System Specifications
___________________________________________________________________________________
Document Revision 3
Electra Elite IPK II
5.2
Cabling Precautions
5.2.1
Cable Placement
When selecting cables and Main Distribution Frame (MDF), future
expansion or assignment changes should be considered. Avoid
running cables in the following places:
J
A place exposed to wind or rain.
J
A place near heat radiating equipment or where the quality of
station cable covering could be affected by gases and
chemicals.
J
An unstable place subject to vibration.
Table 3-8 Cable Connection Between the Analog Port and
the Single Line Equipment
Connected Equipment
Cable
Maximum Distance or
Impedance Between
Equipment and Telephone
AD(A)-R/AD(A)-2R Unit
Twisted Pair
10 feet
ADA(2)-W Unit
Twisted Pair
10 feet
AP(A)-R or AP(R)-R Unit
Twisted Pair
50 feet
APA-U Unit or APR-U Unit
Twisted Pair
50 feet
OPX(2)-U( ) ETU
Twisted Pair
1,600 ohms
SLI(4)/(8)-U( ) ETU
Twisted Pair
300 ohms
SLIB(4)/SLIE(4)-U10 ETU
Twisted Pair
300 ohms
SLTII(1)-U10 ADP
Twisted Pair
50 feet
Mixing digital and analog ports through the same 25-pair cable runs
is not recommended.
Table 3-9 Cabling Requirements
Connected Equipment
Cable
External Amplifier
Hi-Fi Shielded Audio Cable
Music on Hold and Background Music
Sources
Hi-Fi Shielded Audio Cable
ITH Cabling
Cat 5 Straight Data Network cable
100 meters maximum distance
Содержание ELECTRA ELITE IPK II
Страница 2: ......
Страница 3: ...SYSTEM HARDWARE MANUAL INT 1076 IPK II DOCUMENT REVISION 3 VERSION 2000...
Страница 4: ......
Страница 6: ......
Страница 10: ...THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 641: ...SYSTEM HARDWARE MANUAL NECUnified Solutions Inc Document Revision 3...
Страница 642: ......