Built-In AIT Auto-Loader Unit
7
Setting terminator power - Terminator Power -
Set whether terminator power is supplied to the SCSI bus or not.
Use Switch 5. Setting Switch 5 to ON (factory-set to ON) will
supply terminator power; setting Switch 5 to OFF will not supply
terminator power.
* When this unit is installed in the N8541-28F device expansion
unit, set this switch to OFF if you want to use the slaved power
control feature.
Setting data compression - DC Control (1) -
Set whether the Built-In AIT Auto-Loader Unit’s data compression
function is enabled or disabled.
Use Switch 7. Setting Switch 7 to ON (factory-set to ON) will
enable the data compression function; setting Switch 7 to OFF will
disable the terminator data compression function.
Setting data compression - DC Control (2) -
Set whether control of data compression from the backup software
is enabled or disabled.
Use Switch 8. Setting Switch 8 to ON will disable control of data
compression from the backup software; setting Switch 8 to OFF
(factory-set to OFF) will enable control of data compression from
the backup software.
Mounting on the basic processing unit
CAUTION
Before installing this unit, make sure you unplug the power plug for the basic
processing unit you are using (such as a server or workstation basic processing
unit). Leaving the power cord plugged in presents an electrical shock hazard.
Mount the Built-In AIT Auto-Loader Unit on the basic processing unit.
Important
When mounting N8551-29F Built-In AIT Auto-Loader Unit on Express 5800/130/140/150/ 170/180
Pro, do not attach it to the bottom of 5.25-inch device bay.
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON