NEC Express Server

 

Express5800 Series

 

Express5800/R120f-2E, T120f 
EXP330A, EXP331A, EXP332A 
 
 

Maintenance Guide 

Chapter 1  Maintenance 

 

Chapter 2    Useful Features 

 

Chapter 3  Appendix 

10.110.01-104.01 

December 2014

 

© NEC Corporation 2014 

 
 

Содержание Express5800/R120f-2E

Страница 1: ...Server Express5800 Series Express5800 R120f 2E T120f EXP330A EXP331A EXP332A Maintenance Guide Chapter 1 Maintenance Chapter 2 Useful Features Chapter 3 Appendix 10 110 01 104 01 December 2014 NEC Corporation 2014 ...

Страница 2: ...onal options connection of peripheral devices and suitable location for this server Chapter 3 Setup System BIOS configurations and summary of EXPRESSBUILDER Chapter 4 Appendix Specifications and other information Installation Guide Windows Chapter 1 Installing Windows Installation of Windows and drivers and precautions for installation Chapter 2 Installing Bundled Software Installation of NEC ESMP...

Страница 3: ...tenance 18 2 1 Checking and Applying Updates 18 2 2 Checking Alerts 18 2 3 Checking STATUS LED 19 2 4 Backup 19 2 5 Cleaning 19 2 5 1 Cleaning the server 20 2 5 2 Cleaning the tape drive 20 2 5 3 Cleaning the keyboard and mouse 20 3 User Support 21 3 1 Maintenance Services 21 3 2 Before Asking for Repair 21 4 Collecting Failure Information 22 4 1 Collecting Event Logs 22 4 1 1 Windows Server 2012 ...

Страница 4: ...tting and Clearing the Server 46 7 1 Software Reset 46 7 2 BMC Reset 46 7 3 Forced Shutdown 48 7 4 Clearing BIOS Settings CMOS Memory 49 8 System Diagnostics 52 8 1 Tests 52 8 2 Usage of System Diagnostics 52 9 Offline Tools 55 9 1 Starting Offline Tools 55 9 2 Features of Offline Tools 56 9 3 Console less feature 57 9 3 1 How to remotely control 57 9 3 2 Preparation 57 Chapter 2 Useful Features 5...

Страница 5: ...ETUP 135 5 4 2 Advanced menu 136 5 4 3 Quitting LSI Software RAID Configuration Utility 137 5 5 Menu Tree of UEFI Mode 138 5 6 Procedures for Using Configuration Utility in UEFI Mode 141 5 6 1 Create add configuration 141 5 6 2 Manual Rebuild 157 5 6 3 Configure HotSpare 159 5 6 4 Check Consistency 163 5 6 5 Others 167 5 7 LSI Software RAID Configuration Utility and Universal RAID Utility 168 5 8 ...

Страница 6: ...pendix 185 1 POST Error Message 186 2 List of Windows Event Logs 202 3 Accessing Data for Electric Power Temperature and Processor Utilization 215 3 1 Windows 215 3 1 1 Power consumption 215 3 1 2 Intake air temperature 216 3 1 3 Processor utilization 219 4 Glossary 220 ...

Страница 7: ...ol indicates the presence of a hazard if the instruction is ignored An image in the symbol illustrates the hazard type Prohibited Action This symbol indicates prohibited actions An image in the symbol illustrates a particular prohibited action Mandatory Action This symbol indicates mandatory actions An image in the symbol illustrates a mandatory action to avoid a particular hazard Example in this ...

Страница 8: ...dicates items that must be confirmed when handling hardware or operating software Tips Indicates information that is helpful to keep in mind when using this server Optical disk drive This server is equipped with one of the following drives depending on the order at the time of purchase These drives are referred to as optical disk drive in this document DVD ROM drive DVD Super MULTI drive Hard disk...

Страница 9: ...led information Notations in this document Official names of Windows Windows Server 2012 R2 Windows Server 2012 R2 Standard Windows Server 2012 R2 Datacenter Windows Server 2012 Windows Server 2012 Standard Windows Server 2012 Datacenter Windows Server 2008 R2 Windows Server 2008 R2 Standard Windows Server 2008 R2 Enterprise Windows Server 2008 Windows Server 2008 Standard Windows Server 2008 Ente...

Страница 10: ...n of the United States and other countries Adaptec its logo and SCSI Select are registered trademarks or trademarks of Adaptec Inc of the United States Avago LSI and the LSI Design logo are trademarks or registered trademarks of Avago Technologies in the United States and or other countries Adobe the Adobe logo and Acrobat are trademarks of Adobe Systems Incorporated DLT and DLTtape are trademarks...

Страница 11: ...products derived from this software without specific prior written permission THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS AS IS AND ANY EXPRESS OR IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED IN NO EVENT SHALL THE COPYRIGHT OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT INDIRECT...

Страница 12: ...ANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED IN NO EVENT SHALL THE OpenSSL PROJECT OR ITS CONTRIBUTORS BE LIABLE FOR ANY DIRECT INDIRECT INCIDENTAL SPECIAL EXEMPLARY OR CONSEQUENTIAL DAMAGES INCLUDING BUT NOT LIMITED TO PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES LOSS OF USE DATA OR PROFITS OR BUSINESS INTERRUPTION HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY WHETHER IN CONTRACT...

Страница 13: ...LAIMED IN NO EVENT SHALL THE COPYRIGHT OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT INDIRECT INCIDENTAL SPECIAL EXEMPLARY OR CONSEQUENTIAL DAMAGES INCLUDING BUT NOTLIMITED TO PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES LOSS OF USE DATA OR PROFITS OR BUSINESS INTERRUPTION HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY WHETHER IN CONTRACT STRICT LIABILITY OR TORT INCLUDING NEGLIGENCE OR OTHERWISE A...

Страница 14: ...n this document contact your sales representative 5 Regardless of article 4 NEC Corporation assumes no responsibility for effects resulting from your operations 6 The sample values used in this document are not actual values Keep this document for future use Latest editions This document was created based on the information available at the time of its creation The screen images messages and proce...

Страница 15: ...ct information about the location where a failure occurred and its cause if the server malfunctions See this section in case of a failure 5 Troubleshooting Describes how to identify the causes of problems and what actions are to be taken to address them See this section if you suspect a failure 6 Windows System Recovery Describes Windows recovery setup See this section if Windows is corrupt 7 Rese...

Страница 16: ...e power plug before installing or removing the server CAUTION Be sure to observe the following precautions to use the server safely Failure to observe the precautions may cause burns injury and property damage For details see Safety Precautions and Regulatory Notices Make sure to complete installation Do not get your fingers caught Be careful of handling internal components that may be at high tem...

Страница 17: ...wer outlet 4 Disconnect all the cables from the server 5 Pack the server securely to protect from damage shock and vibration Important If this server and internal optional devices are suddenly moved from a cold place to a warm place condensation will occur Wait for a sufficient period of time before using the server and other components Note Check and adjust the system clock before operating after...

Страница 18: ...es on our website We recommend you to apply the latest update always NEC corporate site http www nec com Support Downloads NEC also provides ExpressUpdate that helps you to download and install the updates that must be applied to BIOS and FW of the server ExpressUpdate is contained in EXPRESSBUILDER provided with the server Tips NEC recommends that you back up data before applying the latest updat...

Страница 19: ...mend that you periodically back up the data on HDD If a RAID array has been configured on your system back up the RAID configuration data We also recommend that you back up it after a rebuilding process required due to HDD failure See Chapter 2 6 Details of EXPRESSBUILDER for details 2 5 Cleaning Regularly clean the server to keep it in good condition WARNING Be sure to observe the following preca...

Страница 20: ...er and squeeze it firmly 5 Rub off stains on the server with the cloth prepared in step 4 6 Soak a soft cloth in water squeeze it firmly and wipe the server with it once again 7 Wipe the server with a dry cloth 2 5 2 Cleaning the tape drive A dirty tape drive head causes unsuccessful file backup and damages the tape cartridge Periodically clean the tape drive with the designated cleaning tape For ...

Страница 21: ... occurred follow the steps below 1 Check if the power cord and cables to other products are properly connected 2 See Chapter 1 5 Troubleshooting If you find a symptom similar to your problem take the action as instructed 3 Confirm that the required software has been properly installed 4 Scan for viruses using a commercial Antivirus Software If the problem persists after taking the measures above c...

Страница 22: ...ve Important Do not reset during dumping memory or restarting the server even if the message of virtual memory shortage appears 4 1 Collecting Event Logs To collect the various event logs of the server follow the steps below Tips If a STOP error system error or system stall occurs restart the system and follow the steps below 4 1 1 Windows Server 2012 R2 Windows Server 2012 1 Click Settings on Cha...

Страница 23: ...4 Collecting Failure Information Express5800 R120f 2E T120f Maintenance Guide 23 Chapter 1 Maintenance 2 Click Control Panel from Settings 3 Click System and Security of Control Panel ...

Страница 24: ...Application records events related to running applications Security records events related to security System records events that occur in Windows system components 5 Click Save All Events As from Action menu 6 Type the file name of the log file in File name 7 Select the type of the log file you want to save in Save as type and then click Save ...

Страница 25: ...er from Control Panel 2 Select the type of log in Windows Logs Application records events related to running applications Security records events related to security System records events that occur in Windows system components 3 Click Save All Event As from Action menu 4 Type the file name of the log file in File name 5 Select the type of the log file you want to save in Save as type and then cli...

Страница 26: ...tem error or stall occurs restart the system and then follow the procedure below 4 2 1 Windows Server 2012 R2 Windows Server 2012 1 Click Search on Charms Bar You can also use Run feature by right clicking on the lower left corner of the screen Search Run 2 Type msinfo32 exe in the text box and then press Enter key Search Run 3 System Information starts 4 Click Export from File menu 5 Type a file ...

Страница 27: ... For details see Chapter 1 7 2 How to Create a User Mode Process Dump File in Installation Guide Windows 4 4 Collecting Memory Dump If an error occurs the dump file will be saved to acquire necessary information You can specify any path for saving the diagnostic information For details see Chapter 1 7 1 Specifying Memory Dump Settings Debug Information in Installation Guide Windows Consult with yo...

Страница 28: ...s for the server Use the power cord that comes with the server Additionally check the power cord for broken shield or bent plugs Make sure the power breaker for the connected power outlet is on If the power cord is plugged to a UPS make sure the UPS is powered and it outputs power Refer to the manual that comes with the UPS for details Power supply to the server may be linked with UPS using the BI...

Страница 29: ...ck if the value specified for Power Threshold Pa is appropriate for normal startup To operate the server with Shutdown System being enabled the value of Power Threshold Pa must be fully considered 5 2 Problem of Starting EXPRESSBUILDER Unable to start EXPRESSBUILDER DVD Did you start the server and insert EXPRESSBUILDER DVD during POST Insert the DVD to the server and restart the server to retry A...

Страница 30: ...file Failed to get the parameters of a file Failed to write a file Failed to copy a file An undefined error occurred Contact your sales representative The following message appears after the Update command of EXPRESSBUILDER is run You need to format the disk in drive I before you can use it Do you want to format it I is subject to change depending on your hardware environment Click Cancel to close...

Страница 31: ...e partition created for installing the OS create a new partition again and then restart the installation Unable to install OS Is the hard disk drive properly installed Make sure that the hard disk drive is installed securely and that cables are properly connected Is the disk format correct Follow the table below to create a partition depending on the boot mode Boot mode Disk format UEFI Mode GPT G...

Страница 32: ... you check the precautions for installation For installing OS see Installation Guide Windows A product key is not requested Did you use the backup DVD ROM You do not need to type the product key when installing Windows with the backup DVD ROM The following devices are indicated as faulty devices in a Windows Server 2012 R2 Windows Server 2012 Server Core installation environment SM Bus Controller ...

Страница 33: ...AN cable properly connected If the LAN cable is not connected Windows is installed in workgroup setting not in domain setting After the OS is started join the domain by using Control Panel The following features are installed when installing IIS in Windows Server 2008 R2 Windows Server 2008 using EXPRESSBUILDER Windows Process Activation Service Process Model Configuration APIs Remote Server Admin...

Страница 34: ...ation of Windows Server 2012 R2 An application error is recorded in event log after restarting Ignore this event log because it does not affect system operation Unable to start from OS Installation Disc of Windows Server 2008 R2 or Windows Server 2008 Is X2APIC feature of the processor disabled Disable X2APIC feature of the processor by using BIOS Setup Utility Advanced Processor Configuration X2A...

Страница 35: ...oller properly Is the RAID controller mounted on the PCI slot for which the mounting is restricted Check the mounting restrictions of the server and then mount the RAID controller on the correct slot Are the hard disk drives properly installed Install the hard disk drives properly Is the SAS cable connected to the hard disk drive correctly Connect the SAS cable properly Is the EXPRESSBUILDER DVD i...

Страница 36: ...use Windows Server 2008 R2 or Windows Server 2008 with the unauthenticated license Choose Get genuine now and proceed license authentication The above message is an example of request for license authentication The message displayed on screen is subject to change depending on the license 5 5 Problem of Windows STOP Error Cannot turn the power OFF at the blue screen STOP error screen Perform the fo...

Страница 37: ...matically rebuild the RAID array Did you wait for sufficient time until the hard disk drive was replaced Follow the steps below to use the auto rebuilding feature 1 Remove a failure HDD 2 Wait for at least 90 seconds 3 Install a new HDD Is configuration correct Run LSI Software RAID Configuration Utility and confirm settings for Auto Rebuild TOP menu Objects Adapter Auto Rebuild The hard disk driv...

Страница 38: ...hen battery is being refreshed Check cache mode current value about 12 hours later Reconstruction Displayed when battery is being reconstructed Check cache mode current value after reconstruction completes If the battery is not found in spite of actions taken the battery may be faulty Consult with your sales representative Additional battery is not found or the following message appears in POST Th...

Страница 39: ...ually See Universal RAID Utility User s Guide in EXPRESSBUILDER for more information DISK LED flashes Does DISK LED flash frequently even while the hard disk drive is not accessed Ignore the flashing When Patrol Read is running the DISK LED flashes even if the hard disk drive is not being accessed If a SATA hard disk drive is used the DISK LED stays on When N8190 157A 158A 159 160 is used the name...

Страница 40: ... comes with the device to install its driver Is option board setting correct Refer to the manual that comes with the board for details to specify I O port address and other settings correctly The keyboard or mouse does not work Is the cable properly connected Make sure that the cable is connected to the connector on the front or rear of the server Is BIOS configuration correct Check the BIOS setti...

Страница 41: ...ual time In this case use NTP server or disable Windows Time Service Unable to connect to a network Is the cable connected properly Securely connect the proper cable to the network port on the rear of the server Additionally make sure that the cable conforms to the network interface standards Are BIOS settings correct Check the BIOS settings with BIOS Setup Utility Have you completed protocol and ...

Страница 42: ... Explorer and double click the icon of the set DVD drive Some menu items are grayed out Is your system environment correct Some software requires administrator privilege or needs to be operated on the server Run on the appropriate environment Unable to create the repository Are there free four drive letters Free at least four drive letters except A and B when creating the repository If the drive l...

Страница 43: ...rm the settings of Regional and Language Options Set the language settings of each tab to English US The problem of NEC ESMPRO ServerAgentService for Windows For details of NEC ESMPRO ServerAgentService for Windows see NEC ESMPRO ServerAgentService Installation Guide Windows in EXPRESSBUILDER The problem of NEC ESMPRO Manager For details of NEC ESMPRO Manager see NEC ESMPRO Manager Installation Gu...

Страница 44: ...isk using the eject button Eject the disk in the following steps 1 Press the power switch to turn off the server POWER SLEEP LED is off 2 Use a 100 mm long metal pin that is 1 2 mm in diameter or uncoil a thick paper clip and insert it into Eject Hole at the front of the tray Keep pressing slowly until the tray comes out Important Do not use toothpicks plastic and other fragile pins If you still c...

Страница 45: ...stall the OEM drivers copy the files under the following folder in EXPRESSBUILDER to removable media For the onboard RAID controller LSI Embedded MegaRAID Windows Server 2012 R2 010 win winnt oemfd ws2012r2 megasr1 Windows Server 2012 010 win winnt oemfd ws2012 megasr1 6 2 Recovery of Windows Server 2008 R2 and Windows Server 2008 If Windows does not start normally you can recover it by using the ...

Страница 46: ... that no processing is in progress when resetting the server 7 2 BMC Reset Press BMC RESET Switch only if a problem occurs in EXPRESSSCOPE Engine 3 BMC Do not press this switch usually To reset the BMC press BMC RESET Switch at least five seconds The remote management feature is disabled for about three minutes after the BMC is reset While the BMC is being initialized STATUS LED 1 and 2 light gree...

Страница 47: ...7 Resetting and Clearing the Server Express5800 R120f 2E T120f Maintenance Guide 47 Chapter 1 Maintenance R120f 2E T120f BMC RESET Switch BMC RESET Switch ...

Страница 48: ...hold POWER Switch of the server for at least four seconds The power is forcibly turned off To turn on the power back again wait at least 30 seconds after turning off the power Note If the remote power on feature is used cycle the power once to load the OS after the power has been forcibly turned off and then turn off the power again by shutting down the OS R120f 2E T120f POWER Switch Keep pressing...

Страница 49: ...h You can also clear the password of BIOS Setup Utility SETUP by using the jumper switch Tips Use BIOS Setup Utility SETUP usually to return the settings to the factory settings To clear the password or the CMOS memory use the corresponding jumper switch illustrated in the figure below Important Do not change any other jumper switch Any change will cause the server to fail or malfunction Clear CMO...

Страница 50: ...and Regulatory Notices Make sure to complete installation Do not get your fingers caught Avoid installing under extreme temperature conditions Important Take anti static measures before operating the server For details see Safety Precautions and Regulatory Notices Clearing CMOS memory 1 Turn off the server and disconnect the AC power cord from outlet See Getting Started or Chapter 2 1 Installing I...

Страница 51: ...nal Devices in User s Guide to remove Top Cover or Side Cover 2 Confirm the position of Clear Password Jumper 3 Change the jumper switch from Protect to Clear 4 Reassemble the server and press POWER Switch to turn on the server 5 POST halts with the following error message ERROR 8007 Password Cleared By Jumper Press F1 to resume F2 to Setup 6 Turn off the server and return the jumper switch to Pro...

Страница 52: ...gnostics After turning off the server or restarting the server run System Diagnostics as follows 1 Run EXPRESSBUILDER and choose Tool menu from Boot Selection Menu See Chapter 2 6 Details of EXPRESSBUILDER for details Note Choose English if Language Selection Menu appears Press Y key if Hit key to continue y Y appears in Redirection Mode 2 From Tool menu choose Test and diagnostics 3 From Test and...

Страница 53: ...te window Test summary window Shows the results of each test Move the cursor and press Enter key on the cursor line to display the details of the test If an error is detected by System Diagnostics the relevant test result in the Test summary window is highlighted in red and Abnormal End is displayed in the result on the right side Move the cursor to the test that detected the error and press Enter...

Страница 54: ...stics completion screen of the above diagnostics Device List Shows a list of connected devices Log Info Shows the log information of the diagnostics To save it connect FAT formatted removable media and then choose Save F Option Optional features can be used from this menu Reboot Reboots the server 5 Choose Reboot in Enduser Menu The server restarts Remove EXPRESSBUILDER DVD from the drive System D...

Страница 55: ... on a display and other peripheral devices and then turn on the server 2 Press F4 key while the message below is displayed Press F2 SETUP F3 Internal flash memory F4 ROM Utility F12 Network 3 Keyboard Selection Menu appears after POST completion The following menu appears after choosing a keyboard type 4 Choose a feature from the menu See Chapter 1 9 2 Features of Offline Tools for more informatio...

Страница 56: ...t requires Off line Maintenance Utility occurs After starting up Off line Maintenance Utility the following features are available to run IPMI Information Viewer Displays System Event Log SEL Sensor Data Record SDR and Field Replaceable Unit FRU in Intelligent Platform Management Interface IPMI and also back up such logs Using this feature system errors and events can be investigated to locate the...

Страница 57: ...agement LAN port If Shared BMC LAN feature is used connect the LAN cable to the corresponding LAN connector To use the remote KVM Remote Management Extension License N8115 04 is mandatory You can also control Off line Tools remotely by using BIOS Console Redirection Tips In console redirection connection if the corrupted text is displayed on terminal screen change font type character code appropri...

Страница 58: ...ation Describes the RAID configuration utility installed in the server 6 Details of EXPRESSBUILDER Describes the EXPRESSBUILDER attached to the server 7 EXPRESSSCOPE Engine 3 Describes EXPRESSSCOPE Engine 3 8 NEC ESMPRO Describes NEC ESMPRO used to manage and monitor the server 9 NEC Product Info Collection Utility Describes the NEC Product Info Collection Utility 10 Universal RAID Utility Describ...

Страница 59: ...UP F3 Internal Flash Memory F4 ROM Utility F12 Network a different message may appear depending on the environment If you press F2 SETUP will start after POST and the Main menu appears You can also start SETUP by pressing F2 key while expanding option ROM 1 2 Parameter Descriptions The SETUP utility has the following six major menus Main menu Advanced menu Security menu Server menu Boot menu Save ...

Страница 60: ...ct a display language for SETUP If you run SETUP with BIOS Redirection Port enabled other than Disabled English is automatically selected At that time you cannot change setting of System Language If BIOS Redirection Port is set to Disabled the language set in this option is used at the next startup of SETUP and you can change the language setting System Date WWW MM DD YYYY Set the system date Syst...

Страница 61: ...he menus that show a to their left select a menu and press the Enter key to display its submenu When UEFI is selected for Boot Mode When Legacy is selected for Boot Mode Note The Network Stack Configuration submenu and UEFI Driver Configuration submenu cannot be selected if Legacy is specified for Boot Mode They can be selected only when UEFI is selected for Boot Mode ...

Страница 62: ... Adjacent Cache Line Prefech Disabled Enabled Set the optimal access from memory to cache to either Enabled or Disabled Execute Disable Bit Disabled Enabled Enable or disable Execute Disable Bit feature This option is displayed only when the installed processor supports this feature VT x Disabled Enabled Enable or disable Intel R Virtualization Technology feature to virtualize processor Active Pro...

Страница 63: ...T x and VT d The X2APIC feature must be enabled when using an OS shown below Windows Server 2012 Windows Server 2012 R2 The X2APIC feature must be disabled when using an OS shown below Windows Server 2008 Windows Server 2008 R2 See Chapter 1 Installing Windows in Installation Guide and determine whether this feature is enabled or disabled according to description in Before Starting Setup appropria...

Страница 64: ... when the processor 1 supports Intel 64 architecture Hyper Threading Display only Supported is shown when the processor 1 supports Hyper Threading Technology Processor 2 CPUID Display only Shows the ID or Processor 2 Not Installed indicates that no processor is installed in processor socket 2 Processor Type Display only Shows the type of Processor 2 Processor Speed Display only Shows the clock spe...

Страница 65: ...e or disable the Enhanced Intel SpeedStep R Technology feature This option is displayed only when the installed processor supports this feature Energy Performance Performance Balanced Performance Balanced Energy Energy Efficient Specify whether the performance is preferred or energy saving is preferred while processor is running This option is displayed only when EIST is set to Enabled Turbo Boost...

Страница 66: ...e should take precedence over the I O workload Uncore Frequency Scaling Disabled Enabled Enable or disable the feature that adjusts the Uncore operating frequency dynamically Uncore Frequency Coordination Disabled Enabled Enable or disable the feature that adjusts the operating frequency of Uncore in each processor This option is displayed when Uncore Frequency Scaling is set to Enabled Factory se...

Страница 67: ...s degraded Memory Retest No Yes When this option is set to Yes error information on memory is cleared and all DIMMs are reconfigured at the next startup No is automatically selected after DIMMs are reconfigured Memory Frequency Limit Auto 1333 MHz 1600 MHz 1866 MHz 2133 MHz Specify the upper limit of operating frequency of memory The operating frequency may be lowered than the specified value depe...

Страница 68: ...This option is available when Disabled is selected for Cluster On Die Memory RAS Mode Independent Mirroring Lock Step Sparing Specify the memory RAS mode See Chapter 2 Memory RAS Feature in User s Guide Patrol Scrub Disabled Enabled Enable or disable a memory RAS feature Patrol Scrubbing Demand Scrub Disabled Enabled Enable or disable a memory RAS feature Demand Scrubbing Factory setting ...

Страница 69: ...he sparing feature is available in the current memory configuration and Sparing is specified for Memory RAS Mode Lock Step Display only Supported is shown when the Lock Step feature is available in the current memory configuration and Lock Step is specified for Memory RAS Mode CPU1_DIMM1 8 Status CPU2_DIMM1 8 Status Display only Shows the capacity and status of each DIMM Number Indicates the memor...

Страница 70: ...State Power Management When Auto is selected an appropriate level is automatically specified AER Support Disabled Enabled Enable or disable the feature that allows the OS to control PCIe Advanced Error Reporting Onboard LAN VGA is excluded 4GB PCI Hole Granularity 3 GB 2 GB 1 GB Specify the size of the address space for the PCI device PCI Bus Static Allocation Disabled Enabled Enable or disable st...

Страница 71: ...ied for Boot Mode LAN Controller Disabled Enabled Enable or disable the onboard LAN controller This option is fixed to Enabled if Shared LAN is set to Enabled for off line tools LANX Option ROM Scan Disabled Enabled Enable or disable the option ROM SCAN for onboard LAN This option is displayed according to the number of LAN ports Disabled is selected for any other LAN ports than LAN1 PCIXX Slot Op...

Страница 72: ...t Auto 2 5 GT s 5 0 GT s Specify the upper limit of the link speed of onboard PCI devices PCIXX Slot Link Speed Limit 2 5 GT s 5 0 GT s 8 0 GT s Specify the upper limit of the link speed of the PCI device in each PCI slot XX 1 2 3 4 PCI5 Slot Link Speed Limit 2 5 GT s 5 0 GT s Specify the upper limit of the link speed of the PCI slot 5 The speed must not exceed the one specified in Target Link Spe...

Страница 73: ...cessor configuration QPI Frequency Limit Auto 6 4 GT s 8 0 GT s 9 6 GT s Specify the upper limit of the QPI link speed VT d Disabled Enabled Enable or disable Intel R Virtualization Technology for Directed I O feature Virtualization of I O feature This option is displayed only when the installed processor supports this feature I OAT Disabled Enabled Enable or disable Intel I O Acceleration Technol...

Страница 74: ...s on the left move the cursor to it and then press the Enter key to show its submenus For details about the options see the table below Option Parameter Description SATA Information SATA Mode Disabled IDE Mode AHCI Mode Set SATA mode Hard Disk Pre Delay Disabled 3 Seconds 6 Seconds 9 Seconds 12 Seconds 15 Seconds 21 Seconds 30 Seconds Specify the delay time before HDD is accessed during POST Facto...

Страница 75: ...SATA Information submenu For details about the options see the table below Option Parameter Description SATA Port0 Display only Shows a device connected to each port Not Present is shown when no device is connected to the SATA port SATA Port1 SATA Port2 SATA Port3 SATA Port4 Factory setting ...

Страница 76: ...en the Start Unit command is issued to a USB device Controller Timeout 1 sec 5 sec 10 sec 20 sec Specify the timeout period when the Control Bulk or Interrupt Transfer command is issued to the USB Controller XHCI Mode Smart Auto Auto Enabled Disabled Specify the operation mode of the USB 3 0 controller Smart Auto Takes over the USB 3 0 settings at POST according to the supported OS Auto Enables US...

Страница 77: ... Serial Port Configuration submenu From the Advanced menu select Serial Port Configuration and then press the Enter key to display the menu screen shown below From BIOS Redirection Port select Serial Port A or Serial Port B and then press the Enter key to display the menu screen shown below ...

Страница 78: ...e that supports this feature must be connected If the connected device does not support this feature the serial ports will fail to return from halt state Console Redirection Settings BIOS Redirection Port Disabled Serial Port A Serial Port B Enable or disable console redirection for a specified serial port Specifying Serial Port A or Serial Port B allows direct connection via a terminal unit such ...

Страница 79: ...screen shown below For details about the options see the table below Option Parameter Description Network Stack Disabled Enabled Enable or disable UEFI Network Stack If this option is set to Enabled the menu items below appear PXE Configuration Network Mode Disabled IPv4 IPv6 Specify the PXE network mode Media Detect Count 1 50 Specify the number of times trying to detect media at PXE connection i...

Страница 80: ...eter Description iSCSI Initiator Name Alphanumeric character between 4 and 223 Specify the name of the iSCSI Initiator The initiator name must be IQN format iSCSI Qualifier Name The menu items below can be selected when iSCSI Initiator Name is specified Add an Attempt Attempt XX Delete Attempts Change Attempt Order Factory setting ...

Страница 81: ...20f Maintenance Guide 81 Chapter 2 Useful Features 1 Add an Attempt submenu Note A MAC address is displayed when the onboard LAN controller or the UEFI driver for the PCI device is loaded Option Parameter Description MAC XX XX XX XX XX XX ...

Страница 82: ...on Establishing Timeout 100 16000 20000 Specify the timeout time in msec for iSCSI connection OUI format ISID Display only Displays the OUI format ISID Configure ISID 6 digit numerics Specify the lower 3 bytes of the OUI format ISID The MAC address is stored by default Enable DHCP Disabled Enabled Enable or disable the DHCP server Initiator IP Address IP Address Specify the IP address of the initi...

Страница 83: ...pecify the authentication type CHAP Type One way Mutual Specify the CHAP type This item is displayed when CHAP is selected for Authentication Type CHAP Name Up to 126 Alphanumeric characters Specify the CHAP name This item is displayed when CHAP is selected for Authentication Type CHAP Secret Alphanumeric characters between 12 and 16 digits Specify the CHAP secret This item is displayed when CHAP ...

Страница 84: ...u See MAC XX XX XX XX XX XX submenu 3 Delete Attempts submenu Option Parameter Description Attempt XX Disabled Enabled Select Enabled for an iSCSI attempt you want to delete Commit Changes and Exit Save the current setting and return to the iSCSI Configuration submenu Discard Changes and Exit Discard the current setting and return to the iSCSI Configuration submenu Factory setting ...

Страница 85: ...nge Attempt Order Specify the priority of iSCSI attempt Press the Enter key to open the pop up window and specify the priority by using or key Commit Changes and Exit Save the current setting and return to the iSCSI Configuration submenu Discard Changes and Exit Discard the current setting and return to the iSCSI Configuration submenu Factory setting ...

Страница 86: ...rd LAN controller or a UEFI driver for a PCI device is loaded The on screen menu depends on the specified UEFI driver Driver Health a Driver Health submenu Option Parameter Description UEFI Driver Name Display only Displays the status of the UEFI driver This item is displayed when the onboard LAN controller or a UEFI driver for a PCI device is loaded and the UEFI driver supports the Driver Health ...

Страница 87: ...he Enter key to show its submenus Then configure the settings Select Administrator Password or User Password and then press the Enter key to display the screen where you can register change the password Tips Administrator Password must be set before setting User Password Do not set any password before installing OS If you have forgotten any password contact the store where you purchased the produc...

Страница 88: ...to set user right is displayed With this password access to SETUP menus is limited The user password can be set when SETUP is started by administrative right or user right Security Configuration Password On Boot Disabled Enabled Enable or disable the feature that requires a password entry on boot This option can be selected when Administrator Password is set Disable USB Ports None Front Rear Inter...

Страница 89: ...tenance Guide 89 Chapter 2 Useful Features 1 Trusted Computing submenu From the Security menu select Trusted Computing and then press the Enter key to display the menu screen shown below If you enable TPM Support the following menu screen appears ...

Страница 90: ...ership TPM Clear Configure TPM operation This option can be selected when TPM State is set to Enabled Current TPM Status Information TPM Enabled Status Display only Shows the current status of TPM TPM Active Status Display only TPM Owner Status Display only Intel R TXT Configuration TXT Support Disabled Enabled Enable or disable Trusted Execution Technology features This option can be selected whe...

Страница 91: ...ted when a PCIe Uncorrectable error is detected and PCI PERR or SERR is detected FRB 2 Policy Retry 3 Times Disable FRB2 Timer Always Reset Specify how the system should operate if an FRB level 2 error occurs Boot Monitoring Disabled 5 60 minutes Enable or disable the boot monitoring feature and specify the timeout period To use this feature NEC ESMPRO ServerAgentService must be installed If start...

Страница 92: ...on is set to Disabled OS booting continues regardless of user s response even if an error is detected during POST Memory Error Halt Boot Enable or disable the feature to suppress OS booting when POST detects a memory degradation error until user s response is made This option is valid only when POST Error Pause is set to Enabled Even if this option is set to Boot the system halts at the end of POS...

Страница 93: ...ime The power is measured only at the next POST execution This parameter is automatically changed to Disabled after the measurement Always The power is measured at every POST execution One Time is selected when Load Setup Defaults is executed If you intend to measure the power by this setting do not use the power control feature that limits power consumption See Chapter 2 4 Power Control Feature f...

Страница 94: ...splay only Shows the serial number of the system Chassis Part Number Display only Shows the part number of the chassis Chassis Serial Number Display only Shows the serial number of the chassis Onboard LAN1 MAC Display only Shows the MAC address of onboard LAN1 Onboard LAN2 MAC Display only Shows the MAC address of onboard LAN2 Management LAN MAC Display only Shows the MAC address of the management...

Страница 95: ...tion is selectable when AC LINK is set to Power On or Last State Delay Time 45 600 Specify the delay time in unit of seconds The minimum configurable time may be changed from the factory set value The minimum configurable time is displayed when executing Load Setup Defaults This menu appears when Power ON Delay Time Mode is set to Manually Setting Standby Power Save Disabled Enabled Enable or disa...

Страница 96: ...onment to reduce power consumption Factory setting The table below shows the operation of DC power when the AC power is turned off once and then back on in accordance with the AC LINK setting System status before AC power was turned off AC LINK setting Stay Off Last State Power On Operating DC power is ON Off On On Halting DC power is also OFF Off Off On Forced shutdown Off On On Continue pressing...

Страница 97: ...re of the keyboard Setup Prompt Timeout 0 65535 Specify the time until F2 is pressed to launch SETUP Boot Mode Legacy UEFI Specify the boot mode Select UEFI for the following OS Windows Server 2012 or Windows Server 2012 R2 Select Legacy for the following OS Windows Server 2008 or Windows Server 2008 R2 See Chapter 1 Installing Windows in Installation Guide and determine the Boot Mode according to...

Страница 98: ...b The priority of bootable devices in Priorities of that device is determined as follows Devices other than USB device e g SATA device RAID is given higher priority and USB device is given priority next to non USB devices c Bootable device If a bootable device has been set to Disabled cancel the Disabled status and register the device in Priorities of that device type 4 If a Remote Management Exte...

Страница 99: ...ges and Power Off The SETUP utility closes with all the changes saved in NVRAM After the SETUP utility closes the power of the server is automatically turned off d Discard Changes and Power Off The SETUP utility closes without saving the changes in NVRAM The setting at startup of SETUP utility is retained After the SETUP utility closes the power of the server is automatically turned off e Load Set...

Страница 100: ...guration 1 If you press the F4 key while the POST is running the Keyboard type selection menu appears Keyboard type selection menu 2 When you select a type of keyboard that is connected to the server the Off line TOOL MENU appears Off line TOOL menu 3 Selecting Server Configuration Utility in Off line TOOL MENU starts Server Configuration Utility ...

Страница 101: ...ge parameter value for each item select OK to apply the new value to BMC See Chapter 2 2 2 EXPRESSSCOPE Engine 3 for details b ECO You can view or set information concerning ME Management Engine See Chapter 2 2 3 6 ECO for details c Help You can open help screen of Server Configuration Utility d Return to the previous menu You can exit Server Configuration Utility and return to Off line TOOL MENU ...

Страница 102: ...o BMC See Chapter 2 2 3 Configuration Menu for details b Clear SEL You can erase SEL System Event Log of BMC See Chapter 2 2 4 Clear SEL for details c Reset You can reset BMC without changing configuration information See Chapter 2 2 5 Reset for details d Configuration Initialization You can initialize BMC configuration information to restore the default settings See Chapter 2 2 6 Initializing Con...

Страница 103: ...r Management You can manage users who use BMC See Chapter 2 2 3 2 User Management for details c Mail Alert You can view E mail alert issued from BMC and change parameter setting See Chapter 2 2 3 3 Mail Alert for details d SNMP Alert You can view SNMP alert issued from BMC and change parameter setting See Chapter 2 2 3 4 SNMP Alert for details e System Operation You can set parameters for remote K...

Страница 104: ...uplex at speed of 100 Mbps 10Mbps Full Connecting by Full Duplex at speed of 10 Mbps 10Mbps Half Connecting by Half Duplex at speed of 10 Mbps Auto Negotiation BMC MAC Address Display MAC Address of BMC DHCP Determine whether to dynamically obtain an IP address from a DHCP server If this item is set to Enable BMC set the value obtained from DHCP server on IP Address Subnet Mask and Default Gateway...

Страница 105: ...e Enable SSH Port Number Specify the SSH port number 11 22 1 Can be specified if the server supports this feature 2 When set to Shared BMC LAN the BMC LAN port is disabled When set to Shared BMC LAN the system OS LAN port also transmits or receives data Thus the network performance may be reduced due to load of system LAN or BMC LAN 3 If an illegal value is specified for subnet mask an error messa...

Страница 106: ...n Disable User Domain Name Specify the user domain name 5 6 Blank Timeout Specify timeout period for connection with Domain Controller 5 120 Domain Controller Server1 Enable or disable Domain Controller Server 1 5 7 Enable Server Address1 Specify IP address of Domain Controller Server 1 5 8 Blank Domain Controller Server2 Enable or disable Domain Controller Server 2 5 7 Disable Server Address2 Spe...

Страница 107: ...to 19 ASCII characters can be used excluding blank quotation ampersand question mark equal sign and 4 Privileges are defined as follows Administrator User who has administrator right All operations are allowed Operator User who can operate the machine Session management license registration remote KVM media configuration and update are not allowed User General user Viewing IPMI information only is...

Страница 108: ... 2 1 Disable To 2 E Mail Address Specify the mail address of To 2 2 3 Blank To 3 Select Enable Disable of To 3 1 Disable To 3 E Mail Address Specify the mail address of To 3 2 3 Blank From Specify the mail address of From 3 Blank Reply To Specify the mail address of Reply To 3 Blank Subject Specify the Subject 4 Blank SMTP Server SMTP Server Specify the SMTP Server 5 0 0 0 0 SMTP Port Number Speci...

Страница 109: ...ert Test Execute test by sending an alert by mail 10 1 When Mail Alert is enabled at least one address should be enabled 2 Can be specified only when To X is set to Enable 3 Up to 255 characters including alphanumeric hyphen underscore period and at mark can be used 4 Up to 63 alphanumeric characters excluding and can be used 5 Up to 255 alphanumeric characters hyphen and period can be used for fu...

Страница 110: ...able or disable tertiary receiver 4 Disable IP Address3 Specify the IP Address of tertiary receiver 5 0 0 0 0 Alert Level Alert Level Specify the kind of event to alert Error Warning Error When Error is detected in each sensor type the alert is sent to the valid receiver Error Warning When Error or Warning is detected in each sensor type the alert is sent to the valid receiver Error Warning Inform...

Страница 111: ...uage Select a keyboard language Japanese JP English US French FR German DE English US Remote Media Encryption Enable or disable encryption Enable Remote CD DVD No Encryption Specify the port number of remote CD DVD port when encryption is disabled 1 5120 Remote USB Memory No Encryption Display the port number of remote USB memory when encryption is disabled Remote CD DVD port number 2 Remote FD No...

Страница 112: ...erage power consumption Watt CPU Throttling Shows Current Maximum Minimum Average CPU throttling rate 2 Memory Throttling Shows Current Maximum Minimum Average memory throttling rate 2 Configuration Aggressive Mode Enable or disable Aggressive Mode Disable Power Threshold Pa Specify power threshold in Aggressive Mode Allowable range is between AAA and Maximum Power Consumption Watt 3 4 Maximum pow...

Страница 113: ...ion Power Optimized Optimize power consumption Performance Optimized Disable CPU Cores Specify the number of cores to be disabled Allowable value is between 0 and Number of maximum cores 1 7 0 1 These values are reference purpose only Each value might be different from the actual value which depends on your system configuration 2 Technology that decreases frequency or duty cycle of clock and suppr...

Страница 114: ...ey Specify the Authentication Key 4 5 guest Redirection Enable or disable Redirection feature 4 6 Enable 1 When this item is changed to from Overwrite oldest SEL all log records in the SEL Repository are cleared 2 Disabling Platform Event Filter also disables SNMP alert 3 When BMC can be managed directly from NEC ESMPRO Manager Ver 5 4 or later this item must be set to Enable If it is set to Enabl...

Страница 115: ...essing and returns to BMC Configuration menu Enter key Clears SEL 2 5 Reset If you select Reset on EXPRESSSCOPE Engine 3 menu the confirmation message as show below appears Confirmation message Reset ESC key Aborts processing and returns to BMC Configuration menu Enter key Resets BMC It takes about several minute to restart BMC Note Do not shutdown the system reboot the system or perform any switc...

Страница 116: ...nfirmation message as show below appears Confirmation message Initialization ESC key Aborts processing and returns to Main menu Enter key Initializes BMC configuration settings and restores the default value After initialization it takes several minutes to restart BMC Note Do not shutdown the system reboot the system or perform any switch operation while BMC is being initialized for approximately ...

Страница 117: ... up data Flash FDD can be used for a temporary data only 3 1 1 Compensation for recorded data NEC does not pay compensation for data recorded on Flash FDD even if the data is lost 3 1 2 Handling Flash FDD Flash FDDs are consumables If Flash FDD causes an error exchange to a new Flash FDD Do not turn off the server while the access LED of Flash FDD is blinking Flash FDD cannot be connected to a USB...

Страница 118: ...DD Express5800 R120f 2E T120f Maintenance Guide 118 Chapter 2 Useful Features 3 1 3 Use in EXPRESSBUILDER Connect Flash FDD after Home Menu appears Remove Flash FDD from the server before closing EXPRESSBUILDER ...

Страница 119: ...ser s Guide or NEC ESMPRO Manager online help 4 1 Supported OS The power control feature is available for the following OSs Windows Server 2008 Standard Windows Server 2008 Enterprise Windows Server 2008 Standard x64 Windows Server 2008 Enterprise x64 Windows Server 2008 R2 Standard x64 Windows Server 2008 R2 Enterprise x64 Windows Server 2012 Standard x64 Windows Server 2012 Datacenter x64 Window...

Страница 120: ...ng Windows Server 2008 R2 2012 2012 R2 Ignore the following event when Windows Server 2008 R2 2012 or 2012 R2 is run on the server This event is logged at the normal operation of controlling the server power Source Kernel Processor Power Event ID 37 Level Warning User SYSTEM Source Kernel Processor Power Event ID 37 ...

Страница 121: ...nfiguration Utility starts Press Ctrl M or Enter to run LSI Software RAID Configuration Utility Tips If you fail to press Ctrl M keys or Enter key or the system proceeds without displaying the following screen restart the system and press Ctrl M keys on POST screen 1 x in LSI Software RAID Configuration Utility Verx xx represents the version of utility 2 mm dd yyy represents created date 3 z in BI...

Страница 122: ...eatures 5 1 1 Quitting LSI Software RAID Configuration Utility To quit the utility press the Esc key on the TOP menu of LSI Software RAID Configuration Utility Select Yes Press CTRL ALT DEL To Reboot The System When the above message appears press Ctrl Alt Del keys The server restarts Yes No Exit ...

Страница 123: ...dapter Select an adapter Rebuild Rate 30 Percentage of IO for Rebuild Chk Const Rate 30 Percentage of IO for Check Consistency FGI Rate 30 Percentage of IO for Foreground Initialize BGI Rate 30 Percentage of IO for Background Initialize Disk WC Off Use or not use Write Cache of Adapter unavailable on LSI Software RAID Read Ahead On On Off Read Ahead Bios State Enable Enable or disable LSI Software...

Страница 124: ... of Virtual Drive Disk WC Display Write Cache Policy of Virtual Drive Read Ahead Display Read Ahead Policy of Virtual Drive Physical Drive Operation of physical drive Physical Drive Selection Menu Select a physical drive Make HotSpare Specify hot spare disk used for Auto Rebuild Force Online Forcibly make physical devices online Change Drv State Forcibly make a physical device offline if it is inc...

Страница 125: ...onfiguration clears the existing configuration To add configuration to the existing configuration select View add Configuration Note You cannot specify the Virtual Drive capacity on the Easy Configuration menu Use New Configuration or View Add Configuration instead For RAID10 the Virtual Drive is configured with the maximum capacity You cannot specify the capacity For RAID0 you can skip the step f...

Страница 126: ... New Configuration ARRAY SELECTION MENU screen appears 4 Move the cursor onto the physical device to be included in the disk array and then press the Space key The display for the selected physical device changes from READY to ONLINE ONLINE A00 00 ONLINE A00 01 PORT 0 1 New Configuration ARRAY SELECTION MENU READY READY PORT 0 1 New Configuration ARRAY SELECTION MENU ...

Страница 127: ... Press the F10 key to create a virtual drive The Virtual Drives Configure screen appears The figure below shows an example of RAID1 configured with two physical devices xxx xxxGB shows the capacity Units MB Size xxxxxxMB DWC Off RA On Accept SPAN NO RAID 1 Virtual Drive 0 Virtual Drive s Configured VD RAID Size Stripes StripeSz Status 0 1 xxx xxxGB 2 64 KB ONLINE SPAN 1 A 0 Select Configurable Arr...

Страница 128: ...the unit MB GB or TB used in the Size field 3 Size Specify the size of the virtual drive Up to eight virtual drives can be created per RAID Controller You cannot specify the size for RAID10 4 DWC Disk Write Cache Specify the method for writing cached data to the disk Parameter Remarks Off Write through On Write back Recommended For this server write back is recommended for good performance Note ho...

Страница 129: ...mation 12 Press the Esc key to return to the TOP menu screen and then select Initialize 13 On the Virtual Drives screen move the cursor to the virtual drive to be initialized and then press the Space key The virtual drive is selected 14 Press the F10 key 15 Select Yes to start initialization When the progress bar on the Init Of VD Is In Progress screen indicates 100 initialization is completed Pre...

Страница 130: ...ysical device indicating FAIL and then press the Space key to select it The color of FAIL indication for the selected physical device changes to pink 5 Press the F10 key 6 Select Yes to start the rebuild process When the Completed indication on the REBUILDING screen indicates 100 the rebuild process is completed 7 Press the Esc key to return to the TOP menu and exit LSI Software RAID Configuration...

Страница 131: ...d then Physical Drive The Objects PHYSICAL DRIVE SELECTION MENU screen appears 4 Move the cursor onto the physical device to be hot spared and then press the Enter key 5 Select Make HotSpare 6 When you select Yes the display for the physical device changes to HOTSP ONLINE A00 00 ONLINE A00 01 PORT 0 1 Objects PHYSICAL DRIVES SELECTION MENU READY 2 Connect the physical device Run LSI Software RAID ...

Страница 132: ...nu screen and then exit LSI Software RAID Configuration Utility Note To cancel the hot spare setting select Objects and then Physical Drive move the cursor onto the physical device to be canceled for hot sparing press the Enter key and then select Change Drv State ONLINE A00 00 ONLINE A00 01 PORT 0 1 Objects PHYSICAL DRIVES SELECTION MENU HOTSP 2 ...

Страница 133: ...reen appears 3 Move the cursor onto the virtual drive to be checked for consistency and press the Space key The virtual drive is selected 4 Press the F10 key 5 Select Yes to start consistency checking When the Completed indication on the CC Under Progress screen indicates 100 the consistency check is completed 6 Press the Esc key to return to the TOP menu and exit LSI Software RAID Configuration U...

Страница 134: ... virtual drive to be removed and then press the Delete key Select Yes when the message Want To Delete A VD is displayed 2 Force Online Use this feature to forcibly put a physical device in the FAIL status online From the TOP menu select Objects Physical Drive select the target physical device and then select Force Online 3 Rebuild Rate Use this feature to specify the rebuild rate From the TOP menu...

Страница 135: ...server and wait for POST to proceed After a while the following message appears at the bottom left of the screen Press F2 SETUP F4 ROM Utility Press CTRL P MEBX If you press the F2 key SETUP starts upon completion of POST and the Main menu is displayed You can also start SETUP by pressing the F2 key while expanding option ROM Tips If you fail to press the F2 key or the system proceeds without disp...

Страница 136: ...nced menu The Advanced menu appears if you move the cursor to the position of Advanced If you select UEFI Driver Configuration and press the Enter key the following submenu appears Select LSI Software RAID Configuration Utility and press the Enter key The TOP menu of LSI Software RAID Configuration Utility appears ...

Страница 137: ...de 137 Chapter 2 Useful Features 5 4 3 Quitting LSI Software RAID Configuration Utility To quit the utility press the Esc key on the TOP menu of LSI Software RAID Configuration Utility When the following screen appears the LSI Software RAID Configuration Utility is exited ...

Страница 138: ...ion UEFI driver version BIOS Version UEFI BIOS version Change Controller Properties Change of the parameter for the RAID controller Apply Changes Reflecting the change Set Factory Defaults Setting to the default value Set Boot Device Setting of the Virtual Drive to start up the OS Rebuild Rate 30 Ratio of the Rebuild IO 30 Background Initialization BGI Rate 30 Ratio of the Background Initialize IO...

Страница 139: ...tting is Enabled Read Ahead Enable Read Ahead setting View Associated Drives Displays the HDD configuring the Virtual Drive Select Virtual Drive Operations Virtual Drive operation Select Virtual Drive Virtual Drive selection Start Locate Device dependent Lights on blinks the LED of the slot on which the selected Virtual Drive is mounted Stop Locate Device dependent Lights off the LED of the slot o...

Страница 140: ...ns of the Physical Drives Select Drive Physical Drive selection Start Locate Device dependent Lights on blinks the LED of the slot on which the selected Physical Drive is mounted Stop Locate Device dependent Lights off the LED of the slot on which the selected Physical Drive is mounted Drive Operation Operations executed in the Physical Drive Operation Progress Progress of the operations being exe...

Страница 141: ...ect Virtual Drive Management and then Create Configuration 3 For Select RAID Level on the following screen select the RAID level RAID0 RAID1 or RAID10 Run LSI Software RAID Configuration Utility Create add Virtual Drive Check the Virtual Drive settings Initialize the Virtual Drive Perform Consistency Check Exit LSI Software RAID Configuration Utility Install the OS and Universal RAID Utility 1 1 T...

Страница 142: ...the existing Drive Group The procedures to create the virtual drive in each case are following below Note Up to eight virtual drives can be created For RAID10 only creating a new virtual drive is available For RAID10 the virtual drive is configured with the maximum capacity You cannot specify the capacity 4 1 New creation RAID0 RAID1 1 On the screen shown in step 3 select Unconfigured Capacity for...

Страница 143: ...physical device type is displayed on the following screen select the physical device to be created and select Enable 4 Select all of the physical devices to be created select Apply Changes and then select OK on the next screen Note You may select either of the upper or lower Apply Changes which is provided at two locations ...

Страница 144: ...rive Size Unit Specify the unit MB GB TB used for Virtual Drive Size 5 4 Disk WC Specify the Disk Write Cache policy Parameter Remarks Enable Write back Disable Write through Recommended For this server Setting Enable is recommended for good performance Note however that cached data may be lost at an unexpected power failure Selecting Disable degrades performance by approximately 50 comparing with...

Страница 145: ...145 Chapter 2 Useful Features 6 When all the settings are completed select Save Configuration Note You may select either of the upper or lower Save Configuration which is provided at two locations 7 Select Yes and then select OK on the next screen A virtual drive is created ...

Страница 146: ...ter 2 Useful Features 4 2 New creation RAID10 1 Select RAID10 for Select RAID Level 2 Select Select Drives under Span1 and then select the device type for Select Media Type Note The Both option is not available The options for Select Media Type vary depending on the connected device ...

Страница 147: ...e selected physical device is displayed select two physical devices to be created and then select Enabled 4 Select all of the physical devices to be created select Apply Changes and then select OK on the next screen Note You may select either of the upper or lower Apply Changes which is provided at two locations ...

Страница 148: ...2 and then select the device type for Select Media Type 7 When the selected physical device is displayed select two physical devices to be created and then select Enabled 8 Select all of the physical devices to be created select Apply Changes and then select OK on the next screen Note You may select either of the upper or lower Apply Changes which is provided at two locations ...

Страница 149: ...ecify the Read Ahead setting Parameter Remarks Disable Does not perform read ahead Enable Performs read ahead Recommended Note For RAID 10 the virtual drive can be created only with the maximum size Parameter Remarks Enable Wright back Disable Write through Recommended For this server Setting Enable is recommended for good performance Note however that cached data may be lost at an unexpected powe...

Страница 150: ... Chapter 2 Useful Features 10 When all of the settings are complete select Save Configuration Note You may select either of the upper or lower Save Configuration which is provided at two locations 11 Select Yes and then select OK on the next screen The virtual drive is created ...

Страница 151: ...n 1 Select Free Capacity for Select Drives From 2 Select Select Drive Groups 3 Select the Drive Group to be additionally created for Choose Drive Group and then select Enabled 4 Select Apply Changes and then OK on the next screen Note You may select either of the upper or lower Apply Changes which is provided at two locations ...

Страница 152: ...al Drive Size Specify the capacity of the virtual drive 5 3 Virtual Drive Size Unit Specify the unit MB GB TB used for Virtual Drive Size Important The Disk WC and Read Ahead settings reflect the original Drive Group setting If you change these settings the original Drive Group setting is also changed 6 When all the settings are completed select Save Configuration Note You may select either of the...

Страница 153: ... drive is created 5 Select Virtual Drive Management and then Manage Virtual Drive Properties and check the Virtual Drive information on the following screen When multiple virtual drives are created for Select Virtual Drive select the virtual drive you want to check 6 Press the Esc key to return to the previous screen and then select Select Virtual Drive Operations ...

Страница 154: ...d for Select Virtual Drive Important Data is lost after initialization Take extreme care to select the correct Virtual Drive 8 Select Virtual Drive Operation and then select Fast Initialization on the following screen Important In the UEFI mode Full Initialization on the LSI Software RAID Configuration Utility takes long time so do not select it ...

Страница 155: ...art the Fast Initialization Note Fast Initialization completes in a few seconds or several tens of seconds 10 Select OK 11 Install the OS You don t need to install the OS if the created virtual drive is not for booting the OS After the OS is installed install Universal RAID Utility For more information about how to install refer to the User s Guide that comes with this server ...

Страница 156: ...versal RAID Utility User s Guide Important In the UEFI mode Check Consistency on the LSI Software RAID Configuration Utility takes long time Run Check Consistency from the Universal RAID Utility on the OS Inconsistency may be detected at the first time of the consistency check but there is no problem Note For RAID0 running Check Consistency is not required 13 Press the Esc key to return to the TOP...

Страница 157: ...Utility on the OS If you need to run Rebuild on the LSI Software RAID Configuration Utility follow the procedure below 1 Replace a physical device and then restart the server 2 Run LSI Software RAID Configuration Utility 3 From the TOP menu select Drive Management and then Select Drive Operations The following screen appears 4 Confirm that the target physical device is displayed for Select Drive R...

Страница 158: ...en select Rebuild 6 Select Start Operation 7 Select OK to start the rebuild Note The status of Operation Progress is not automatically updated If you want to update the progress status press the Esc key to return to the previous screen and then select Select Virtual Drive Operations again 8 Exit LSI Software RAID Configuration Utility ...

Страница 159: ... Connect a physical device for hot sparing and then turn on the server 2 Run LSI Software RAID Configuration Utility 3 On the TOP menu screen select Drive Management The following screen appears Connect the physical device Run LSI Software RAID Configuration Utility Configure HotSpare Exit LSI Software RAID Configuration Utility ...

Страница 160: ...5 RAID System Configuration Express5800 R120f 2E T120f Maintenance Guide 160 Chapter 2 Useful Features 4 Select Select Drive and then select the physical device for hot sparing 5 Select Drive Operation ...

Страница 161: ...00 R120f 2E T120f Maintenance Guide 161 Chapter 2 Useful Features 6 Select Assign Global Hot Spare Drive 7 Select Start Operation and then select OK 8 Return to the TOP menu screen 9 Select Drive Management 10 Select View Global Hot Spare ...

Страница 162: ...ance Guide 162 Chapter 2 Useful Features 11 Confirm that a hot spare drive has been created 12 Exit LSI Software RAID Configuration Utility Note To cancel the HotSpare setting select Drive Management Select Drive Operations and then select Unassign Hot Spare Drive ...

Страница 163: ...e LSI Software RAID Configuration Utility takes long time Run Check Consistency from the Universal RAID Utility on the OS For RAID0 running Check Consistency is not required 1 From the TOP menu of LSI Software RAID Configuration Utility select Virtual Drive Management Run LSI Software RAID Configuration Utility Run Check Consistency Exit LSI Software RAID Configuration Utility ...

Страница 164: ...figuration Express5800 R120f 2E T120f Maintenance Guide 164 Chapter 2 Useful Features 2 Select Select Virtual Drive Operations 3 Select the target virtual drive for Select Virtual Drive 4 Select Virtual Drive Operation ...

Страница 165: ...5 RAID System Configuration Express5800 R120f 2E T120f Maintenance Guide 165 Chapter 2 Useful Features 5 Select Check Consistency 6 Select Start Operation 7 Select Yes on the next screen ...

Страница 166: ...on for Virtual Drive Operation changes to Check Consistency on the Select Virtual Drive Operations screen and the progress is displayed at the bottom of the screen Note The status of Operation Progress is not automatically updated Press the Esc key to return to the screen to the upper position once the progress status is updated when the mode enters Select Virtual Drive Operations ...

Страница 167: ...t OK 2 Place Drive Online Use this feature to forcibly put a physical device in the FAIL status online From the TOP menu select Drive Management and then Select Drive Operations confirm that the target physical device is displayed for Select Drive select Drive Operation Place Drive Online and then Start Operation When a confirmation message is displayed select Yes and then select OK 3 Rebuild Rate...

Страница 168: ...k Array Physical Drive Physical Device Physical Device Drive Group Disk Array Disk Array Tips raidcmd is a command that Universal RAID Utility provides See Universal RAID Utility User s Guide for more information 2 Number and ID The number to manage each component of RAID Controller of Universal RAID Utility is different to LSI Software RAID Configuration Utility See the table below See Universal ...

Страница 169: ...o 100 High 8 to 14 Middle 0 to 7 Low Consistency Check Priority Chk Const Rate LSI Software RAID Configuration Utility 15 to 100 High 8 to 14 Middle 0 to 7 Low Setting level of Universal RAID Utility and the setting value Item Setting level of Universal RAID Utility Setting value Rebuild Priority Rebuild Rate LSI Software RAID Configuration Utility High 20 Middle 10 Low 5 Consistency Check Priorit...

Страница 170: ...iewer raidcmd Controller RAID Controller RAID Controller Virtual Drive Logical Drive Logical Drive Drive Group Disk Array Disk Array Drive Physical Device Physical Device Tips raidcmd is a command provided by Universal RAID Utility See Universal RAID Utility User s Guide for details 2 Numbering The numbers indicating RAID controller information differ between Off line Utility and Universal RAID Ut...

Страница 171: ... Utility Rebuild priority 80 to 100 High 31 to 79 Middle 0 to 30 Low Patrol Read priority 80 to 100 High 31 to 79 Middle 0 to 30 Low Consistency Check priority 80 to 100 High 31 to 79 Middle 0 to 30 Low Setting values of Universal RAID Utility Item Levels of Universal RAID Utility Setting values Rebuild priority High 90 Middle 50 Low 10 Patrol Read priority High 90 Middle 50 Low 10 Consistency Che...

Страница 172: ... running Windows Autorun Menu shown in Chapter 2 5 2 Menus of EXPRESSBUILDER 4 Autorun Menu will appear Be sure that the CD DVD drive has no disc restart the server and press F3 key at the following POST message Internal Flash Memory Press F2 SETUP F3 Internal Flash Memory F4 ROM Utility F12 Network When EXPRESSBUILDER starts from Internal Flash Memory Boot Selection Menu shown in Chapter 2 5 2 Me...

Страница 173: ...lation is chosen or no key is pressed Home Menu shown in 2 Home Menu will appear Tool Menu shown in 3 Tool Menu will appear when you choose Tool menu Normal mode The screen is displayed on local console Choose this mode usually if you want to run Tool menu You can operate EXPRESSBUILDER remotely by using BIOS Console Redirection when choosing Tool menu Redirection mode The menu items and the tools...

Страница 174: ...ure RAID arrays without installing Windows choose Manual Selection in step 1 b Utilities Runs utilities in EXPRESSBUILDER See Chapter 2 6 3 Utilities in EXPRESSBUILDER for details c Versions Shows the versions of software and drivers in EXPRESSBUILDER d Exit Closes EXPRESSBUILDER and then shut down or restart the server 3 Tool Menu Test and diagnostics Return to the previous menu The system diagno...

Страница 175: ...er to read the manuals b Versions Shows the versions of software and drivers in EXPRESSBUILDER c Integrated Installation Installs several applications or Starter Pack easily If a computer running the menu is not this server or the logon user does not have the administrator privilege this item is grayed out d Applications Installs or runs applications individually e Files for Setup Creates a file f...

Страница 176: ...eature only for utilities provided by NEC Note Do not run the file provided by a third party 4 Internal Flash Memory available only on DVD Manages Internal Flash Memory with the following commands a Initialize Clears the data in Internal Flash Memory and initializes formats it Note that all data in Internal Flash Memory is deleted b Update Copies the data of the EXPRESSBUILDER DVD or other media t...

Страница 177: ...ing the management LAN port to your network enables you to do the following from a remote site by using a web browser and SSH client Managing the server Operating KVM keyboard video and mouse from a remote console Accessing a CD ROM DVD ROM floppy disk ISO image or USB flash drive in a remote console N8115 04 Remote KVM and Media License are required to activate these features To actualize these f...

Страница 178: ...Maintenance Guide 178 Chapter 2 Useful Features 8 NEC ESMPRO 8 1 NEC ESMPRO ServerAgentService for Windows For details of NEC ESMPRO ServerAgentService for Windows see NEC ESMPRO ServerAgentService Installation Guide Windows in EXPRESSBUILDER ...

Страница 179: ...2 NEC ESMPRO Manager NEC ESMPRO Manager can remotely control and monitor the hardware and the RAID system of the server To use these features install the bundle software for the server such as NEC ESMPRO ServerAgentService For details see NEC ESMPRO Manager Installation Guide or online help ...

Страница 180: ...y You can specify configuration data to the BMC of the server by using this utility For details see Server Configuration Utility User s Guide in EXPRESSBUILDER 8 5 NEC ExpressUpdate Agent You can easily download manage and update the firmware or the software installed in this server by using NEC ExpressUpdate Agent For details see NEC ExpressUpdate Agent Installation Guide in EXPRESSBUILDER Tips R...

Страница 181: ...llect the server information Product Info for maintenance by using this utility 9 1 Usage Run the stdclct collect exe contained in the installation folder of this utility This utility is usually installed to the C ezclct folder The log folder is created in the stdclct folder and Product Info is stored in a compressed zip file Tips Log on to Windows with an account that has an administrator privile...

Страница 182: ... 178 RAID Controller 2GB RAID 0 1 5 6 N8103 179 RAID Controller 2GB RAID 0 1 5 6 For information about installing Universal RAID Utility see Universal RAID Utility in Installation Guide Windows See Universal RAID Utility User s Guide in EXPRESSBUILDER for more information about operating instructions and features 10 1 Creating Logical Drive of RAID 6 Four or more physical devices are required to c...

Страница 183: ...120f Maintenance Guide 183 Chapter 2 Useful Features 11 Express Report Service Express Report Service HTTPS For details about Express Report Service Express Report Service HTTPS see Express Report Service Express Report Service HTTPS Installation Guide Windows in EXPRESSBUILDER ...

Страница 184: ... MG Express5800 R120f 2E T120f Maintenance Guide 184 Chapter 2 Useful Features 12 Express Report Service MG For details about Express Report Service MG see Express Report Service MG Installation Guide Windows in EXPRESSBUILDER ...

Страница 185: ... a list of error messages for errors detected by the power on self test POST 2 List of Windows Event Logs Shows a list of Windows event logs 3 Accessing Data for Electrical Power Temperature and Processor Utilization Describes how to check power consumption in watts intake temperature and logical processor utilizations 4 Glossary 3 3 ...

Страница 186: ...1 has been disabled AE02 CPU1_DIMM2 has been disabled Press F1 to resume F2 to setup Messages indicating a memory error in this example the message indicates that CPU1_DIMM1 and CPU1_DIMM2 have failed and that DIMM1 has been forcibly started up The next table lists the error messages and the actions to solve the problem Tips Write down the displayed messages and beep patterns before contacting you...

Страница 187: ...les representative This error message also appears when lithium battery is removed 8007 SETUP Menu Password cleared by Jumper The setup utility password was cleared using the jumper 8020 BIOS update error BIOS update failed Try BIOS update again If the same error is detected repeatedly contact your sales representative 8021 Recovery jumper is set but recovery images is not found Recovery jumper is...

Страница 188: ...n CPU1_DIMM6 An error was detected in CPU1_DIMM6 A007 Memory Error detected in CPU1_DIMM7 An error was detected in CPU1_DIMM7 A008 Memory Error detected in CPU1_DIMM8 An error was detected in CPU1_DIMM8 A00D Memory Error detected in CPU2_DIMM1 An error was detected in CPU2_DIMM1 A00E Memory Error detected in CPU2_DIMM2 An error was detected in CPU2_DIMM2 A00F Memory Error detected in CPU2_DIMM3 An...

Страница 189: ...ected CPU1_DIMM4 has been disabled AE05 CPU1_DIMM5 has been disabled A memory error was detected CPU1_DIMM5 has been disabled AE06 CPU1_DIMM6 has been disabled A memory error was detected CPU1_DIMM6 has been disabled AE07 CPU1_DIMM7 has been disabled A memory error was detected CPU1_DIMM7 has been disabled AE08 CPU1_DIMM8 has been disabled A memory error was detected CPU1_DIMM8 has been disabled A...

Страница 190: ...d An error in CPU2_DIMM3 was detected but because all memory is currently disabled this DIMM was forcibly enabled AE90 CPU2_DIMM4 with error is enabled An error in CPU2_DIMM4 was detected but because all memory is currently disabled this DIMM was forcibly enabled AE91 CPU2_DIMM5 with error is enabled An error in CPU2_DIMM5 was detected but because all memory is currently disabled this DIMM was for...

Страница 191: ... 02 PCIe Link Failure Connection failure of PCIe bus was detected on PCI slot 02 B213 PCI Slot 03 PCIe Link Failure Connection failure of PCIe bus was detected on PCI slot 03 B214 PCI Slot 04 PCIe Link Failure Connection failure of PCIe bus was detected on PCI slot 04 B215 PCI Slot 05 PCIe Link Failure Connection failure of PCIe bus was detected on PCI slot 05 B231 PCI Slot 01 PCIE Link Width Erro...

Страница 192: ...th SMBus device Error detected An error was detected on 8th SM Bus Contact your sales representative C101 BMC Memory Test Failed An error was detected on BMC Unplug the power cord wait for at least 30 seconds then restart the server If the same error is detected repeatedly contact your sales representative C102 BMC Firmware Code Area CRC check Failed C103 BMC core hardware failure C104 BMC IBF or ...

Страница 193: ...erboard If the same error is detected repeatedly contact your sales representative C11E Communication with BMC was failed in previous boot Communication with BMC was failed in previous boot Unplug the power cord wait for 30 seconds and restart the server If the same error is detected repeatedly contact your sales representative C11F Backup Data of BMC Mezzanine card has corrupted Inconsistency was...

Страница 194: ...System power consumption is out of range in PSUs System power consumption exceeds the power output capacity limit C322 No information for system power consumption check No information is acquired in checking system power consumption C326 Configuration mismatch for Advanced Fan control support Advanced Fan Control feature is disabled in this hardware configuration Enable this feature in adequate co...

Страница 195: ...No DIMMs are installed Check if DIMMs are properly installed If the same error persists contact your sales representative 1 5 2 1 No processors are installed Check if processor is properly installed If the same error persists contact your sales representative 1 5 4 4 Power on is inhibited Contact your sales representative 1 POST detected an error 4 Initializing the BIOS executable module failed 5 ...

Страница 196: ...ill disappear when SETUP operation is completed Waiting for normal temperature A temperature abnormality was detected inside the server Lower the room temperature or turn off the power to cool the server to room temperature before starting up the server If this abnormality continues to occur check if a fan has failed If the same error still continues to occur contact your representative BIOS Recov...

Страница 197: ...rocessor2 Voltage Upper Critical Processor Voltage Lower Non Critical Processor Voltage Upper Non Critical Processor Voltage Lower Critical Processor Voltage Upper Critical BaseBoard Voltage Lower Non Critical BaseBoard Voltage Upper Non Critical BaseBoard Voltage Lower Critical BaseBoard Voltage Upper Critical Baseboard Temperature1 Lower Non Critical A temperature abnormality was detected The co...

Страница 198: ...Temperature Upper Non Critical CPU2 DIMM Area Temperature Lower Critical CPU2 DIMM Area Temperature Upper Critical Processor1 Thermal Control Upper Non Critical Processor1 Thermal Control Upper Critical Processor2 Thermal Control Upper Non Critical Processor2 Thermal Control Upper Critical DUMP Request The dump button was pressed Wait until collecting the memory dump data has finished Power Supply...

Страница 199: ...or occurred for CPU1 DIMM7 CPU1 DIMM8 Uncorrectable Error An unrecoverable error occurred for CPU1 DIMM8 CPU2 DIMM1 Uncorrectable Error An unrecoverable error occurred for CPU2 DIMM1 CPU2 DIMM2 Uncorrectable Error An unrecoverable error occurred for CPU2 DIMM2 CPU2 DIMM3 Uncorrectable Error An unrecoverable error occurred for CPU2 DIMM3 CPU2 DIMM4 Uncorrectable Error An uncorrectable error occurre...

Страница 200: ... sales representative Node Manager Firmware Flash Erase Error Node Manager Firmware Flash Corrupted Node Manager Internal Error Node Manager can t communicate BMC Node Manager Manufacturing Error Node Manager Persistent Storage Integrity Error Drive 0 Fault Operation was performed during hard disk drive failure Turn off the power wait for at least 30 seconds and restart the server If this does not...

Страница 201: ...er Non Critical A fan alarm was detected The cooling fan has failed or is clogged Contact your sales representative System Rear FAN2 Lower Non Critical System Rear FAN3 Lower Non Critical System Rear FAN4 Lower Non Critical System Rear FAN5 Lower Non Critical System Rear FAN6 Lower Non Critical System Rear FAN7 Lower Non Critical System Rear FAN8 Lower Non Critical System Front FAN1 Lower Non Crit...

Страница 202: ...ss Windows Server 2012 R2 System Log 2 ipoib6x Error Failed to initialize Mellanox ConnectX IPoIB Adapter When applying Starter Pack or driver for InfiniBand card for the first time after OS installation with N8104 146 147 InfiniBand card connected If Event ID 1 Mellanox ConnectX 3 IPoIB Adapter device has been successfully initialized and enabled is logged after this event there is no problem in ...

Страница 203: ...e as a time source because of a DNS resolution error on time windows com 0x9 NtpClient will try again in 15 minutes and double the reattempt interval thereafter When installing an OS starting system or applying Starter Pack If it is not registered after connecting to the Internet there is no problem with system operation 153 disk Warning The I O operation at the logical block address for disk was ...

Страница 204: ...ct system operation 1014 Microsoft Windows Security SPP Error Failed to obtain end user license hr 0x80072EE7 When installing an OS If this event is logged only when installing an OS and does not occur repeatedly there is no problem in system operation 1015 Microsoft Windows Security SPP Warning Detailed information of HRESULT Returned hr 0xC004F022 original hr 0x80049E00 When installing an OS If ...

Страница 205: ...ystem Log 4 b57nd60a Warning Broadcom NetXtreme Gigabit Ethernet xx The network link is down Check to make sure the network cable is properly connected When installing an OS starting system or applying Starter Pack This event does not affect system operation 4 l2nd Warning Broadcom BCM57810 xx The network link is down Check to make sure the network cable is properly connected When installing an OS...

Страница 206: ...y there is no problem in system operation 7023 Service Control Manager Error The Network List Service terminated with the following error The device is not ready When installing an OS If this event is logged only when installing an OS and does not occur repeatedly there is no problem in system operation 7023 Service Control Manager Error The IP Helper service terminated with the following error Th...

Страница 207: ...lling an OS and does not occur repeatedly there is no problem in system operation 200 Microsoft Windows DeviceSetupManager Warning A connection to the Windows Update service could not be established When running the system If it is not registered after the Internet connection is established there is no problem with system operation 201 Microsoft Windows DeviceSetupManager Warning A connection to t...

Страница 208: ...stem operation Windows Server 2008 R2 System Event Log 1 iScsiPrt Error Initiator failed to connect to the target Target IP address and TCP Port number are given in dump data When Windows Server 2008 R2 is operating while iSCSI is recognized Go to the following Microsoft website for details http support microsoft com kb 976072 en us 4 b57nd60a Warning Broadcom NetXtreme Gigabit Ethernet xx The net...

Страница 209: ...0 00 00 00 3C 00 00 00 0050 00 00 00 00 80 A2 BA 86 o 0058 00 00 00 00 08 B0 BD 86 0060 00 00 00 00 00 00 00 00 0068 00 00 00 00 00 00 00 00 0070 00 00 00 00 00 00 00 00 0078 00 00 00 00 00 00 00 00 0080 00 00 00 00 00 00 00 00 0088 00 00 00 00 00 00 00 00 11 iANSMiniport Warning Adapter link down Intel R When starting system This event is logged at system startup if a team is configured with Inte...

Страница 210: ...is account is privileged and the provider may cause a security violation if it does not correctly impersonate user requests Upon applying Starter Pack This event does not affect system operation 1015 Microsoft Windows Security SPP Warning Description Detailed information of HRESULT Returned hr 0xC004F022 original hr 0x80049E00 When installing an OS Unless the application event is registered after ...

Страница 211: ...vices Logs Microsoft Windows Kernel EventTracing Admin 2 Microsoft Windows Kernel EventTracing Error Session failed to start with the following error 0xC000000D When running an OS for the first time This event does not affect system operation 3 Microsoft Windows Kernel EventTracing Error Session Microsoft Windows Setup stopped due to the following error 0xC000000D When running an OS for the first ...

Страница 212: ... When installing an OS This event does not affect system operation 10 VDS Dynamic Provider Error The provider failed while storing notifications from the driver The Virtual Disk Service should be restarted hr 80042505 When installing an OS Go to the following Microsoft website for details http support microsoft com kb 948275 en us 134 Microsoft Windows Time Service Warning NtpClient was unable to ...

Страница 213: ...ror number When installing an OS This event does not affect system operation Application Event Log 63 Microsoft Windows WMI Warning A provider IntelEthernetDiag has been registered in the Windows Management Instrumentation namespace Root CIMv2 to use the LocalSystem account This account is privileged and the provider may cause a security violation if it does not correctly impersonate user requests...

Страница 214: ...tes DWORD of the Data section contains the status code When installing an OS If the computer has CPU containing more than 32 cores the system log may report many errors Go to the following Microsoft website for details http support microsoft com kb 925104 2019 EvntAgnt Error SNMP Event Log Extension Agent did not initialize correctly When installing an OS This event does not affect system operatio...

Страница 215: ... by using Visual Basic Script named as Power vbs Start Script Option Explicit Prepare for IPMI Driver Dim osvc oclass Dim oinstance oipmi set osvc getobject winmgmts root wmi set oclass osvc get microsoft_ipmi for each oinstance in osvc instancesof microsoft_ipmi set oipmi oinstance next Format the IPMI command request Dim oinparams set oinparams oclass methods_ requestresponse inparameters oinpar...

Страница 216: ...nstance next Get SDR Repository Info Dim oinparams set oinparams oclass methods_ requestresponse inparameters Get SDR Repository Info oinparams networkfunction ha oinparams lun 0 oinparams responderaddress h20 oinparams command h20 oinparams requestdatasize 0 Fire IPMI Command Dim outparams Dim i RecordCount set outparams oipmi execmethod_ requestresponse oinparams RecordCount outparams ResponseDa...

Страница 217: ... rc_ms 20 14 oinparams requestdatasize 6 set outtmp oipmi execmethod_ requestresponse oinparams units1 outtmp ResponseData 3 Select Case outtmp ResponseData 4 case 0 units2 unspecified case 1 units2 degrees C case 6 units2 Watts case else units2 Refer to IPMI Specification Type 0x _ hex outtmp ResponseData 4 End Select Get Sendor Reading Dim sensorData rawData currentValue oinparams networkfunctio...

Страница 218: ...unction ha oinparams lun 0 oinparams responderaddress h20 oinparams command h23 oinparams requestdata array rv_ls rv_ms rc_ls rc_ms 48 idlength oinparams requestdatasize 6 set outsdridstring oipmi execmethod_ requestresponse oinparams tmpMessage ID String For j 3 to idlength 2 tmpMessage tmpMessage Chr outsdridstring ResponseData j Next WScript Echo tmpMessage End Sub End Script Execution example ...

Страница 219: ...dEnum _ objWMIService Win32_PerfFormattedData_PerfOS_Processor objectSet objRefresher Refresh Dim first first true Do For each intProcessorUse in objProcessor If first Then If intProcessorUse Name _Total Then first false End If else Wscript Echo Proc intProcessorUse Name _ PercentProcessorTime _ intProcessorUse PercentProcessorTime End If Next Wscript Sleep 30 1000 sleep 30 1000ms objRefresher Ref...

Страница 220: ...ard You can start EXPRESSBUILDER from it without DVD when pressing F3 key during POST NEC ESMPRO Standard software for the server management This consists of several applications for managing or monitoring NEC ESMPRO Agent Software for monitoring the server This works with NEC ESMPRO Manager and resides as the OS service NEC ESMPRO Agent Extension Software for performing the scheduled operations T...

Страница 221: ...2E T120f Maintenance Guide December 2014 NEC Corporation 7 1 Shiba 5 Chome Minato Ku Tokyo 108 8001 Japan NEC Corporation 2014 The contents of this manual may not be copied or altered without the prior written permission of NEC Corporation ...