ND-70348 (E)
CHAPTER 4
Page 211
Revision 3.0
ASYDL
SYSTEM
DATA
TYPE
(SYS)
SYSTEM
DATA
INDEX
(INDEX)
512-1535
DATA
(DATA)
00 – FF
(Hex)
BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1
BIT
1
704
FPC (Fusion Point Code) of the node to which ATT-CON transfers the Day/Night changeover
information.
FPCs range from 1 to 253 as shown on the table below. Assign data “1 (D/N changeover in-
formation is transferred)” for the corresponding FPC node.
Note:
This data is necessary at the node providing ATT-CON.
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736~799
Not used
INDEX
b
7
b
6
b
5
b
4
b
3
b
2
b
1
b
0
704
7
6
5
4
3
2
1
-
705
15
14
13
12
11
10
9
8
706
23
22
21
20
19
18
17
16
707
31
30
29
28
27
26
25
24
708
39
38
37
36
35
34
33
32
709
47
46
45
44
43
42
41
40
710
55
54
53
52
51
50
49
48
711
63
62
61
60
59
58
57
56
712
71
70
69
68
67
66
65
64
713
79
78
77
76
75
74
73
72
714
87
86
85
84
83
82
81
80
715
95
94
93
92
91
90
89
88
716
103
102
101
100
99
98
97
96
717
111
110
109
108
107
106
105
104
718
119
118
117
116
115
114
113
112
719
127
126
125
124
123
122
121
120
720
135
134
133
132
131
130
129
128
721
143
142
141
140
139
138
137
136
722
151
150
149
148
147
146
145
144
723
159
158
157
156
155
154
153
152
724
167
166
165
164
163
162
161
160
725
175
174
173
172
171
170
169
168
726
183
182
181
180
179
178
177
176
727
191
190
189
188
187
186
185
184
728
199
198
197
196
195
194
193
192
729
207
206
205
204
203
202
201
200
730
215
214
213
212
211
210
209
208
731
223
222
221
220
219
218
217
216
732
231
230
229
228
227
226
225
224
733
239
238
237
236
235
234
233
232
734
247
246
245
244
243
242
241
240
735
-
-
253
252
251
250
249
248