NEAX2400 IMX Hotel Features and Specifications
Page 12
NDA-24245, Issue 2
NUMBERING PLAN
Examples of Numbering Plan Data Assignments (cont’d)
AGSP
ASPS
With respect to the Access Code (ACC) assign service features
as follows:
ACC
SRV
SID
No.
KIND
0
SSC
57
0
0
8
SSC
56
0
–
ACC
SRV
RT
9
OGC
1
With respect to the data assigned by AASP and AGSP, assign
service features as follows:
No.
F
SRV
SID
STN
0
0
SSC
2
–
0
1
STN
–
4000
Assign the station data of Administration stations. Also, assign
the data for floor service as follows:
STN
ROOM CLASS
“3000” ~ “3500”
0
“4000”
0
“5000”
1 – 7
“5001”
1 – 7
Assign the station data of Guest stations.
(STN “100” – “1000”, STN “200” – “2000”)
Assign the data related to the Room Service.
Station on each floor as follows:
No.
ANX
G
FLR
DC
0
0
0
1
5000
0
0
0
2
5001
AAST
AGST
ASPF
END