NEAX2400 IMX Hotel Features and Specifications
Page 60
NDA-24245, Issue 2
D-15
Day/Night Class of Service
D-15
Day/Night Class of Service
General Description
This feature permits all stations within a tenant to alternate between two different CLASS OF SERVICE –
INDIVIDUAL [C-15] options, one for Day mode and another for Night mode. System data can be programmed so
that once the ATTENDANT CONSOLE [A-3] has entered the NIGHT CONNECTION [N-1, 2] mode, a station's
CLASS OF SERVICE – INDIVIDUAL [C-15] will be automatically changed as required. Class may be upgraded
or downgraded, and trunk groups normally controlled by the Console in Day mode may be opened to station control
in Night mode.
For hotel software, DAY/NIGHT Route Restriction Class change may be controlled using Time Of Day
programming via the MAT. The Console will operate in Day mode, but stations will operate under Night mode
restriction tables.
Operating Procedure
1.
This feature is controlled via the ATTENDANT CONSOLE [A-3]. Pressing the NITE key or removing
the handset enters the tenant/system into Night mode and changes service class. Releasing the NITE key
or replacing the handset restores normal CLASS OF SERVICE – INDIVIDUAL [C-15].
2.
If the Time Of Day change is used once programming is set via the MAT, no further operation is required.
Service Conditions
1.
DAY/NIGHT CLASS OF SERVICE can be assigned on a per TENANT [T-12] and per station basis.
2.
DAY/NIGHT CLASS OF SERVICE can be assigned to different trunk restriction and service restriction.
3.
Refer to CLASS OF SERVICE – INDIVIDUAL [C-15] for further details.
4.
Night mode restriction class can be set at any time by entering the related command on the
MAINTENANCE ADMINISTRATION TERMINAL (MAT) [M-18].
5.
When TENANT SERVICE [T-12] is provided with MULTIPLE CONSOLE OPERATION [M-4], the
system can be programmed for either “all attendant consoles” or “master attendant console” to control
activation of DAY/NIGHT CLASS OF SERVICE.
6.
For Service and Tenant Restriction Class changes, the Console must be placed into the Night mode.
7.
This service feature allows transfer of an incoming call to a different destination during either day or night.
Transfer and connection to the different destination is determined by the business hours of the respective
guest service station and the special number assigned to the group number in the night function.
Содержание NEAX2400 ICS
Страница 1: ...NDA 24245 ISSUE 2 STOCK 200890 Hotel Features and Specifications MAY 2000 NECAmerica Inc...
Страница 12: ...NEAX2400 IMX Hotel Features and Specifications Page viii NDA 24245 Issue 2 This page is for your notes...
Страница 14: ...NEAX2400 IMX Hotel Features and Specifications Page 2 NDA 24245 Issue 2 This page is for your notes...
Страница 26: ...NEAX2400 IMX Hotel Features and Specifications Page 14 NDA 24245 Issue 2 This page is for your notes...