4-32
Menu Description
+Adapter
Set disk array controller
+Clear Configuration
Clear configuration
*1
FlexRAID PowerFail
Set whether to restart after rebuilding
*2
Fast Initialization
Set high-speed initialization
*3
Disk Spin up Timing
Set hard disk spin-up
*4
Cache Flush Timing
Set cache flush timing
*5
Rebuild Rate
Set rebuild rate
*6
Alarm Control
Set alarm sound (ON / OFF)
+Other Adapter Information
Board information display (FW version, etc.)
•
FW Supports
FW type
•
FW Ver
FW version
•
BIOS Ver
BIOS version
•
DRAM
Memory capacity
•
Adapter Type
Board series NO.
+Factory Default
Set default value
*7
Disable (Enable) BIOS
Set BIOS Enable / Disable
+Battery Information Battery
information
•
Backup Module
Existence of battery module
•
Battery Pack
Existence of battery pack
•
Temperature
Battery temperature
•
Voltage
Battery voltage
•
Fast Charging
Set fast charging status
•
No of Cycles
The number charge cycle
+Reset Battery Charge Counter
Clear battery charge counter
+Other Adapter Options
Adapter detailed options
*8
Emulation
Set control mode
*9
Auto Rebuild
Set auto rebuilding Enable / Disable
•
Initiator ID
Indicate Initiator ID No.
*10
Cluster Mode
Set cluster mode
*11
Multiple PCI Delayed Trans
Set PCI bus bridge
*12
Force Boot
Forced setting of configuration information(HDD)
*13
Coercion Algorithm
Setting parameter for maximum hard disk capacity
Abort BI & CC Activities
Abort Background initialize or Check Consistency
*14
CC Restoration
Select CC Restoration mode
*15
Temporary Offline RAID
Set Temporary offline Enable / Disable
+Logical Drive
Logical drive operation
+Logical Drives
Select logical drive
+Initialize
Initialize logical drive
+Check Consistency
Check logical drive redundancy
+View/Update Parameters
Display logical drive information
•
RAID
Display RAID level
•
SIZE
Display logical drive capacity
•
Stripe SIZE
Display stripe size
+
√
Write Policy
Set write mode
+
√
Read Policy
Set read mode
+
√
Cache Policy
Set cache mode
+
√
FlexRAID Virtual Sizing
Set virtual sizing Enable / Disable
*Do not set to Enable
•
#Stripes
Display stripe size
•
State
Display logical drive status
+Physical Drive
Physical drive menu
+Physical Drive Selection Menu
Physical drive operation
+Rebuild
Perform
rebuilding
+Format
Perform low level format
*Do not use
+Make Online
Set the disk online
Содержание 140He
Страница 1: ...User s Guide Express5800 140He...
Страница 2: ......
Страница 4: ...This page is intentionally left blank...
Страница 36: ...2 8 Internal View 1 2 4 3 1 Power supply cage 2 Non hot plug PCI slot 3 Hot plug PCI slot 4 Fan bay...
Страница 60: ...2 32 This page is intentionally left blank...
Страница 170: ...5 20 This page is intentionally left blank...
Страница 193: ...6 23 Linux Enter the following command to start the program cd usr BmcOnlineUpdate BmcOnlineUpdate...
Страница 195: ...6 25 Windows 2000 1 Select Setting Control Panel Add or Remove Programs 2 Click BmcOnlineUpdate...
Страница 328: ...B 6 This page is intentionally left blank...
Страница 342: ...D 10 This page is intentionally left blank...
Страница 354: ...E 12 This page is left intentionally blank...
Страница 359: ......