SOPHO
IP 5000/SOPHO IP6000
Command Reference Guide
135
for each set. This serial interface has the same logic features of synchronous
serial interface.
The serial interface is numbered in the form of serial interface-number :set-
number. The interface-number starts from the maximum serial interface
number plus 1, and the set-number is the number of the channel-set.
Only one timeslot bundling mode can be supported on one CE1/PRI interface
during a time period. In other words, this command cannot be used together
with the
pri-set
command.
For related command, see
pri-set.
Example
Bundle the timeslots 1, 2, 5, 10-15, and 18 of the CE1/PRI interface into
channel-set 0.
[NEC-PHILIPS-E1 3/0/0]
channel-set 0 timeslot-list 1,2,5,10-15,18
Make the same configuration on the CE1/PRI interface on the remote router.
[NEC-PHILIPS-E1 3/0/0]
channel-set 0 timeslot-list 1,2,5,10-15,18
clock
Syntax
clock { master | slave }
undo clock
View
CE1/PRI interface view
Parameter
master
: Adopts the internal clock mode.
slave
: Adopts the line clock mode.
Description
Using the
clock
command, you can set the clock mode on a CE1/PRI interface.
Using the
undo clock
command, you can restore the default clock mode on the
interface.
By default, the CE1/PRI interface adopts the line clock mode (slave).
When a CE1/PRI interface is working as DCE, chose the internal clock for it,
that is, master clock mode. When it is working as DTE, chose the line clock,
that is, slave clock mode for it.
Example
Set the clock mode of the CE1/PRI interface to internal clock (
master
) mode.
[NEC-PHILIPS-E1 3/0/0]
clock master
code
Syntax
code { ami | hdb3 }
undo code
View
CE1/PRI interface view