Chapter 4 Standard Mode
4-12
NWA-033628-001 Rev.1.0
[Implement] Category
STEP3:
Click the [OK] button.
You are directed back to the [Quick Setup] screen. Checked mark appears to the right of but-
ton [3].
The IP addresses of maintenance port and VOIP port have now been set.
Numbering Plan Setting (CM20)
Set a station and trunk route numbering plan in these steps:
STEP1:
Click the [4] button in the [Quick Setup] screen.
The [4. Setting of Numbering Plan] screen is displayed in the work window.
No. Item
Description
(5)
IP Address field
Enter the IP address (RTP) of the VOIP port.
• 0.0.0.1 to 255.255.255.254 (default: 172.16.1.2)
• Up to 8 IP addresses (RTP) can be entered.
• One IP address (RTP) is required as per 16 channels set of RTP chan-
nels used.
(6)
[Fill In] button
Click to enter up to 7 IP addresses continuously in relation to the IP
address (RTP) of the VOIP port entered on the first line in (5).
• The number of IP addresses that can be entered continuously depends
on the number of RTP channels used selected in (4).
(7)
[Clear] button
Click to reset the complete set of data to the defaults.