ND-70348 (E)
CHAPTER 4
Page 214
Revision 3.0
ASYDL
Note 1:
When ASYDL SYS1 INDEX833 b0=0 (RS-232C interface for MCI) is assigned, either ICS or IMX text for-
mat for MCI output can be selected in b1. When b0=1(LAN interface for MCI) is assigned, b1 data must
be fixed to data “1=IMX format.”
SYSTEM
DATA
TYPE
(SYS)
SYSTEM
DATA
INDEX
(INDEX)
512-1535
DATA
(DATA)
00 – FF
(Hex)
BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1
BIT
1
833
b
0
Inter face type for MCI (Message Center Interface)
0/1 = RS-232C interface/LAN interface
Note 1
b
1
MCI output text format
0/1 = ICS format/IMX format
Note 1
b
2
The way to output the call information of LAN Interface for
MCI (when Max. 2 MCs are normally connected).
0/1 = Dual Output/Single Output
Note:
Valid for software Release 9 or later.
b
3
Output the System Message related to connection down when
the system changeover occurs on LAN Interface for MCI.
0/1 = Invalid/Valid
Note:
Valid for software Release 9 or later.
b
4
~b
7
Not used
834
b
0
0/1 = -/MC0 with LAN interface is used
b
1
0/1 = -/MC1 with LAN interface is used
b
2
~b
7
Not used
835~863
Not used
864
b
0
0/1 = Built-in IP, ACDP is not used/used
b
1
Output the system message when TCP-IP connection is normal-
ly disconnected.
0/1 = Effective/Ineffective
b
2
AGENT ANYWHERE
0/1 = Out of service/In service
Note:
This data is effective only when Multiple ACDP
service is used.
b
3
Multiple ACDP
0/1 = Out of service/In service
b
4
, b
5
Maximum number of SMFN port
00 = 2 port (standard)
01 = 8 port
b
6
FLF error detail indication
0/1 = Out of service/In service
b
7
Not used