y 1000 1015 Tenant Pattern No 00 15 00 63 Tena...

Страница 349: ... A Allow ISDN Alternative Routing in Remote Unit survival mode 1 2 Y 217 00 15 Service Restriction Class A as signed by CM12 Y 02 0 Allow Allow ISDN Alternative Routing in Remote Unit survival mode when trunk call is received to the required trunk routes 1 2 Y 276 00 63 Trunk Route No 0 Allow Assign a Tenant number to each station 1 2 Y 04 X XXXXXXXX Station No 00 Tenant No 00 01 63 Tenant No 01 6...

Страница 350: ...ative Routing disabled Assign the destination of each tenant for ISDN Alternative Routing in Remote Unit survival mode if the 2nd data of CM64 Y 12 is set to 1 2 1 2 Y 13 00 63 Tenant No of Terminating Unit as signed by CM12 Y 04 X XXXX Destination C O line number Maximum 26 digits NONE No data Assign the destination of each station for ISDN Alternative Routing in Remote Unit survival mode if the ...

Страница 351: ...ation number first digit 1 2 803 3 digits station number for the station number first digit 2 3 803 3 digits station number for the station number first digit 3 4 803 3 digits station number for the station number first digit 4 90 101 Route Access RT 01 for trunk access code 90 91 102 Route Access RT 02 for trunk access code 91 IP Station Multiline Terminal STN 300 Multiline Terminal IP Station ST...

Страница 352: ...it 05 Remote Unit 05 for station No 200 IP Station CM15 Y 217 15 0 Allow ISDN Alternative Routing CM30 Y 01 000 022 01 Tenant number 01 for PRI trunk Main Unit 100 02 Tenant number 02 for BRI trunk Remote Unit 101 CM35 Y 276 03 0 Allow ISDN Alternative Routing for Incoming trunk route 03 04 0 Allow ISDN Alternative Routing for Incoming trunk route 04 CM64 Y 11 01 90 Trunk access code for tenant 01...

Страница 353: ... DATA Assign the Unit number for Remote Unit to each Remote Unit NOTE 1 This command should be set in each Unit NOTE 2 The registration clear of this data is available only in off line mode NOTE 3 Set the SENSE switch of the CPU blade to 0 when operating the Unit as Unit No 05 50 for Remote Unit The Unit functions as the Unit No set by this data 1 2 Y 000 90 05 50 Unit No for Remote Unit NONE Unit...

Страница 354: ... CONFIGURATION The figure below shows the sample system configuration and the accommodated hardware in the Main Unit and Remote Unit of the sample system Sample System Configuration Main Unit Router SV9300 Multiline Terminal SLT Remote Unit Router IP Station IP Station IP Station IP Station GSTN SV9300 Multiline Terminal ...

Страница 355: ... IP FEATURES 3 43 NWA 088654 001 Rev 1 0 94ch3001 fm SAMPLE SYSTEM CONFIGURATION Accommodated Hardware in Main Unit Accommodated Hardware in Remote Unit GCD 8DLCA GCD 8LCF 04 05 06 01 02 03 GCD 8DLCA GCD 4COTA 04 05 06 01 02 03 ...

Страница 356: ...e Unit in this system is 05 2 A CODEC within the unit is G 711 64 Kbps and a CODEC between units is G 729 8 Kbps Main Unit Router Remote Unit Router GSTN Location 01 Location 00 SV9300 SV9300 Station No 200 Station No 201 Station No 250 Station No 260 Station No 300 Station No 301 Station No 350 VoIPDB 172 16 1 1 ETHERNET 192 168 1 1 VoIPDB RTP 172 16 1 2 VoIPDB RTP 172 16 2 5 ETHERNET 192 168 2 1...

Страница 357: ...Main Unit ETHERNET 0B 001 00 192 168 1 1 Unit No 01 Refer to Command Manual 3 Subnet Mask for Main Unit ETHERNET 0B 001 01 255 255 255 0 4 IP address for Main Unit VoIPDB 0B 101 00 172 16 1 1 Unit No 01 Page 3 27 5 Subnet Mask for Main Unit VoIPDB 0B 101 01 255 255 255 000 6 Default Gateway address for Main Unit VoIPDB 0B 101 02 172 16 1 254 7 IP address for Remote Unit ETHERNET 0B 005 00 192 168 ...

Страница 358: ...250 01 250 My line setting 19 93 250 250 Prime line setting 20 Registration of IP Station in Main Unit 10 01 0000 F200 Station No 200 Refer to System Manual 21 12 24 200 0 Kind of IP Station 22 20 1 1 803 3 digits station 23 90 00 200 01 200 My line setting 24 93 200 200 Prime line setting 25 12 39 200 00 Registration of IP Sta tion to Location No 00 26 Registration of IP Station in Main Unit 10 0...

Страница 359: ...0 My line setting 37 93 350 350 Prime line setting 38 Registration of IP Station in Remote Unit 10 01 0002 F300 Station No 300 Refer to System Manual 39 12 24 300 0 Kind of IP Station 40 20 2 1 803 3 digits station 41 90 00 300 01 300 My line setting 42 93 300 300 Prime line setting 43 12 39 300 01 Registration of IP Sta tion to Location No 01 44 Registration of IP Station in Remote Unit 10 01 000...

Страница 360: ... 4 DTMF 56 35 005 00 0 1 Release signal does nor arrive Release signal arrives 57 Registration of VoIPDB RTP in Main Unit 0B 201 00 172 16 1 2 IP Address of VoIPDB RTP Page 3 27 58 0B 101 10 00 Registration of Unit to Location No 00 Page 3 35 59 Registration of VoIPDB RTP in Remote Unit 0B 205 00 172 16 2 5 IP Address of VoIPDB RTP Page 3 27 60 0B 105 10 01 Registration of Unit to Location No 01 P...

Страница 361: ...et Mask for Main Unit VoIPDB 0B 101 01 255 255 255 000 5 Default Gateway address for Main Unit VoIPDB 0B 101 02 172 16 1 254 6 IP address for Remote Unit ETHERNET 0B 005 00 192 168 2 1 Remote Unit No 05 Refer to Command Manual 7 Subnet Mask for Remote Unit ETHERNET 0B 005 01 255 255 255 0 8 IP address for Remote Unit VoIPDB 0B 105 00 172 16 2 1 Remote Unit No 05 Page 3 27 9 Subnet Mask for Remote ...

Страница 362: ... the Remote Unit on The communication between Main Unit and Remote Unit starts STEP3 Confirm that the system data has been copying from Main Unit to Remote Unit After 30 seconds the RUN LED on CPU blade at Remote Unit flashes at 30 IPM STEP4 Confirm that the system data is backed up in Flash ROM of CPU blade at Remote Unit SYSD LED on the CPU blade turns on and the data back up starts It takes two...

Страница 363: ...inued on next page PORT TYPE DESTINATION DEFAULT PORT No REMARKS NUMBER OF PORT USED REFERENCE PAGE Port for Remote Unit Control UDP SV9300 Main Unit 3300 1024 65534 Assign by CM0B Y 1XX 40 DHM Self Port Communication port between the Main Unit and Remote Unit Common Port 1 Page 3 28 SV9300 Main Unit 3300 Port per Remote Unit CPU CPU Port per Remote Unit Setting data of CM0B Y 1XX 40 Unit No 1 Uni...

Страница 364: ...ORT TYPE DESTINATION DEFAULT PORT No REMARKS NUMBER OF PORT USED REFERENCE PAGE Port for Remote Unit Control UDP SV9300 Remote Unit 3300 DHM Self Port Communication port between the Main Unit and Remote Unit Common Port Port per Remote Unit CPU CPU 3300 fixed 1 Page 3 28 SV9300 Remote Unit 3300 Port per Remote Unit CPU CPU 1 Unit Page 3 28 ...

Отзывы: