2.4
Power Supply Settings
Using the JP2 setting, the IE-703102-MC-EM1 can switch between operation using the emulator as a stand-alone
unit (using the power of the emulator) and operation using the emulator connected to the target system (using the
power of the target system).
2.4.1 JP2 setting when the emulator operates as a stand-alone unit and target system power is off
The IE-703102-MS-EM1 operates using the emulator’s power supply when the emulator operates as a stand-
alone unit and target system power is off. Depending on the product, the condition of the power is as follows.
•
IE-703102-MC-EM1
: V
DD
= 3.3 V, HV
DD
= 5.0 V
•
IE-703102-MC-EM1-A : V
DD
= 3.3 V, HV
DD
= 3.3V
Figure 2-2 shows the JP2 setting.
Caution
If the JP2 setting is incorrect, the emulator may be damaged.
Figure 2-2. Power Supply Settings (When the Emulator Operates as a Stand-Alone Unit and
Target System Power is Off)
1
2
3
4
JP2
Set both 1-2 and 3-4 as open
2.4.2 JP2 setting when power of the target system is on
The IE-703102-MC-EM1 operates using the target system’s power supply when the power of the target system is
on. Figure 2-3 shows the JP2 setting.
Caution
If the JP2 setting is incorrect, the emulator may be damaged.
Figure 2-3. Power Supply Setting (When Power of the Target System is On)
1
2
3
4
JP2
Set 1-2 as open and 3-4 as short
Содержание IE-703102-MC-EM1
Страница 2: ...2 MEMO ...
Страница 10: ...10 MEMO ...
Страница 24: ...24 MEMO ...
Страница 26: ...26 MEMO ...
Страница 34: ...34 MEMO ...
Страница 36: ...APPENDIX A DIMENSIONS 36 2 SC 144SD Unit mm 109 144 72 37 108 1 73 36 43 13 13 40 130 43 213 46 ...
Страница 40: ...40 MEMO ...
Страница 46: ...46 MEMO ...
Страница 48: ...48 MEMO ...