B-8 System Board Settings
5.
Replace the system unit cover (see “Replacing the System Unit Cover” in
Section 3).
6.
Connect system power cables and monitor.
7.
Power on the system. The system displays a system configuration error message.
8.
Power off, unplug the system and monitor, and remove the cover.
9.
Remove the jumper block from pins 26-28 and replace it on pins 28-30.
10.
If you removed any expansion boards, replace them (see “Expansion Board
Installation” in Section 3).
11.
Replace the system unit cover. Reconnect the system power cables and
peripheral devices.
12.
Power on the system.
13.
Run Setup (see Section 2).
Password Clear Jumper
Use the following procedure to clear the current password and to set a new one. This
procedure should only be done if the user password has been forgotten.
1.
Turn off and unplug the system and any external options.
WARNING:
The system power must be off
before removing the cover and changing a
jumper setting.
2.
Remove the system unit cover (see “Removing the System Unit Cover” in Section
3).
3.
Locate the Password Clear jumper pins on the system board (see Figure Appendix
B-10).
You may have to remove any installed expansion boards to access the jumpers
(see “Expansion Board Removal” in Section 3).
4.
Remove the jumper block from pins 27-29 and set it on pins 25-27.
Содержание POWERMATE PRO2180 - SERVICE 1996
Страница 140: ...4 14 Maintenance and Troubleshooting ...