A dedicated 100VAC/120VAC/220VAC/230 – 240VAC 50Hz/60Hz circuit located
within seven feet of the chassis is required. A separate dedicated outlet for each
chassis should be installed.
5.1 Power Supply Specifications
AC Power Supply:
Dedicated 15 Amp circuit
Power Requirements: 120 VAC @ 15A Controlling/Base Chassis
LCA
Twisted Pair
600 ohms (Including the SLT)
3,281 ft (1,000m) with 26 AWG
4,920 ft (1,500m) with 24 AWG
8,202 ft (2,500m) with 22 AWG
OPX
Twisted Pair
1,500 ohms or less (Including the SLT)
13,123 ft (4,000m) with 26 AWG
20,997 ft (6,400m) with 24 AWG
14,777 ft (10,600m) with 22 AWG
Mixing digital and analog ports through the same 25-pair cable runs is not
recommended.
Table 5-18 Cabling Requirements
Connected Equipment
Cable
Music on Hold and Background Music Sources
Hi-Fi Shielded Audio Cable
External Amplifier
Hi-Fi Shielded Audio Cable
ITL Cabling
Cat 5 Straight Data Network Cable
– 328.1 ft (100m) maximum
distance
IP Video Doorphone
Maximum 100m (by LAN cable)
Table 5-17 Cable Connection Between Analog Port and Single Line Equipment (Continued)
Connected
Equipment
Cable
Maximum Feet from Connected Equipment
to Telephone
NOTE
Double Pole/Neutral Fusing (power supply fuses are located at both the L
and N side).
Содержание Univerge SV9100
Страница 1: ...General Description Manual NDA 31581 ISSUE 2 0 SV9100...
Страница 2: ......
Страница 4: ......
Страница 20: ...iv Table of Contents Issue 2 0...
Страница 22: ...vi List of Figures Issue 2 0...
Страница 134: ...Issue 2 0 2 96 Features...
Страница 189: ......
Страница 190: ...General Description Manual NEC Corporation of America Issue 2 0 SV9100...