General Description
The following explains connectivity issues between a NEAX2400 IPX and a NEAX2000 IVS
2
. An FCCS Group
consists of a network where multiple NEAX2400 IPXs are connected via FCCS link.
Note:
NEAX2400 IPX - NEAX2000 IVS
2
connection is available only if the NEAX2000 IVS
2
is the satellite office
(requires NEAX2000 IVS
2
Series 2000 or later software).
Service Conditions
Network Configuration
1.
The following table shows the summary of network configurations:
Note:
For details, refer to the following services:
Maintenance - Centralized System Management Report - CCIS [C-57]
Billing - Centralized Billing - CCIS [C-55]
MCI - Message Center Interface - CCIS [M-67]
2.
There are two connection types for the network:
a.) NEAX2000 IVS
2
- NEAX2400 IPX connection
b.) NEAX2400 IPX - NEAX2400 IPX connection
Network Establishment
•
NEAX2000 IVS
2
- NEAX2400 IPX
1.
Additional NEAX2000 IVS
2
s cannot be connected to a NEAX2000 IVS
2
that has already been connected
with NEAX2400 IPX. Only one SPAN is allowed for NEAX2400 IPX - NEAX2000 IVS
2
connection.
2.
The maximum number of routes and nodes for the NEAX2000 IVS
2
are given by subtracting the number
of routes (LGRT) used for the NEAX2400 IPX from 899 (maximum number of routes in an FCCS group).
Note:
This condition is applied to the NEAX2400 IPX side. The NEAX2000 IVS
2
system may accommodate up to
255 nodes (including NEAX2400 IPX), because the maximum number of Point Codes (PCs) assigned at
NEAX2000 IVS
2
system is 255, including the nodes in the network.
3.
When the signal route is deleted, the voice route is used per route, but the signal route can be shared with
multiple routes. However, when the network is established using EVENT BASED-CCIS, the signal route
must be used per route.
•
NEAX2400 IPX - NEAX2400 IPX
1.
The maximum number of NIDs per FCCS group is 253.
2.
The maximum number of routes assigned in each FCCS group is 899.
3.
An NCN and NDM exist in each FCCS group.
TYPE
CONNECTION TYPE
MAXIMUM
TELEPHONE
NUMBERS
SERVICE
CENTRALIZED FUNCTION
NEAX2400
IPX -
NEAX2400
IPX
NEAX2000
IVS
2
-
NEAX2400
IPX
NEAX2400
IPX -
NEAX2400
IPX
NEAX2000
IVS
2
-
NEAX2400
IPX
MAINTENANCE
BILLING
Note
MCI
Note
1
FCCS
CCIS
120,000
FCCS
service
CCIS
service
Available
Available
Available
2
CCIS
CCIS
120,000
CCIS service
CCIS
service
Available
Available
Available
Содержание NEAX2400 ICS
Страница 1: ...OCTOBER 2000 NEC America Inc NDA 24297 ISSUE 1 STOCK 200775 Feature Programming Manual ...
Страница 43: ...NEAX2400 IPX Feature Programming Manual Page xxvi NDA 24297 Issue 1 This page is for your notes ...
Страница 690: ...NEAX2400 IPX Feature Programming Manual NDA 24297 Issue 1 Page 647 Splitting S 4 Programming No programming is required ...
Страница 1089: ...NEAX2400 IPX Feature Programming Manual Page 1046 NDA 24297 Issue 1 This page is for your notes ...