NEAX2400 IPX Feature Programming Manual
Page 700
NDA-24297, Issue 1
S-24D
Save And Repeat - D
term
S-24D
Save And Repeat - D
term
General Description
This feature allows for a D
term
set to save a specific dialed number and then redial that number later.
Operating Procedure
1.
Go off-hook, seize any idle line, and dial a number.
2.
When the number has been dialed, press the SAVE AND REPEAT (S&R) feature key. The dialed number
is stored for future use. The associated LED lights. The LCD displays:
Note:
Dialed number displays only 16 digits (16DC, 24DS) when monitoring. However, 24 digits can actually be
stored in memory.
3.
To access this number later, go off-hook, receive dial tone, and press the S&R key; the saved number is
dialed.
Service Conditions
1.
One number per station can be saved.
2.
The save function may be set at any time after the number has been dialed and before going on-hook.
3.
It is not necessary to erase a saved number in order to save another. The second number replaces the first.
4.
A D
term
user may save the number of an incoming call, if the call originates at a station in the system. A
call from an outside trunk cannot be saved.
5.
If necessary, dialing can be added after a repeat operation.
6.
To monitor the saved digits, press the S&R key while idle. The saved digits will be displayed on the LCD.
7.
If the LED associated with S&R goes out, the memory is erased. The S&R key must be pressed again,
using the above procedure, to retain the original memory.
8.
To memorize the telephone number of the calling station, assign SYS1, Index 641, b0=1 (Telephone
Number is available) by the ASYDL command.
9.
When activating this feature via FCCS using a D
term
Series E, the following circuit cards are
recommended:
Note:
If the above mentioned card is not used, the Caller ID Service is not provided and the telephone number and
more than six digits of the calling station number cannot be saved.
10.
When activating this feature via FCCS, the calling number from an outside trunk can be saved, when the
calling number information was received.
FUNCTION NAME
CIRCUIT CARD
16ELC
PA-16ELCJ
DAI
PA-DAIG, PA-DAIH, PA-DAIJ
2DAI
PA-2DAIK
S&R
(Time Display)
9-NXX-XXXX
Example: Saved Local Number
Содержание NEAX2400 ICS
Страница 1: ...OCTOBER 2000 NEC America Inc NDA 24297 ISSUE 1 STOCK 200775 Feature Programming Manual ...
Страница 43: ...NEAX2400 IPX Feature Programming Manual Page xxvi NDA 24297 Issue 1 This page is for your notes ...
Страница 690: ...NEAX2400 IPX Feature Programming Manual NDA 24297 Issue 1 Page 647 Splitting S 4 Programming No programming is required ...
Страница 1089: ...NEAX2400 IPX Feature Programming Manual Page 1046 NDA 24297 Issue 1 This page is for your notes ...