6. Appendix
6-6-2. Chiller unit
Model name
NP-17CU01
Power supply voltage
AC 200 to 240 V 50 Hz,
AC 220 to 240 V 60 Hz single phase
Input current
9.2 A (50 Hz) / 10.3 A (60 Hz)
Power consumption
1610 W (50 Hz) / 2000 W (60 Hz)
Net weight
108 kg
(Does not include coolant weight)
Dimensions
700 mm (W) x 650 mm (D) x 575 mm (H) (Does not include protruding portions, includes foot.)
Environment
Operating temperature: 10 to 35°C
Operating humidity: 10 to 85%
(non-condensing)
Storage temperature: -10 to 50°C
Storage humidity: 10 to 85%
(non-condensing)
Operating altitude: 0 to 3000 m/9800 feet
* Note that these specifications and designs can change without prior notice.
CAUTION
1. This appliance shall not be accessible to the general public.
2. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental
capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the
appliance in a safe way and understand the hazards involved.
3. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without
supervision.
4. This appliance shall be installed in accordance with national wiring regulations.
5. An all-pole disconnection switch having a contact separation of at least 3mm in all poles should be connected in fixed
wiring.
6. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or a similarly qualified person in
order to avoid a hazard.
7. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities,
or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance
by a person responsible for their safety.
8. Children should be supervised to ensure that they do not play with the appliance.
9. Cleaning and user maintenance shall not be made by children without supervision.
10. Disconnect the appliance from its power source during service and when replacing parts.
11. Disconnect the power supply before cleaning and maintenance.
12. This appliance is for indoor use only.
13. This appliance is intended to be used by expert or trained users.
Содержание NC1700L
Страница 10: ...10 Chiller unit NP 17CU01 Label F Gas Label NP 17CU01 ID Label Important Information ...
Страница 71: ...71 6 Appendix 6 5 Outline Drawing 6 5 1 Projector 846 930 725 86 700 590 314 326 84 149 206 Units mm ...
Страница 72: ...72 6 Appendix 6 5 2 Chiller unit NP 17CU01 650 45 70 15 490 700 575 Units mm ...
Страница 85: ... NEC Display Solutions Ltd 2016 Ver 2 2 21 ...