5.

In case a 2nd PCB is mounted, insert two Nylon-spacers into the specified holes, and fasten two
Metal-spacers into the specified holes. (Both Nylon and Metal spacers are provided with 408E/
008E/000E/1PRIU)
If no more Expansion interface card is mounted on the 2nd PCB, fasten two screws to secure the
2nd PCB to the top of the 408E/008E/000E/1PRIU.

Expansion Interface Card
(2nd PCB)

J1

J2

Nylon-Spacers

Metal-Spacers

Screws

Expansion Interface Card
(1st PCB)

Screw position

Both sides are 
the same.

2nd EXP. 
PCB

Figure 2-66  Mounting the 2nd Expansion Interface Card

ISSUE 3.0

SL1000

Hardware Manual

2-45

Содержание SL1000

Страница 1: ...Hardware Manual A50 031170 001 GE ISSUE 3 0 November 2012...

Страница 2: ...time without notice NEC Corporation has prepared this document for use by its employees and customers The information contained herein is the property of NEC Corporation and shall not be reproduced w...

Страница 3: ...Multiline Telephones and Optional Equipment 1 8 2 4 1 IP4WW 12TXH A TEL 1 8 2 4 2 IP4WW 24TXH A TEL 1 8 2 4 3 IP4 24TIXH C TEL 1 8 2 4 4 IP4WW 60D DSS A 1 8 2 4 5 DP D 1D 1 9 Section 3 SYSTEM CAPACIT...

Страница 4: ...2 27 2 6 1 Floor Mounting the IP4WW Battery Box 2 27 2 6 2 Wall Mounting the IP4WW Battery Box 2 29 2 6 3 Mounting One KSU on the Battery Box 2 33 2 7 IP4WW Battery Box to KSU Connection 2 36 2 8 IP4W...

Страница 5: ...ine Telephone 2 79 5 3 Installing the DSS Console 2 79 5 3 1 DSS Console Leg Adjustment 2 79 5 3 2 Wall Mounting the DSS Console 2 81 5 4 Installing the Headset 2 82 5 5 Installing the Doorphone Box 2...

Страница 6: ...CAPACITY 5 1 Section 2 SYSTEM SPECIFICATIONS 5 3 2 1 General Precautions 5 3 2 2 Environmental Requirements 5 3 2 3 Operating Conditions 5 3 2 4 Site Requirements 5 3 2 5 AC Power Requirement 5 3 2 6...

Страница 7: ...XH 24TXH 24TIXH IP 2 73 Table 2 23 Doorphone Interface Specifications 2 85 Table 2 24 RJ 61 General Purpose Door Unlock Relay Control Connector J7 2 86 Table 2 25 General Purpose Door Unlock Relay Spe...

Страница 8: ...19 AC Power Cord 2 14 Figure 2 20 Sub Cover Open and Hold 2 15 Figure 2 21 Trunk Cabling 2 16 Figure 2 22 Extension Cabling 2 17 Figure 2 23 PF KT Switch of 408M A1 2 18 Figure 2 24 Cabling 2 19 Figur...

Страница 9: ...cover 2 47 Figure 2 71 Plastic Knockouts on 008E A1 000E A1 2 48 Figure 2 72 Installing the 2BRIDB C1 2 48 Figure 2 73 Mounting the 2BRIDB C1 into the KSU 2 49 Figure 2 74 Replacing the Main Cover 2 4...

Страница 10: ...Mount Screw Guide 2 82 Figure 2 123 Mounting the DSS 2 82 Figure 2 124 Handset Socket 2 83 Figure 2 125 Headset Socket 2 83 Figure 2 126 Doorphone Box and Bracket 2 84 Figure 2 127 Doorphone 2 84 Figu...

Страница 11: ...Battery Socket 4 7 Figure 4 11 Removing the Lithium Battery 4 7 Figure 4 12 Inserting the Lithium Battery 4 7 Figure 4 13 Installing the CPU Card 4 8 Figure 4 14 Display of Multiline Telephone 4 9 Fig...

Страница 12: ...MEMO SL1000 ISSUE 3 0 x Hardware Manual...

Страница 13: ...olid waste management officials for other information regarding the environmentally sound collection recycling and disposal of the battery Sealed lead batteries must be returned to an approved sealed...

Страница 14: ...ss A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures PRODUCT DISPOSAL INFORMATION For Countries in the Euro...

Страница 15: ...isition of these products At www nec unified com weee you can find information about separate disposal and environmentally sound recycling BATTERY INFORMATION Defective or exhausted batteries should n...

Страница 16: ...MEMO SL1000 ISSUE 3 0 R 4 Regulatory...

Страница 17: ...ne extensions by adding up three more expansion KSUs also equipped to support Digital Network BRI PRI E1 IP Trunks SIP H 323 and IP extensions IP VoIP PSTN ISDN Multiline Telephone 4 wire DSS Console...

Страница 18: ...y Box External Battery Box without Batteries BE110250 1101031 IP4WW 408E A1 4 port Loop Start Trunks and 8 port Hybrid Station In terface BE110251 1101032 IP4WW 008E A1 8 port Hybrid Station Interface...

Страница 19: ...ION LIC Encryption License for Multiline IP Telephone 1 li cense per system V1 2 Added BE110754 1101082 SL IP NAPT LIC NAPT License for Multiline IP Telephone 1 license per system V1 2 Added BE110755...

Страница 20: ...Although similar in shape and size as the 1632M KSU the capabilities are not the same The following are included with the 1632ME EXP Power supply 110V 240V 1 external backup battery connector 3 mounti...

Страница 21: ...d is installed in the 1632M KSU or 1632ME EXP and provides a total of four analog trunk and eight hybrid extension ports Install this card to the expansion card slot at Main Expansion KSU Enables to c...

Страница 22: ...n Hard switch All ISDN circuits are not supplied with DC power from the system 2 2 5 IP4WW 1PRIU C1 The 1PRIU is installed in the 1632M KSU or 1632ME EXP providing for either an ISDN Primary Rate Inte...

Страница 23: ...21 daughter board provides additional Voice Response and Voice Mail functionality using a Compact Flash CF interface and a single channel V 34 modem Mount this card onto the CPU card VMDB slot at Main...

Страница 24: ...e featuring Programmable keys 24 Soft Keys 4 LCD 24 digits x 3 lines with Backlit Handsfree Full duplex Interface 2 x RJ45 Ethernet Ports 10Base T 100Base TX for LAN and PC Power Feeding AC Adapter op...

Страница 25: ...2 4 5 DP D 1D This is the Doorphone Box Connects to hybrid port number 6 or 7 on the 408M of each KSU ISSUE 3 0 SL1000 Hardware Manual 1 9...

Страница 26: ...SU 408Mx2 PRIx2 408Ex4 3 4KSU 408Mx3 PRIx3 408Ex6 Trunk Port Analog Trunks COT 16 32 48 48 1KSU 408M 408Ex3 2KSU 408M 408Ex3 x2 3 4KSU 408M 408Ex3 x3 BRI 12 24 36 36 1KSU 2BRIx3 on 008E 000E 2KSU 2BRI...

Страница 27: ...orts 4 VRS ports default Total Max 8 w o MEMDB or 16 w MEMDB CFVML C1 Port increased by license Virtual Extension 50 Relay 2 4 6 8 2 circuits on 408M Power Failure Transfer 4 8 12 12 1PFT circuit on 4...

Страница 28: ...8M Trunk x 4 Extension x 8 Expansion KSU 1632ME A x 3 Main KSU 1632M A Expansion Interface Card 408E Trunk x 4 Extension x 8 008E Extension x 8 Optional 2BRIDB ISDN BRI x 4 000E Extension x 0 Optional...

Страница 29: ...ot 408E or 008E 2BRIDB 1st opt slot 408M 1 KSU 1 KSU 408E or 008E 2BRIDB 2nd opt slot 408E or 008E 2BRIDB 2nd opt slot 408E or 008E 2BRIDB 3rd opt slot SLT only 8 16 24 8 16 24 32 000E 2BRIDB 3rd opt...

Страница 30: ...EXP 2nd Exp KSU 1632ME EXP 3rd Exp KSU Not trunk support 24 48 72 96 Extension 408M 1 KSU 8 16 24 PRI 3rd opt slot Example 2 408 x 1 008 x 1 PRI x 1 34 4 408M 008E 1st opt slot 1 KSU 8 16 PRI 2nd opt...

Страница 31: ...SU s are installed turn the power on off in the following order Expansion 3 KSU Expansion 2 KSU Expansion 1 KSU and then Main KSU 1 1 2 Preparations Make sure the necessary tools screw driver set plie...

Страница 32: ...List Items List of Contents QTY 1632M A KSU 1632M A KSU 1 AC Power Cord AC Power Cord is not attached for IP4 1632M A KSU w o C type 1 Manual CD 1 Screws M4 1x25 4 Wall Mounting Template 1 1632ME A E...

Страница 33: ...RJ45 87654321 Ethernet Cable Connection for SMDR PC Printer PCPro or WebPro etc Pin No Connection 1 Tx 2 Tx 3 Rx 4 5 6 Rx 7 8 For the detail of LED D1 D5 refer to Figure 4 17 Inserting the CF Card on...

Страница 34: ...of KSU The Main KSU 1632M A and Expansion KSU s 1632ME A be mounted on the wall Before installing ensure the appropriate spacing exists as shown below In case of horizontal arrangement refer to Mount...

Страница 35: ...Figure 2 3 Vertical Arrangement of KSUs Due to the limit of extension cable length to connect Main KSU and Expansion KSU s the install location of Main KSU and each Expansion KSU s must be considered...

Страница 36: ...th to connect between Main KSU and Expansion KSU s the install location of Main KSU and each Expansion KSU s must be considered as Figure 2 4 Horizontal Arrangement of KSUs on page 2 6 1 3 3 Mounting...

Страница 37: ...221 285 mm 11 221 180 mm 7 087 2 5 mm 0 098 3 5 mm 0 138 Figure 2 6 Screw Positions Wall Mounting Screws M4 1x 25 4 pcs are attached to the KSU The screw diameter is 4 mm 0 158 to 4 5 mm 0 177 3 Push...

Страница 38: ...eld in the open position Push to hold Open Figure 2 9 Sub Cover Open Position 5 Align the four holes on the back of the KSU with the four screws installed in the wall Hook Screw head Screw head Fasten...

Страница 39: ...ist Items List of Contents QTY EXIFB C1 EXIFB C1 PCB 1 1 4 3 Connectors Location EXIFB C1 J4 J6 J5 J1 J2 J3 Figure 2 11 Connectors of EXIFB C1 Table 2 4 Connectors of EXIFB C1 No Connectors Connectabl...

Страница 40: ...in KSU Sub Cover Sub Cover Tab Tab Figure 2 12 Removing the Sub Cover 3 Loosen two screws and pull out the Main Cover by pressing the two hooks Two screws Hooks Main Cover Figure 2 13 Removing the Mai...

Страница 41: ...ector on the 408M A1 at 1632M A KSU 6 Close the CPU support and make sure the tab A locks into place 7 Cut and remove the Plastic Knockouts as needed for Expansion KSU Main Cover Plastic Knockouts Fig...

Страница 42: ...m View Front View Bottom View EXIFE C1 PCB CPU card EXIFE C1 PCB EXIFE C1 PCB EXIFB C1 PCB EXP 3 EXP 2 EXP 1 EXP LAN EXP EXP Figure 2 17 Connection of KSUs Use attached cables for the above inter conn...

Страница 43: ...Power Requirement A dedicated 100V 120V 220V 230V 240V 50 60Hz circuit located within two meters of the KSU is required A separate dedicated AC outlet is necessary for each KSU Double Pole Neutral Fu...

Страница 44: ...e located at the left side of each KSU The AC power cord is connected to the AC inlet and the commercial AC power socket Do not plug in AC power cord if the KSU Cover is removed Before connecting the...

Страница 45: ...e floor Aerial distribution wiring is not allowed Trunks must be installed with lightning protectors Do not install the Topaz Terminal in the SL system it does not work properly 1 6 3 Trunk Cabling En...

Страница 46: ...m setting must be required when using Audio port instead of Trunk port in the system The External Paging can be set for 408M A1 PCB at each KSU The External MOH and BGM can be set only one port for ea...

Страница 47: ...m Figure 2 22 Extension Cabling While an Analog Telephone port is ringing or MW lamp is flashing on an Analog Phone port do not disconnect the phone from the port or connect another type of the termin...

Страница 48: ...it Refer to Power Failure Transfer on page 2 58 for Power Failure Transfer of 408E A1 1 6 5 2 Power Failure Setting 1 Use Needle nose pliers to change the switch position of J6 from KT to PF as below...

Страница 49: ...her a right or left route Clamp and route cable to outside Cables Cable clamp Figure 2 24 Cabling 2 Cut and remove the Plastic Knockouts as needed from the Sub Cover Sub Cover Plastic Knockouts Figure...

Страница 50: ...damage to equipment do not install the Topaz Battery Box DX2E 32i NX7E Battery Box to the SL1000 system 2 2 Unpacking Unpack the IP4WW Battery Box and check it against the following list Inspect for...

Страница 51: ...equivalent Voltage must be 12 V Recommended Battery GS Yuasa NP7 12 151 x 65 x 97 5 mm 2 7 kg GS Yuasa International LTD The Battery must be UL recognized product Number of Batteries per Box 2 Backup...

Страница 52: ...rews with stopper Figure 2 27 Removing the Front Cover 2 Disconnect the Battery Connection Cable from the Fuse Unit if the cable is plugged already Battery Connection Cable Fuse Unit Figure 2 28 Disco...

Страница 53: ...Batt Stopper Screw Batt Stopper Figure 2 29 Batt Stopper 4 Pull out the Battery tray Battery tray Figure 2 30 Pulling out the Battery Tray 5 Loosen two screws and remove the Battery tray cover ISSUE...

Страница 54: ...Two screws with stopper Battery tray cover Battery tray bracket Figure 2 31 Remove the Battery Tray Bracket 7 Install two batteries into the Battery tray Two screws M3 X 8 Two batteries Battery tray b...

Страница 55: ...Cable into the Cable guides as shown in the next diagram 10 Install the Battery tray cover aligning the three tabs and tightening the two screws Two screws with stopper Three tabs Battery tray cover B...

Страница 56: ...nto the Battery Box Battery tray Figure 2 35 Inserting the Battery Tray 12 Set the Batt Stopper bracket in place and secure with screw Screw Batt Stopper Figure 2 36 Secure Batt Stopper Bracket SL1000...

Страница 57: ...C D E F c d e f Front cover Two screws with stopper Figure 2 38 Installation of Front Cover 2 6 Mounting the IP4WW Battery Box The IP4WW Battery Box can be installed on either the floor or wall One K...

Страница 58: ...hor bolts locally procured Mark and drill the four holes required to install the FM WM Base 3 Using anchor bolts secure the FM WM Base to the floor Four Anchor bolts M10 mm 0 394 Front side Front side...

Страница 59: ...Screws M4 X 8 IP4WW Battery Box FM WM Base FM WM Base Figure 2 42 Securing the Battery Box 2 6 2 Wall Mounting the IP4WW Battery Box When wall mounting the IP4WW Battery Box ensure the wall can suppo...

Страница 60: ...crews secure the WM Support to the FM WM Base F and Base R Four Screws M4 X 8 WM Support FM WM Base R FM WM Base F Figure 2 43 Assemble Battery Box Base 2 Refer to Figure 2 44 Wall Mount Spacing Guide...

Страница 61: ...Anchor bolt location Anchor bolt location Four Anchor bolts M10 mm 0 394 150 mm 5 906 343 mm 13 504 500 mm 19 685 460 mm 18 110 460 mm 18 110 Front side Front side Wall AC inlet side AC inlet side Fi...

Страница 62: ...with stopper Figure 2 45 Removing the Front Cover 5 Using the four hooks on the FM WM Base mount the IP4WW Battery Box to the Base IP4WW Battery Box Square hole Hooks Hooks A B C D A a b c d B C D Fi...

Страница 63: ...47 Securing the Battery Box 2 6 3 Mounting One KSU on the Battery Box Before wall mounting or floor mounting the IP4WW Battery Box a single KSU can be mounted on the Battery Box 1 Loosen two screws an...

Страница 64: ...at the upper FACE as shown in Figure 2 49 Removing the L Bracket on page 2 34 is located at the bottom as shown in Figure 2 50 Securing the L Bracket and WM Hook on page 2 35 4 Insert tabs on Battery...

Страница 65: ...ws M4 X 8 Anchor Bolts L Bracket WM Hook Figure 2 50 Securing the L Bracket and WM Hook 7 Install four screws into the L Bracket Do not tighten A space of 2 5 mm 0 098 to 3 5 mm 0 138 for KSU mounting...

Страница 66: ...all the Topaz Battery Box DX2E 32i NX7E Battery Box to the SL1000 system Make sure the system power is off If Expansion KSU s are installed turn the power on off in the order of Expansion 3 KSU Expans...

Страница 67: ...ausing the fuse to blow before replacing the fuse otherwise you may cause fire or electrical hazards Be sure to use only the specified fuse 250VT8AL Be sure to install the fuse into the correct locati...

Страница 68: ...Cover Two screws with stopper Figure 2 55 Removing the Front Cover 3 Disconnect the Battery connection cable from the Fuse Unit Battery Connection Cable Fuse Unit Figure 2 56 Disconnecting the Battery...

Страница 69: ...Fuse Unit out of the Battery box 6 Replace the fuse 250VT8AL 250VT8AL Fuse Fuse Unit guide Fuse Unit Figure 2 58 Replacing the Fuse 7 Using the Fuse Unit guides slide the Fuse Unit into the Battery B...

Страница 70: ...g the screw Screw Fuse Unit Figure 2 60 Securing the Fuse Unit 9 Reconnect the Battery Connection Cable to the Fuse Unit Battery Connection Cable Fuse Unit Figure 2 61 Connect Battery Connection Cable...

Страница 71: ...s A to F on Battery Box Slide the Front Cover into position and tighten the two screws b a A B C D E F c d e f Front cover Two screws with stopper Figure 2 62 Installation of the Front Cover ISSUE 3 0...

Страница 72: ...not support any trunks The function of IP4WW 000E A1 card is just a mounting card for the 2BRIDB The 2BRIDB C1 can be installed in following combinations Daughter Board Option Unit 408M A1 408E A1 008...

Страница 73: ...E A1 PCBs Set the switches on the 2BRIDB C1 board before mounting it onto the 000E A1 008E A1 PCB 3 3 1 Mounting the 408E A1 008E A1 000E A1 1PRIU C1 PCBs The procedure for mounting the expansion inte...

Страница 74: ...n and Metal spacers are provided with 408E 008E 000E 1PRIU If no more Expansion Interface cards are to be mounted on the 1st PCB fasten two screws to secure the 1st PCB on the top of the 408E 008E 000...

Страница 75: ...1PRIU If no more Expansion interface card is mounted on the 2nd PCB fasten two screws to secure the 2nd PCB to the top of the 408E 008E 000E 1PRIU Expansion Interface Card 2nd PCB J1 J2 Nylon Spacers...

Страница 76: ...op of the 408E 008E 000E 1PRIU Expansion Interface Card 3rd PCB Nylon Spacers Metal Spacers Screws Expansion Interface Card 2nd PCB Screw position Both sides are the same EXP 3rd PCB J1 J2 J2 J2 J1 Fi...

Страница 77: ...3rd PCB Figure 2 69 Plastic Knockouts 9 Replace the Main cover and fasten two screws Two screws Hooks Main Cover Figure 2 70 Replacing the Main cover 3 3 2 Mounting the 2BRIDB PCB Set the switches on...

Страница 78: ...RIDB C1 PCB 3 Mount the 2BRIDB C1 PCB onto the 008E A1 000E A1 PCB using two Nylon spacers and one screw Refer to Figure 2 72 Installing the 2BRIDB C1 on page 2 48 4 Attach the 2BRI Label to the speci...

Страница 79: ...2BRIDB C1 into the KSU 6 Replace the Main Cover and fasten two screws Two screws Hooks Main Cover Figure 2 74 Replacing the Main Cover 3 4 Cabling and Setting the Expansion Interface Card Precautions...

Страница 80: ...it does not work properly 3 4 1 Cabling IP4WW 408E A1 This IP4WW 408E A1 PCB provides four RJ11 connections for analog trunks and eight RJ11 connections for hybrid extensions Before plugging in the Mu...

Страница 81: ...or Modular Jacks from Telecom Multiline Telephone DSS Console SLT Modular Cable 2 wire Straight Figure 2 75 Connectors of 408E A1 Only Analog Telephones can be connected when this PCB is installed as...

Страница 82: ...line Telephone DSS Console SLT Modular Cable 2 wire Straight Figure 2 76 Connectors of 008E A1 Only Analog Telephones can be connected when this PCB is installed as the 3rd PCB in each Main or Expansi...

Страница 83: ...BRI Pin Outs S Bus T Bus Pin No RJ 61 Cable Connec tor 2BRIDB J2 BRI1 J3 BRI2 S Bus Connection RJ 61 Cable Connector 2BRIDB J2 BRI1 J3 BRI2 T Bus Con nection 87654321 1 2 3 RA TA 4 TA RA 5 TB RB 6 RB...

Страница 84: ...the connection type on the system they only add remove the termination of the circuit J13 J14 J16 J17 do not configure the connection type on the system they only select the polarity of the connector...

Страница 85: ...4321 1 TA RA 2 TB RB 3 4 RA TA 5 RB TB 6 7 8 3 4 5 2 Switch Setting The following figure shows the location of the switches and LEDs on the IP4WW 1PRIU C1 Card 1 Set the switches J6 to J9 according to...

Страница 86: ...table Each LED is listed with its associated function and LED and operational status Table 2 14 LED Indication LED Indication Operation Status Remarks Live LED D4 Green Busy LED D3 Red On On System I...

Страница 87: ...arm The LED indication pattern LOS LOS Loss of Signal Red Alarm No Signal Analog Interface Following an alarm blink red green red green a red LED lighting up AIS AIS Alarm Indication Signal Blue Alarm...

Страница 88: ...een red green a red LED and a green LED flash on and off 3 times simultane ously RAI RAI Remote Alarm Indication Yellow Alarm Following an alarm blink red green red green a green LED flashes on and of...

Страница 89: ...r of 408M A1 3 5 2 Power Failure Setting Hardware switch J6 must be set from KT to PF side default KT when use the Power failure transfer circuit 1 Use Needle nose pliers to change the switch position...

Страница 90: ...e from 8 to 16 channels This daughter board is mounted on the CPU card and provides the SDRAM and flash memories 4 1 2 Unpacking Table 2 17 MEMDB C1 Packing List Items List of Contents QTY IP4 MEMDB C...

Страница 91: ...Two screws Hooks Main Cover Figure 2 85 Removing the Main Cover 4 Press tab A and lift the CPU support bracket Remove the CPU card CPU support CPU card 408M A1 at 1632M KSU A Figure 2 86 Removing the...

Страница 92: ...e secured to notch A Notch B J4 Notch A Lever CPU card MEMDB C1 PCB Figure 2 87 Installing the MEMDB PCB 6 Reinstall the CPU card into the 408M A1 mother board and close the CPU support making sure th...

Страница 93: ...ay The daughter board is installed on the CPU card 4 2 2 Unpacking Table 2 18 VOIPDB C1 Packing List Items List of Contents QTY IP4WW VOIPDB C1 IP4WW VOIPDB C1 1 Ferrite Core for Ethernet Cable 1 4 2...

Страница 94: ...e Sub Cover Sub Cover Sub Cover Tab Tab Figure 2 90 Removing the Sub Cover 3 Loosen two screws and remove the Main Cover Two screws Hooks Main Cover Figure 2 91 Removing the Main Cover SL1000 ISSUE 3...

Страница 95: ...port CPU card 408M A1 at 1632M KSU A Figure 2 92 Removing the CPU Card 5 Install the VOIPDB C1 daughter board to J5 connector on the CPU card CPU card J5 VOIPDB C1 PCB Nylon Spacers Nylon Spacers Figu...

Страница 96: ...t CPU card 408M A1 at 1632M KSU Figure 2 94 Installing the CPU Card 7 Cut and remove the Plastic Knockout for VoIP connector then replace the Main Cover and fasten two screws Two screws Main Cover Pla...

Страница 97: ...the SL Programming Manual for detailed programming instructions The VoIP feature requires system configuration For the details of setting and operation refer to the SL Features Specifications Manual...

Страница 98: ...mission Not support Please change HUB etc to full duplex transmission Flash Blinking one by one The firmware is being updated 4 3 VRS Voice Mail Card PZ VM21 4 3 1 General The PZ VM21 daughter board p...

Страница 99: ...Sub Cover Sub Cover Sub Cover Tab Tab Figure 2 98 Removing the Sub Cover 3 Loosen two screws and remove the Main Cover Two screws Hooks Main Cover Figure 2 99 Removing the Main Cover ISSUE 3 0 SL1000...

Страница 100: ...408M A1 at 1632M KSU A Figure 2 100 Removing the CPU Card 5 Connect the PZ VM21 daughter board to the J6 connector using four Nylon spacers on the CPU card CPU card J6 PZ VM21 PCB CN1 Nylon spacers N...

Страница 101: ...Cover 4 4 Installing the CF Card CFVRS CFVMS CFVML Do not remove or install the CPU Card with the power on If Expansion KSU s are installed turn the power on off in the order of Expansion 3 KSU Expan...

Страница 102: ...ard into the CF slot CN2 CF card CF Slot CN2 CPU card PZ VM21 PCB Figure 2 104 Installing the CF Card 3 Reinstall the CPU card into the 408M A1 mother board and close the CPU Support making sure tab A...

Страница 103: ...ator Help Programmable function keys 24T XH only Dial keys Hold Speaker Speaker Flash Transfer DND CONF 12TXH 24TXH DND 24TIXH Mute Clear Back Cursor control key Light Sensor 24TIXH Soft key 24TIXH Fi...

Страница 104: ...line Telephone provides adjustable legs for angling the phone to best suit each user The leg can be set for two different heights Low High 5 1 2 1 Low Position Setting 1 Turn telephone over button sid...

Страница 105: ...per Figure 2 108 Setting for High Position 3 Adjust the leg to desired height Leg High position Figure 2 109 Leg Setting for High Position 4 Lead the Line and Handset cords through the applicable groo...

Страница 106: ...phone line cord Handset cord Figure 2 110 Cabling for Wall Mount For IP4WW 24TIXH C only V1 2 Added When wall mounting the IP4WW 24TIXH C attach the IP4WW WALL MOUNT UNIT to the bottom panel as shown...

Страница 107: ...hanger Figure 2 112 Hook Switch Hanger 3 Install two screws into a wall The screw heads must be remained about 3 mm 0 12 7 9 5 mm 0 28 0 37 83 5 mm 3 287 Minimum 10 mm 0 39 3 4 mm 0 12 0 16 1 3 mm 0...

Страница 108: ...8 9 0 Mute DND Transfer Figure 2 115 IP Multiline Telephone Connection 5 2 2 Installing the IP Multiline Telephone 1 Connect the LAN Network 10Base T 100Base TX cable to the LAN connector 2 If the Po...

Страница 109: ...r source to a requesting end device 5 3 Installing the DSS Console The 60D DSS A Console can be installed on the last hybrid extension ports ST8 ST16 ST24 of each 408M A1 408E A1 008M A1 card directly...

Страница 110: ...applicable grooves Figure 2 118 Cabling of DSS 5 3 1 2 High position setting 1 Turn DSS Console over button side down 2 Pull up the Leg Stoppers Leg Stopper Figure 2 119 Leg Stopper of DSS Console SL...

Страница 111: ...ooves Refer to Figure 2 118 Cabling of DSS on page 2 80 5 3 2 Wall Mounting the DSS Console 1 Lift the leg and lead the cable through the applicable grooves Refer to Figure 2 121 Cabling for Wall Moun...

Страница 112: ...ounting holes Wall side Figure 2 123 Mounting the DSS 5 4 Installing the Headset The Multiline Telephone user can utilize a customer provided headset in place of the handset Like using Handsfree using...

Страница 113: ...Socket Recommended Headset HW251N A10 NE This Item is made by Plantronics inc For the details of setting and operation refer to the SL1000 Feature Specifications Manual separate issue The headset conf...

Страница 114: ...ble Wall mount bracket Screw terminals Figure 2 126 Doorphone Box and Bracket 4 Mount the Wall Mount bracket on the wall using supplied screws 5 Replace the Upper housing and tighten the screw Upper h...

Страница 115: ...using system programming The 3rd party Doorphone Boxes cannot be connected to the port 5 5 3 Doorphone Interface Specifications Table 2 23 Doorphone Interface Specifications Item Specification Output...

Страница 116: ...nector Table 2 24 RJ 61 General Purpose Door Unlock Relay Control Connector J7 Pin No Connection 87654321 RY1 2 J7 1 2 3 Relay 2 4 Relay 1 5 Relay 1 6 Relay 2 7 8 Table 2 25 General Purpose Door Unloc...

Страница 117: ...and BGM can be set for the 408M A1 PCB of the Main KSU only Wire position for each port Trunk port position CO2 or Audio in out External paging CO3 or Audio in External MOH CO4 or Audio in BGM CO1 CO2...

Страница 118: ...ge Detail Recording 5 8 1 General SMDR Station Message Detail Recording provides a record of the system s outside calls Typically the record outputs to a customer provided SMDR device such as PC via L...

Страница 119: ...out the Lithium battery protection sheet before starting up the system Lithium battery protection sheet Figure 3 1 Lithium Battery Protection Sheet If Expansion KSU s are installed turn the power on o...

Страница 120: ...r of Expansion 3 KSU Expansion 2 KSU Expansion 1 KSU and then Main KSU To perform a Cold Start 1 Set the power switch to off position Figure 3 2 Power Switch Location 2 Open the Sub Cover on the Main...

Страница 121: ...ction describes how to load system software from flash memory and the customer data from RAM memory System software is loaded from flash memory and the customer data is loaded from RAM memory If Expan...

Страница 122: ...ssue 2 2 Exiting the Programming Mode 1 Press Mute key several times to return to the Program Mode Screen 10 01 Sys Time Data Setup Program Mode Figure 3 8 Exiting the Programming Mode Display 1 2 Pre...

Страница 123: ...data backup to the CF card is completed the display will be changed to the next PRG 90 03 01 SavingSystemData 90 04 M tenanc Load Data Figure 3 12 PRG90 04 Display 5 Remove the CF Card and exit from t...

Страница 124: ...ter the Program Mode then PRG90 04 Program Mode 90 04 01 Data Load Figure 3 14 PRG90 04 Display 3 Dial 1 and press Hold key 4 When the data backup to the CF card is completed the display changes to th...

Страница 125: ...KSU DO NOT power off by disconnecting the AC or DC for battery backup power Always use the Power Switch on the Main Expansion KSU All calls in progress will be cut off when the system is powered off a...

Страница 126: ...MEMO SL1000 ISSUE 3 0 3 8 System Start Up...

Страница 127: ...power to the system If Expansion KSU s are installed turn the power on off in the order of Expansion 3 KSU Expansion 2 KSU Expansion 1 KSU and then Main KSU 1 Turn off the system power and disconnect...

Страница 128: ...emove the Main Cover Two screws Hooks Main Cover Figure 4 2 Removing the Main Cover 4 Exchange the fuse 250 V 8 A on 408M A1 PCB Top View 408M A1 FUSE 8 A 250 V Figure 4 3 Exchanging the Fuse SL1000 I...

Страница 129: ...5 Replace the Main Cover and fasten two screws Two screws Hooks Main Cover Figure 4 4 Replacing the Main Cover ISSUE 3 0 SL1000 Hardware Manual 4 3...

Страница 130: ...ion Before replacing the Lithium battery make sure which type of Lithium battery is required and prepare the new Lithium battery CR2032 NEC recommends that a backup of the customer data is performed b...

Страница 131: ...ng the Sub Cover 2 Power off the system and remove the AC plug from the AC outlet 3 Disconnect the AC power cord from the KSU AC power cord must be disconnected otherwise the Main Cover cannot be open...

Страница 132: ...crews Hooks Main Cover Figure 4 8 Removing the Main Cover 5 Press tab A and lift the CPU support bracket 6 Remove CPU card from the Main KSU CPU support CPU card 408M A1 at 1632M KSU A Figure 4 9 Remo...

Страница 133: ...ion of Lithium Battery Socket 8 Remove the old Lithium battery and insert the new one into the socket The polarity symbol must be on top as illustrated in following figure Lithium battery Socket Figur...

Страница 134: ...card into the 408M A1 mother board and close the CPU support bracket CPU support CPU card 408M A1 at 1632M KSU Figure 4 13 Installing the CPU Card 10 Replace the Main Cover and Sub Cover SL1000 ISSUE...

Страница 135: ...d store the new main software on the CF card by PC New main system software is supplied by NEC Install the PZ VM21 PCB if the system does not have it 3 3 Main Software Version Confirmation The Main so...

Страница 136: ...on 2 KSU Expansion 1 KSU and then Main KSU 1 Power off the system and disconnect the AC cord from the KSU 2 Remove the Sub Cover Sub Cover Tab Tab Figure 4 15 Removing the Sub Cover 3 Loosen two screw...

Страница 137: ...n the CPU card Sub Cover Tab Front view S1 LOAD CPU card Tab Figure 4 18 LOAD Button S1 Location 6 Turn the system power on 7 Continue holding the LOAD button S1 for approximately 10 seconds or until...

Страница 138: ...back on 13 When the system has completed reloading the software the RUN LED D1 will flash blue To confirm the new software version number press the Navigation key on any display telephone to view the...

Страница 139: ...linking Off System Starting Up On Off Off Off Off Boot is starting On Off Off Off Blinking Initializing the disk or formatting Blinking Off Off Off Off Reading System Program Blinking Off On Access Bl...

Страница 140: ...MEMO SL1000 ISSUE 3 0 4 14 Maintenance...

Страница 141: ...408Mx2 PRIx2 408Ex4 3 4KSU 408Mx3 PRIx3 408Ex6 Trunk Port Analog Trunks COT 16 32 48 48 1KSU 408M 408Ex3 2KSU 408M 408Ex3 x2 3 4KSU 408M 408Ex3 x3 BRI 12 24 36 36 1KSU 2BRIx3 on 008E 000E 2KSU 2BRIx6...

Страница 142: ...DB CFVMS C1 Port increased by license 4 VM ports 4 VRS ports default Total Max 8 w o MEMDB or 16 w MEMDB CFVML C1 Port increased by license Virtual Extension 50 Relay 2 4 6 8 2 circuits on 408M Power...

Страница 143: ...it Operating Conditions KSU PCBs and Multiline Telephones Temperature 0 to 40 degree C 32 to 104 degree F Humidity 10 to 90 non condensing Doorphone Box Temperature 20 to 60 degree C 4 to 140 degree F...

Страница 144: ...KSU 597 BTU 4 KSU Total 2388 BTU Main KSU 597 BTU 4 KSU Total 2388 BTU 2 6 Electrical Specifications Power Supply KSU Table 5 4 Electrical Specifications of KSU Item Specification Output Voltage 27 V...

Страница 145: ...Weight Note 1632M A KSU 1632ME A EXP 375 mm 14 76 in 115 mm 4 53 in 290 mm 11 42 in Approx 2 kg 70 55 oz External Backup Battery 500 mm 19 69 in 230 mm 90 55 in 340 mm 13 39 in 10 3 kg excluding batt...

Страница 146: ...CFVRS C1 43 mm 1 69 in 37 mm 1 46 in 3 5 mm 0 14 in 0 01 kg 0 35 oz IP4WW CFVMS C1 43 mm 1 69 in 37 mm 1 46 in 3 5 mm 0 14 in 0 01 kg 0 35 oz IP4WW CFVML C1 43 mm 1 69 in 37 mm 1 46 in 3 5 mm 0 14 in...

Страница 147: ...tions Table 5 14 CPU Card LAN Port Specifications Item Specification Standard IEEE802 3 10Base T and 100Base TX Compliant Access CSMA CD I F Layer 1 Speed 10 Mbps 100 Mbps Auto Negotiation Cable CAT5...

Страница 148: ...log Terminals 20mA 24 AWG 0 5 mm 1 125 m 3 691ft Doorphone Box 24 AWG 0 5 mm 150 m 492 1 ft CPU LAN Port to External Device Ethernet Cross Cable 100 m 328 1 ft CPU LAN Port to Switching Hub Ethernet S...

Страница 149: ...MEMO ISSUE 3 0 SL1000 Hardware Manual 5 9...

Страница 150: ...Hardware Manual NEC Corporation ISSUE 3 0...

Отзывы: