CHAPTER 3 SYSTEM DATA PROGRAMMING
– 117 –
ND-71503(E) Rev.5.0
9pch3001.fm
Remote PIM over IP Feature Programming
Remote PIM over IP Link Down Notice Assignment
[Series 3200 R6.2 software required]
When the main site and remote site are disconnected due to a fault occurrence, the link down can be noti-
fied to the D
term
s/D
term
IPs that are connected to the both sites.
To provide the link down notice with the D
term
s/D
term
IPs, in addition to the programming of “Survival
Mode Assignment”, do the following programming.
DESCRIPTION
DATA
Assign the Event Occurrence Notice button to
the D
term
s/D
term
IPs.
NOTE:
Assign this data only to the station
number of D
term
/D
term
IP that the
link down is notified.
•
(1)
(2)
Y=00
My Line No. +
+ Key No.
F1364-F1399: Event Occurrence Notice
button No. 01-36
NONE : No data
Specify the start time to notify the link down to
the D
term
/D
term
IP
after the disconnection be-
tween main site and remote site is detected.
NOTE:
Assign the shorter time than the time
for automatic changeover to surviv-
al mode assigned by CM0B Y=31-
60>50.
If the longer time is set, the link
down cannot be notified.
•
(1)
(2)
Y=31-60 (Remote Site No. 01-30)
52
00: Not notify the link down
01-99: 0-2970 seconds
(30 second increments)
If no data is set, the default setting is 30-60
seconds.
Assign the link down notice for Remote PIM
over IP to the Event Occurrence Notice button.
•
(1)
(2)
Y=0
XX ZZ
XX: 01-36: Event Occurrence Notice but-
ton No.
ZZ : 01-30: Remote Site No. to be notified
0 : To notify
1 : Not notified
START
CM90
,
CM0B
INITIAL
CM9B
END
JANUARY/16/2004
REMOTE PIM OVER IP DATA ASSIGNMENT
CÔNG TY VIỄN THÔNG VIỆT PRO
Chuyên phân phối tổng đài NEC
http://vietpro.com.vn