346
Chapter 10
Timer
Preliminary User’s Manual U15839EE1V0UM00
10.3.9 Edge noise elimination
The edge detection circuit has a noise elimination function. This function regards:
• a pulse not wider than 1 count clock period as a noise, and does not detect it as an edge.
• a pulse not shorter than 2 count clock periods is detected normally as an edge.
• a pulse wider than 1 count clock period but shorter than 2 count clock periods may be
detected as an edge or may be eliminated as noise, depending on the timing.
(This is because the count-up signal of the counter is used for sampling timing.) The upper figure below
shows the timing chart for performing edge detection. The lower figure below shows the timing chart for
not performing edge detection.
Basic settings (x = 0, 1 and y = 0 to 5):
Figure 10-58:
Timing of Edge detection noise elimination
Bit
Value
Remark
CSEx2
0
Count clock = f
PCLK
/4
CSEx1
1
CSEx0
0
IEGy1
1
detection of both edges
IEGy0
1
t+2
t+3
t+4
t+5
t+6
t+7
t+6
t
t+1
t+4
t+2
t+4
t+5
t
t+1
t+3
t+6
t+7
<Timing chart for performing edge detection>
<Timing chart for noise elimination>
TMGn0/TMGn1
TIGny
INTCCGny
GCCny
f
PCLK
f
COUNTx
TMGn0/TMGn1
TIGny
INTCCGny
GCCny
f
PCLK
f
COUNTx
Содержание mPD703128
Страница 6: ...6 Preliminary User s Manual U15839EE1V0UM00 ...
Страница 20: ...20 Preliminary User s Manual U15839EE1V0UM00 ...
Страница 32: ...32 Preliminary User s Manual U15839EE1V0UM00 MEMO ...
Страница 154: ...154 Preliminary User s Manual U15839EE1V0UM00 MEMO ...
Страница 238: ...238 Preliminary User s Manual U15839EE1V0UM00 MEMO ...
Страница 356: ...356 Preliminary User s Manual U15839EE1V0UM00 MEMO ...
Страница 522: ...522 Preliminary User s Manual U15839EE1V0UM00 MEMO ...
Страница 600: ...600 Preliminary User s Manual U15839EE1V0UM00 MEMO ...
Страница 610: ...610 Preliminary User s Manual U15839EE1V0UM00 ...
Страница 612: ......