Installation
S
ECTION
1 INSTALLING THE MAIN & EXPANSION KSU
S
1.1 Before Installing the KSU(s)
1.1.1 General Precautions
• To avoid shock or equipment damage, do not plug in or turn the system power on before completing
the installation process.
• Avoid working with the Equipment during electrical storms.
• Use only commercial AC power to prevent shock or fire.
• Use the power cord supplied with the KSU.
• Install batteries with the correct polarity to prevent damaging equipment.
• Never install telephone wiring during a lightning storm.
• Never install telephone jacks in wet locations unless the jack is specifically designed for wet
locations.
• Never touch uninsulated telephone wires or terminals unless the telephone line is disconnected at
the network interface.
• To avoid damage, the KSU should not be placed on unstable surfaces.
• To prevent overheating, do not bundle AC power cords together.
• Make sure the KSU has proper Earth ground.
• If Expansion KSU(s) are installed, turn the power on/off in the following order: Expansion 3 KSU,
Expansion 2 KSU, Expansion 1 KSU and then Main KSU
1.1.2 Preparations
• Make sure the necessary tools (screw driver set, pliers set, etc) are available.
• Make sure you have a building plan showing common equipment, extensions, the telecom
demarcation, and earth ground location. The installation site must meet the following site /
environmental requirements.
1.1.3 Site Requirements
Each Main or Expansion KSU(s) can have the optional Battery Box connected, before deciding on the
mounting location refer to
Figure 2-4 Horizontal Arrangement of the KSUs on page 2-6
and
INSTALLING THE EXTERNAL BACKUP BATTERY on page 2-20
.
• The system without the IP4WW-Battery Box should be wall-mounted only. The system with the
IP4WW-Battery Box can be installed on either the floor or wall (horizontally). Ensure enough space
exists to allow the installation of additional KSU(s) and/or battery box.
• A dedicated 100V-120V/220V/230V/240VAC circuit located within two meters of the KSU is
required. A separate dedicated AC outlet is necessary for each KSU.
Hardware Manual
2-1
Installation
2
Содержание SL1000
Страница 1: ...Hardware Manual A50 031170 001 GE ISSUE 3 0 November 2012...
Страница 12: ...MEMO SL1000 ISSUE 3 0 x Hardware Manual...
Страница 16: ...MEMO SL1000 ISSUE 3 0 R 4 Regulatory...
Страница 126: ...MEMO SL1000 ISSUE 3 0 3 8 System Start Up...
Страница 140: ...MEMO SL1000 ISSUE 3 0 4 14 Maintenance...
Страница 149: ...MEMO ISSUE 3 0 SL1000 Hardware Manual 5 9...
Страница 150: ...Hardware Manual NEC Corporation ISSUE 3 0...