Figure 35: Embedded Workbench Linker Configuration
Now after everything has been setup correctly it’s time to compile and link the demonstration project. Close
the Options menu and select “Rebuild All” from the “Project” menu. If the project is compiled and linked
without errors or warnings it can now be downloaded to the
78K0R Save It! board
and debugged.
To start the IAR C-SPY debugger select the option “Debug” from the “Project” menu or press the ( )
“Debugger” button.
When first starting the debugger connection, after building the project, it is necessary to set up the right
connection settings. Please take care that the following settings are chosen:
•
ID code = FFFFFFFFFFFFFFFFFFFF
•
Main clock = External 20.00 MHz
•
Sub clock = External 32.768KHz
•
Target connect = TOOL0+TOOL1
_______________________________________________________________________________________________
User’s Manual
U19663EE1V0UM00
39