24
10.
Close the lever that was opened in Step 7 to secure the BBU.
Disk array controller
7
Old BBU
New BBU
11.
Reinstall the disk array controller in the PCI (PCI Express) slot of the server, and secure it with
screws.
12.
Reconnect all the cables to the disk array controller.
13.
Replace the side cover and plug the power cords. Power on the server.
14.
Once the OS has booted, check whether the BBU is recognized correctly. Refer to "2. Utility Check"
in "Chapter 2 Installing the BBU."
Notice
The battery cell you have purchased is not charged at all. In this case,
the [Current Write Policy] in the [Properties] of the [Logical] tab is
indicated as "Write Through" on MSM.
You can check the charge status of the battery cell by selecting [Relative
State of Charge] or [Absolute State of Charge] in [Physical] tab
→
[Properties] on MSM.
Check
The battery cell is recyclable. Contact your service representative for proper
disposal.
Содержание BBU
Страница 1: ... User Guide SA2500 WA2500 Battery Backup Unit for 8480E and 8408E DACs ...
Страница 2: ...This page is deliberately left empty ...
Страница 21: ...18 1 4 Connecting the Cable Connect the cable to the battery cell and the memory module ...
Страница 28: ...This page is deliberately left empty ...
Страница 29: ... ...