NEAX2400 IMX Hotel Features and Specifications
NDA-24245, Issue 2
Page 141
Voice Mail Service Via Message Center Interface (MCI)
V-16
V-16 Voice Mail Service Via Message Center Interface
(MCI)
General Description
Voice mail service is available for guest and Administration Stations through the Message Center Interface (MCI)
in the NEAX2400 IMX Hotel System. This capability allows the integration of a customer-provided voice mail
system, using an RS-232C interface. Guest calls are Call Forwarded – All Calls/Busy/Don't Answer to a UCD
station port group, providing access to the voice mail system. When a voice message is received, the guest station
message waiting lamp lights. When the guest retrieves all his messages, the lamp is turned off.
Operating Procedure
•
To send a message without operator assistance:
•
To retrieve a message without operator assistance:
•
To send a message with operator assistance (attendant only):
Step
Action
Result
1
The guest or Administration Station sets Call
Forwarding – All Calls/Busy Line/Don't Answer.
2
The Administration Station or another guest station
calls guest station.
If guest station is busy or does not answer, the
call is forwarded to Voice Mail.
3
The caller leaves a message in Voice Mail.
4
Notification from Voice Mail, by MW-On
command, is sent to the guest station via MCI.
Guest station's message waiting lamp is lit.
Step
Action
Result
1
The guest station accesses Voice Mail.
2
Message is retrieved.
3
When all the messages have been retrieved,
notification from Voice Mail, by MW-Off
command, is sent to the NEAX2400 IMX via MCI.
Guest station's message waiting lamp is turned
off.
Step
Action
Result
1
A call comes to the Attendant from a station or
trunk.
2
The attendant answers the call.
3
The attendant dials the guest station.
If the station is busy, reorder tone is heard (when
guest station doesn't answer, it becomes a
Recall).
4
The attendant accesses Voice Mail.
A message is left in Voice Mail.
5
Notification from Voice Mail, by MW-On
command, is sent to the NEAX2400 IMX via MCI.
Guest station's message waiting lamp is lit.
Содержание NEAX2400 ICS
Страница 1: ...NDA 24245 ISSUE 2 STOCK 200890 Hotel Features and Specifications MAY 2000 NECAmerica Inc...
Страница 12: ...NEAX2400 IMX Hotel Features and Specifications Page viii NDA 24245 Issue 2 This page is for your notes...
Страница 14: ...NEAX2400 IMX Hotel Features and Specifications Page 2 NDA 24245 Issue 2 This page is for your notes...
Страница 26: ...NEAX2400 IMX Hotel Features and Specifications Page 14 NDA 24245 Issue 2 This page is for your notes...