CHAPTER 3 SYSTEM DATA PROGRAMMING
– 102 –
ND-71503(E) Rev.5.0
9pch3001.fm
Remote PIM over IP LAN Data Assignment
(1) LAN Data Assignment for Main Site
In addition to the programming
(
DESCRIPTION
DATA
Assign the common port number of Device
Handler Manager (DHM) Self port which is
the communication port between the main site
and remote sites, if required.
[Series 3200 R6.2 software required]
NOTE 1:
Follow the initial data setting usual-
ly.
NOTE 2:
The DHM self port is the communi-
cation port between main site and
remote site. One port is used to com-
municate with one remote site.
With this command, the common
port of DHM self port is specified.
And the following DHM self port is
automatically assigned to each re-
mote site.
Port No. for each remote site
=Common Port (Setting Data) +
Remote Site No.
•
(1)
(2)
Y=10
70
01024-65534: DHM Self Port No. 1024-
65534
NONE
: DHM Self Port No. 3300
START
CM0B
INITIAL
END
JANUARY/31/2003
REMOTE PIM OVER IP DATA ASSIGNMENT
CÔNG TY VIỄN THÔNG VIỆT PRO
Chuyên phân phối tổng đài NEC
http://vietpro.com.vn