Chapter 1 CCIS FEATURES
1-137
NWA-088654-001 Rev.1.0
94ch1005.fm
CENTRALIZED DAY/NIGHT MODE CHANGE-CCIS
CENTRALIZED DAY/NIGHT MODE CHANGE-CCIS
General Description
This feature switches the Day/Night Mode of a remote office, linked to the main office (2400 IPX) via
CCIS, in accordance with the Day/Night Mode switching on the Attendant Console at the main office.
• For Satellite Office
If the Attendant Console is required in the Satellite Office, the following programming is required.
DESCRIPTION
DATA
Assign as ineffective Trunk Restriction Class
change by NT (Night) switch on DESKCON.
NOTE:
A reset by CM60 Y=90>0: 0 is
required after this data setting.
•
(1)
(2)
Y=02
0-7: DESKCON No.
1 : Ineffective
Assign as ineffective outgoing call restriction
on Night Mode by NT switch on DESKCON.
NOTE:
A reset by CM60 Y=90>0: 0 is
required after this data setting.
•
(1)
(2)
Y=04
0-7: DESKCON No.
1 : Ineffective
Assign as ineffective Day/Night Mode Change
by NT switch on DESKCON.
NOTE:
A reset by CM60 Y=90>0: 0 is
required after this data setting.
•
(1)
(2)
Y=06
0-7: DESKCON No.
1 : Ineffective
SATELLITE OFFICE
MAIN OFFICE
ATT
CCIS
2400 IPX
SV8300/
SV9300
START
CM60
END