Figure 2-82 1PRIU-C1 LED Indication Pattern of Layer 1 on E1 Unit
Table 2-16 E1 LED Indications
Alarm
Details of the alarm
The LED indication pattern
LOS
LOS (Loss of Signal (Red Alarm))
No Signal (Analog Interface)
Following an alarm blink (red, green, red, green), a red
LED lighting up.
AIS
AIS (Alarm Indication Signal (Blue
Alarm))
Following an alarm blink (red, green, red, green), a red
LED flashes on and off slowly twice
OOF
OOF (Out of Frame (Red Alarm))
Following an alarm blink (red, green, red, green), a red
LED and a green LED flash on and off 3 times simultane-
ously.
RAI
RAI (Remote Alarm Indication (Yellow
Alarm))
Following an alarm blink (red, green, red, green), a green
LED flashes on and off twice.
TS16
TS16 (Receive Time Slot 16 all Alarm)
An alarm blink repeat twice by 1 cycle.
No alarm
System does LED control
3.5 Power Failure Transfer (408E-A1 only)
3.5.1 General
In the event of AC power failure, the specified trunks are directly connected to the specified extension
ports as below. And SLT must be connected to the specified extension. The multiline telephone (4W)
does not work when connected to the specified extension port.
Trunk Port No. 5 Extension Port No. 16
Trunk Port No. 9 Extension Port No. 24
Trunk Port No. 13 Extension Port No. 32
SL1000
ISSUE 3.0
2-58
Installation
Содержание SL1000
Страница 1: ...Hardware Manual A50 031170 001 GE ISSUE 3 0 November 2012...
Страница 12: ...MEMO SL1000 ISSUE 3 0 x Hardware Manual...
Страница 16: ...MEMO SL1000 ISSUE 3 0 R 4 Regulatory...
Страница 126: ...MEMO SL1000 ISSUE 3 0 3 8 System Start Up...
Страница 140: ...MEMO SL1000 ISSUE 3 0 4 14 Maintenance...
Страница 149: ...MEMO ISSUE 3 0 SL1000 Hardware Manual 5 9...
Страница 150: ...Hardware Manual NEC Corporation ISSUE 3 0...