1329
Voice Over
Description
Voice Over lets a user interrupt a busy station user that is on another call. With Voice Over, the busy
extension user hears an alert tone followed by the voice of the interrupting party. The extension user
receiving the Voice Over can respond to the interrupting party without being heard by the original caller.
If desired, the user can easily switch between their original caller and the interrupting co-worker. The
original caller and the interrupting party can never hear each other.
Example:
Voice Over could help a lawyer waiting for an urgent call. While on a call with another client, the
lawyer’s
paralegal could announce the urgent call as soon as it comes in. The lawyer could then give the paralegal
instructions how to handle the situation
– all without the original client hearing the conversation.
Both multiline terminal users and 500/2500 set users can initiate and receive a Voice Over.
To enable Voice Over, a multiline terminal can have a function key programmed for Voice Over. In
addition to one- touch Voice Over operation, the key shows the Voice Over status as follows:
When the key is . . .
You are . . .
Off
Not using Voice Over
Flashing (Red)
Listening to the interrupting party
On (Green)
Responding to the interrupting party
Conditions
While active, Voice Over uses a Conference circuit on a GCD-CP10. Refer to the
Conference feature for Conference circuit programming.
Voice Over can interrupt a trunk call only if the trunk is set up for at least six seconds.
Do not use Voice Over to a user on speakerphone as the conversation may be heard by the
outside party.
When a multiline terminal user performs Voice Over, the speech path is 1-way from the
originator to the destination.
The Voice Over Access Code can be assigned on a Programmable Function Key.
An override tone is sent to both calling and called parties. A single line telephone user can
receive Voice Over. After a Tone Override is heard, Voice Over can be set.
When a Programmable Function Key (programmed with the Voice Over Access Code) is
pressed, the LED lights while responding to the page.
When a multiline terminal has a Handsfree Unit programmed, the Voice Over call can be
received and answered handsfree.
When Data Line Security is assigned to a station, the Voice Over to the station is disabled.
An extension user cannot Voice Over to another extension user in a Conference.
If you place a call on hold and then Voice Over to a busy extension, the call on hold does
not transfer to the busy party when you end the Voice Over.
Содержание Univerge SV9100
Страница 1: ... SV9100 Features and Specifications Manual Rev 1 2 March 2016 ...
Страница 64: ...64 Required Component s None ...
Страница 238: ...238 Walking Code Restriction 663 ...
Страница 239: ...239 Temporary Code Restriction Override service code be changed 775 ...
Страница 285: ...285 Single Line Telephone 1 Lift the handset A fast busy is heard 2 Dial 759 3 Hang up ...
Страница 332: ...332 Circular Routing Department Calling Circular Routing CALL 1 CALL 2 CALL 3 CALL 4 ...
Страница 406: ...406 Trunk Distinctive Ringing Flow Chart ...
Страница 407: ...407 ICM Distinctive Ringing Flow Chart ...
Страница 442: ...442 CCIS Standard Calls ...
Страница 447: ...447 CCIS VE Standard Calls ...
Страница 456: ...456 CPN sent when making a 911 call across CCIS trunks from a terminal ...
Страница 461: ...461 CCIS VE 911 Calls ...
Страница 519: ...519 3 Dial Relay Number 0 8 0 is for the relay on the GCD CP10 1 8 are relays on the PGD 2 U10 ADP ...
Страница 637: ...637 Cascade Message Notification Flow Chart 1 ...
Страница 638: ...638 Cascade Message Notification Flow Chart 2 ...
Страница 639: ...639 Cascade Message Notification Flow Chart 3 ...
Страница 655: ...655 Cascade Message Flow Chart 1 ...
Страница 808: ...808 DTI U40 ETU Programming Flowchart for ISDN PRI Answering Calls the GCD PRTA Overlap ...
Страница 813: ...813 ...
Страница 844: ...844 None Related Features None Guide to Feature Programming None Operation None ...
Страница 915: ...915 Communications Interface feature for more ...
Страница 916: ...916 ...
Страница 917: ...917 Operation None ...
Страница 948: ...948 Operation Normal call handling procedures for single line telephones apply ...
Страница 1015: ...1015 Related Features None Guide to Feature Programming None Operation None ...
Страница 1026: ...1026 Operation Refer to Central Office Calls Answering ...
Страница 1030: ...1030 Multiline Room Monitoring ...
Страница 1031: ...1031 Single Line Telephone Room Monitoring ...
Страница 1145: ...1145 SMDR flowcharts are located on the following pages SMDR with a GCD CP10 Connection Ethernet ...
Страница 1146: ...1146 SMDR Flowchart Continued ...
Страница 1147: ...1147 SMDR Flowchart Continued ...
Страница 1148: ...1148 SMDR Flowchart Continued Operation Once installed and programmed SMDR operation is automatic ...
Страница 1195: ...1195 System Caller Log Example 2 4 LED Operation On Red Other Using On Green Using Off Not Using ...
Страница 1216: ...1216 To cancel Automatic Headset repeat these steps 4 Press the Headset key Program 15 07 or SC 851 05 to go off hook ...
Страница 1371: ...1371 ...
Страница 1400: ...1400 To answer off hook signaling 2nd call and 2nd caller disconnect the call NOTE ...
Страница 1402: ...1402 SV9100 Features and Specifications Manual NEC Enterprise Solutions ...