Built-In AIT Auto-Loader Unit 17
Hint
✎
• The cartridges are checked in the order of cartridge number (1 to 4).
• In the LCD, the cartridge number being checked is blinking.
3
Using the backup application, or the button and the LCD on the front of the Built-In AIT Auto-
Loader Unit, select the AIT data cartridges to be used and set them in the read/write drive.
When using the backup application, refer to the instruction manual provided with the applica-
tion. When using the button and the LCD on the front of the driver, refer to “Selecting the AIT
data cartridge” described below.
Selecting the AIT data cartridge
AIT data cartridges set in the magazine can be selected from the backup application on the basic
processing unit.
They can also be selected using the button and the LCD on the front of the Built-In AIT Auto-
Loader Unit.
Select the cartridges as shown below.
Check
✔
• The Built-In AIT Auto-Loader Unit does not function at all by pressing the SELECT button in the
following situations:
-
Within 75 seconds after setting the magazine
-
When “Ready” does not appear in the LCD
-
While the BUSY lamp is blinking
• The Built-In AIT Auto-Loader Unit does not function at all by pressing the ENTER button while
the BUSY lamp is blinking.
1
Press the SELECT button
The AIT data cartridge number appears in the LCD. Every time you press the SELECT button,
the cartridge number is changed.
2
Check the selected cartridge number and press the ENTER button.
The AIT data cartridge preset in the read/write drive is returned to the magazine. The AIT data
cartridge selected in the LCD is then automatically set in the read/write drive.